1.4 Specifications
Installation Manual
27
Note
Devices connected to the Hybrid IP-PBX that exceed the system capacity will not function.
MEC Card Calculation
Calculate the MEC figure from the type and total number of items of equipment to be connected. If the MEC
figure exceeds 28, you need to install an MEC card. Note that you also need to connect an additional AC
adaptor in this case.
MEC Card Calculation
Calculation Example
The total MEC figure is 32. As this exceeds 28, you need to install an MEC card for this configuration.
AC Adaptor Selection
You must connect an additional AC adaptor in any of the following conditions:
•
A total of more than 4 APTs, DPTs (except KX-T7600 series), and DSS consoles (except KX-T7600
series) are connected.
•
More than 4 CSs are connected.
•
An MEC card is required to support a configuration with a total MEC figure exceeding 28.
Equipment Type
MEC Figure
PT
KX-T7600 series DPT/DSS console
1
Other DPT/DSS console
1
APT
1
Pre-installed 4 Super Hybrid Ports
4
Extension Card
*1
*1
Only the extension cards that can support SLTs count for the MEC figures.
SLC4
4
SLC8
8
HLC4
0
PLC4
0
PLC8
0
CS (1 unit)
0
VPS (1 port)
1
Equipment Type
MEC Figure
Pre-installed Super Hybrid Ports
4 ports
4
KX-T7600 series DPT
16 units
16
SLC4
2 cards
8
VPS
4 ports
4
Total
32
Summary of Contents for KX-TDA50
Page 5: ...Installation Manual 5 SAVE THESE INSTRUCTIONS ...
Page 122: ...2 11 Starting the Hybrid IP PBX 122 Installation Manual ...
Page 132: ...3 3 Installation of the Hybrid IP PBX PC Programming Software 132 Installation Manual ...
Page 150: ...4 1 Troubleshooting 150 Installation Manual ...
Page 151: ...Installation Manual 151 Section 5 Appendix ...
Page 154: ...5 1 Revision History 154 Installation Manual ...
Page 155: ...Installation Manual 155 Index ...
Page 158: ...Index 158 Installation Manual ...