38
KX-TG1711MEB/KX-TG1712MEB/KX-TGA171MEB
11.4. The Setting Method of JIG (Handset)
11.4.1. Preparation
11.4.1.1. Equipment Required
• DECT tester: Rohde & Schwarz, CMD 60 is recommended.
• Frequency counter: it must be precise to be able to measure 1Hz (precision; ± 4ppm).
Hewlett Packard, 53131A is recommended.
• DC power: it must be able to output at least 1A current under 2.4V for Handset.
• Digital multi-meter (DMM): it must be able to measure voltage and current.
• Oscilloscope
11.4.1.2. JIG and PC
• Serial JIG
PQZZT1CD300E*
• PC which runs in DOS mode.
•
Batch file CD-ROM
for setting: PNZZTG1711ME
Note:
*: If you have the JIG Cable for TCD500 series
(PQZZ1CD505E), change the following values of
resistance. Then you can use it as a JIG Cable for both
TCD300 and TCD500 series. (It is an upper compatible JIG
Cable.)
11.4.2. PC Setting
11.4.2.1. Connections
Connect the DC Power or Battery to B) and BATTERY(-) (Handset).
Serial JIG to the Serial Port of PC.
Connect the Clip cable GND.
Connect the Clip cable TXD and RXD.
Note:
*: Comport names may vary depending on what your PC calls it.
Resistor
Old value (k
Ω
)
New value (k
Ω
)
R2
22
3.3
R3
22
3.3
R4
22
4.7
R7
4.7
10
GND (black)
3
To Serial Port
(com port 1*)
PC
(yellow)
4
TXD
4
RXD (red)
Handset P. C. board
GND
TXD
RXD
DC Power
or Battery
BATTERY
1
BATTERY
-
+
VBAT
2