12.2.4.
Commands
See the table below for frequently used commands.
Note:
For the command related with BT XBT and #X, the example of this, refer to
Things to Do after Replacing IC or X'tal
(P.63)
Command name
Function
Example
XBT 0
Base unit only.
For excluding failure of command
response.
Please send this command at first
before other command is executed.
*However, if you want to execute "#X"
command
then DO NOT USE this command.
Type "sendchar XBT 0".
rdeeprom
Read the data of EEPROM
Type “rdeeprom 00 00 FF”, and the data from address
“00 00” to “FF” is read out.
readid
Read ID (RFPI)
Type “readid”, and the registered ID is read out.
writeid
Write ID (RFPI)
Type “writeid 00 18 E0 0E 98”, and the ID “0018 E0 0E
98” is written.
hookoff
Off-hook mode on Base
Type “hookoff”.
hookon
On-hook mode on Base
Type “hookon”.
getchk (Base unit)
Read checksum
Type “getchk”.
How to use of
"getchk"
in Handset
1.rdeeprom
Read EEPROM
Type “RdEeprom 03 7D 04”, and the data from address
"03 7D" to "03 80" is read out
*This command gets 4 byte "WW", "XX", "YY", "ZZ".
*Please NEVER forget these 4 byte data!
2.sendchar epw
Write EEPROM
Type “sendchar epw 03 7D 04 FF FF FF FF”
3.sendchar RST
Reset baseset
Type “sendchar RST”
4.getchk
Read checksum
Type “getchk”.
5.sendchar epw
Write EEPROM
Type “sendchar epw 03 7D 04 WW XX YY ZZ”
*"WW", "XX", "YY", "ZZ" is 4 byte data that already read
from same address.
wreeprom
Write the data of EEPROM
Type “wreeprom 01 23 45”. “01 23” is address and “45”
is data to be written.
hs_burst
Handset outputs RF power in burst test
mode
Type"hs_burst"
bs_burst
Base unit outputs RF power in burst
test mode on antenna 2
Type"bs_burst"
tx_high
Keep TX power high
Type"tx_high"
tx_low
Keep TX power low
Type"tx_low"
How to using "#X" command for base unit
XBT
Enter this command before using
following command "#X", "bs_burst",
tx_high" "tx_low" for Base Unit.
Type "sendchar XBT 1" and then "OK" is back when it
succeeds.
(caution)
Before entering this command, wait 10 seconds after
power on the base unit
#X
(Attention)
When type "sendchar #X" command, must be
the "X" must be capital
letter.
Read and Write BT parameters
[Read MAC address]
Type"sendchar #X sme" and MAC address is read out
(exp. sendchar #XXsme 0080 F08C FFD1)
[Write MAC address]
Type"sendchar #X sme **** **** ****" and
(note) part of **** should be set correct MAC address
[Read the data of crystal of BT]
Type"sendchar #X nc" and adjustment parameter of
crystal
of BT is read out
(exp. #XXnc=0x1D)
[Write the data of crystal of BT]
Type"sendchar #X nc **" and adjustment parameter of
crystal
of BT is read out
(note) part of ** should be set the adjusted value.