![Panasonic KX-TG7100HGS Service Manual Download Page 32](http://html1.mh-extra.com/html/panasonic/kx-tg7100hgs/kx-tg7100hgs_service-manual_4227824032.webp)
32
KX-TG7100HGS/KX-TG7102HGS/KX-TGA711FXS
9.2.
Troubleshooting by Symptom (Base Unit and Charger Unit)
If your unit has below symptoms, follow the instructions in remedy column. Remedies depend on whether you have DECT tester
(*1) or not.
Note:
(*1) A general repair is possible even if you don’t have the DECT tester because it is for confirming the levels, such as Acoustic
level in detail.
(*2) Refer to
Check Point (Base Unit)
(P.32)
9.2.1.
Check Point (Base Unit)
Please follow the items below when BBIC or EEPROM is replaced.
Note:
After the measuring, suck up the solder of TP.
*:
PC Setting
(P.45) is required beforehand.
The connections of simulator equipments are as shown in
Adjustment Standard (Base Unit)
(P.47).
Items
Check
Point
Procedure
Check or
Replace Parts
(
A
) 3.3 V Supply Confirma-
tion
VDD3
1. Confirm that the voltage between test point VDD3 and GND is 3.3 V ± 0.2 V.
IC1, C31, C32,
R38, R39, C36,
C37
(
B
) 2.5 V Supply Confirma-
tion
VDD2
1. Confirm that the voltage between test point VDD2 and GND is 2.5 V ± 0.2 V.
Q9, C70, C71
(
C
)* 1.8 V Supply Confirma-
tion
VDD1
1. Confirm that the voltage between test point VDD1 and GND is 1.8 V ± 0.1 V.
Q8, R72, D12,
C68
(
D
)*
BBIC Confirmation
-
1. BBIC Confirmation (Execute the command “getchk”).
2. Confirm the returned checksum value.
Connection of checksum value and program number is shown below.
IC7, R37, C62,
C63, X1, C72,
R75~R81, R62,
R63
(
E
)* EEPROM Confirmation
-
1. EEP-ROM Confirmation (Execute the command “ChkTG8100XXrevYY.bat”).
XX: country code
YY: revision number
2. Confirm the returned checksum value.
3. The checksum is displayed in the last output line.
Note:
“XX”, “YY”, and “checksum” vary depending on the country version. You can find
them in the batch file, PQZZ- mentioned in
JIG and PC
(P.45).
IC5, C51, R62,
R63, Q14, C50,
R57~R61
(
F
)* BBIC Clock Adjustment
CLK
1. Input Command “rdeeprom 00 01 01”, then you can confirm the current value.
2. Adjust the frequency of CLK executing the command “setfreq xx (where xx is
the value)” so that the reading of the frequency counter is 10.368000 MHz ±
10 Hz.
IC10, C111,
C112, X1, R73,
C62, C63
Summary of Contents for KX-TG7100HGS
Page 2: ...2 KX TG7100HGS KX TG7102HGS KX TGA711FXS ...
Page 13: ...13 KX TG7100HGS KX TG7102HGS KX TGA711FXS 4 6 Signal Route ...
Page 19: ...19 KX TG7100HGS KX TG7102HGS KX TGA711FXS 7 4 For Service Hint ...
Page 20: ...20 KX TG7100HGS KX TG7102HGS KX TGA711FXS 8 Service Mode 8 1 Engineering Mode 8 1 1 Base Unit ...
Page 22: ...22 KX TG7100HGS KX TG7102HGS KX TGA711FXS 8 1 2 Handset ...
Page 28: ...28 KX TG7100HGS KX TG7102HGS KX TGA711FXS Cross Reference Check Point Base Unit P 32 ...
Page 42: ...42 KX TG7100HGS KX TG7102HGS KX TGA711FXS 10 1 2 Handset ...
Page 43: ...43 KX TG7100HGS KX TG7102HGS KX TGA711FXS 10 1 3 Charger Unit ...
Page 44: ...44 KX TG7100HGS KX TG7102HGS KX TGA711FXS 10 2 How to Replace the Handset LCD ...
Page 73: ...73 KX TG7100HGS KX TG7102HGS KX TGA711FXS 15 3 Cabinet and Electrical Parts Charger Unit ...