40
KX-TG8011MES/KX-TGA800MES
9.2.
Troubleshooting by Symptom (Base Unit )
If your unit has below symptoms, follow the instructions in remedy column. Remedies depend on whether you have DECT tester
(*1) or not.
Note:
(*1) A general repair is possible even if you don’t have the DECT tester because it is for confirming the levels, such as Acoustic
level in detail.
(*2) Refer to
Check Point (Base Unit)
(P.40)
9.2.1.
Check Point (Base Unit)
Please follow the items below when BBIC or EEPROM is replaced.
Note:
After the measuring, suck up the solder of TP.
*:
PC Setting
(P.51) is required beforehand.
The connections of simulator equipment are as shown in
Adjustment Standard (Base Unit)
(P.53).
Items
Check
Point
Procedure
Check or
Replace Parts
(
A
) 3.0 V Supply Confirma-
tion
VDD3
1. Confirm that the voltage between test point VDD3 and GND is 3.0 V ± 0.2 V.
IC1, C31, C32,
R38, R39, C36,
F1, C37, D1
(
B
) 1.8 V Supply Confirma-
tion
VDD1
1. Confirm that the voltage between test point VDD1 and GND is 1.8 V ± 0.1 V. Q8, C75, C614,
C61
,
C64, C68,
IC7
(
C
) Charge Pump
2.5V Supply Confirma-
tion
VDD5
1. Confirm that the voltage between test point VDD5 and GND is 2.5 V -0.1/+0.3
V.
IC7, C625
(
D
) Charge Pump
3.0V Supply Confirma-
tion
VDD4
1. Confirm that the voltage between test point VDD4 and GND is 3.0 V ± 0.2 V.
IC7, C422
(
E
)*
BBIC Confirmation
-
1. BBIC Confirmation (Execute the command “getchk”).
2. Confirm the returned checksum value.
Connection of checksum value and program number is shown below.
IC7, X1, R77,
R79, R80
(
F
)* EEPROM Confirmation
-
1. EEP-ROM Confirmation (Execute the command “ChkTG7300XXrevYY.bat”).
XX: country code
YY: revision number
2. Confirm the returned checksum value.
3. The checksum is displayed in the last output line.
Note:
“XX”, “YY”, and “checksum” vary depending on the country version. You can find
them in the batch file, PQZZ- mentioned in
JIG and PC
(P.51).
IC7, RA402,
C51, R657,
IC401
(
G
)* BBIC Clock Adjustment
CLK
VDD4
1. Input Command “ sendchar WWD ff 48 IC 8006”
2. Confirm that the voltage between testpoint VDD4 and GND is less than 1.0 V.
3. Input Command “ sendchar sfr”, then you can confirm the current value.
4. Check X’tal Frequency. (10.368 MHz ± 100 Hz).
5. If the frequency is not 10.368MHz ± 100Hz, adjust the frequency of CLK exe-
cuting the command “sendchar sfr xx xx (where xx is the value)” so that the
reading of the frequency counter is 10.368000 MHz ± 5 Hz.
X1, IC7, R430,
R425, C305
Summary of Contents for KX-TG8011MES
Page 2: ...2 KX TG8011MES KX TGA800MES ...
Page 13: ...13 KX TG8011MES KX TGA800MES 4 5 Signal Route ...
Page 16: ...16 KX TG8011MES KX TGA800MES 6 2 4 Panasonic Ni MH Battery Performance supplied batteries ...
Page 17: ...17 KX TG8011MES KX TGA800MES 7 Operating Instructions 7 1 Programmable Settings ...
Page 19: ...19 KX TG8011MES KX TGA800MES 7 3 Dialling Mode Tone Pulse 7 4 Error Messages ...
Page 20: ...20 KX TG8011MES KX TGA800MES 7 5 Troubleshooting Cross Reference For Service Hint P 22 ...
Page 21: ...21 KX TG8011MES KX TGA800MES ...
Page 22: ...22 KX TG8011MES KX TGA800MES 7 6 For Service Hint Cross Reference Battery Charge P 15 ...
Page 23: ...23 KX TG8011MES KX TGA800MES 8 Service Mode 8 1 Engineering Mode 8 1 1 Base Unit ...
Page 25: ...25 KX TG8011MES KX TGA800MES 8 1 2 Handset ...
Page 32: ...32 KX TG8011MES KX TGA800MES Cross Reference Check Point Base Unit P 40 ...
Page 34: ...34 KX TG8011MES KX TGA800MES Cross Reference Check Point Handset P 44 ...
Page 49: ...49 KX TG8011MES KX TGA800MES 10 1 2 Handset ...
Page 50: ...50 KX TG8011MES KX TGA800MES 10 2 How to Replace the Handset LCD ...
Page 69: ...69 KX TG8011MES KX TGA800MES Memo ...
Page 74: ...74 KX TG8011MES KX TGA800MES Memo ...
Page 81: ...81 KX TG8011MES KX TGA800MES 15 3 Accessories and Packing Materials 15 3 1 KX TG8011MES ...