Items
Adjustment
Point
Procedure
Check or
Replace Parts
(
F
)* Battery Monitor Check &
Adjustment (Important)
-
1.
Apply 2.3V ± 0.005V between TP3(+) and TP4(-) with DC power.
2.
Execute the command “deactmac” to stabilize the value.
3.
Then, execute the command “readbatt”. The returned value is XX.
4.
Confirm that XX is between 98 and A8.
98 < XX < A8 (Hex)
(If XX is out of range, change BBIC)
IC4, D2, L4,
L5, Q2, Q3,
R6, C26, F1,
R21, R4, C1
(
G
)
Battery Low
Confirmation (Important)
-
1.
Apply 2.40V between TP3(+) and TP4(-).
2.
Confirm that there is no Speaker sound (Battery low alarm).
3.
Apply 2.20V between TP3(+) and TP4(-).
4.
Confirm that there is Speaker sound (Battery low alarm).
IC4, F1, R21,
R4, C1, R103,
R110, D102,
Q104,
BUZZER
(
H
)* BBIC Clock Adjustment
(Important)
TP19
1.
Apply 2.6V between TP 3(+) and TP 4(-) with DC power.
2.
Execute the command “deactmac”.
3.
Execute the command “conttx”.
4.
Input Command “rdeeprom 00 01 01", then you can confirm the current value.
5.
Adjust the frequency of TP19 executing the command “setfreq 00 xx (where xx
is the value)” so that the reading of the frequency counter is 10.368000MHz
± 10Hz.
IC4, L3, C57,
IC3, X1, C16,
C204
(
I
)*
Transmitted Power
Confirmation
TP15
Remove the Antenna before starting steps from 1 to 5.
1.
Configure the DECT tester (CMD60) as follows;
<Setting>
•
•
•
•
Test mode: PP
•
•
•
•
RFPI: 0102030405
•
•
•
•
Traffic Channel: 5
•
•
•
•
Traffic Slot: 4
•
•
•
•
Mode: Loopback
2.
Execute the command “testmode”.
3.
Execute the command “regcmd60”.
4.
Initiate connection from DECT tester.
5.
Confirm that the NTP value at A201 (TP15) is 20dBm ~ 25dBm.
IC4, IC3, C54,
L3, C57,
R112, R18,
C61, C58
(
J
)*
Modulation Check and
Adjustment
TP15
Follow steps 1 to 4 of
(I)
above.
5. Confirm that the B-Field Modulation is 340kHz/div ~ 402kHz/div using data
type Fig31.
6. Adjust the B-Field Modulation if required. (Execute the command “Readmod”
and “Writemod xx”, where xx is the value.)
IC4, IC3, C54,
L3, C57,
R112, R18,
C61, C58
(
K
)*
Frequency Offset
Confirmation
-
Follow steps 1 to 4 of
(I)
above.
5. Confirm that the frequency offset is -50kHz ~ +50kHz.
IC4, IC3, C54,
L3, C57,
R112, R18,
C61, C58
(
L
)*
Sensitivity Receiver
Confirmation
-
Follow steps 1 to 4 of
(I)
above.
5. Set DECT tester power to -88dBm.
6. Confirm that the BER is < 1000ppm.
IC4, IC3, C54,
L3, C57,
R112, R18,
C61, C58
(
M
)*
Timing Confirmation
-
Follow steps 1 to 4 of
(I)
above.
5. Confirm that the Timing accuracy is < ± 2.0ppm.
IC4, IC3, C54,
L3, C57,
R112, R18,
C61, C58
(
N
)*
RSSI Level
Confirmation
-
Follow steps 1 to 4 of
(I)
above.
5. Set DECT tester power to -88dBm.
6. Execute the command “readrssi”.
7. Confirm: 25 < returned value < 43 (hex) (34 ± F (hex))
IC4, IC3, C54,
L3, C57,
R112, R18,
C61, C58
34
KX-TG1105RUS / KX-TG1105R UT / KX-TG1106R US / KX-TG1106R UT / KX-TGA110RUS / KX-TGA110RUT