29
KX-TG3521BXB/KX-TG3521BXS/KX-TG3522BXB/KX-TG3522BXS/KX-TGA351BXB/KX-TGA351BXS
4.10. Circuit Operation (Charger Unit)
The voltage from the AC adaptor is supplied to the charge circuits. Main charge (180~250 mA at the Battery) of maximum 7-
hours is started soon after the handset is placed on the charger unit. Then it changes to Trickle charge to prevent from over-
charging.
The route for this is as follows: DC+pin of CN1
→
R1 ~ R5, R7 ~ R13
→
pad
→
Handset
→
CHARGE-pad
→
DC-pin
of CN1.