4. Check the 3.8V supply rail at TP11. It must be 3.8V ± 0.2V.
5. Check the 2.65V supply rail at the collector of transistor T6. It
must be 2.65V ± 0.2V.
6. Switch off the 2.4V supply.
9.3. SET CLOCK FREQUENCY
1. Turn on the 2.4V supply.
2. Switch the handset on at the keypad.
3. Enter "DEACTMAC" from the PC to switch off the RF unit.
4. Enter "CONTTX 0" to start continuous RF transmission.
5. Check that the current consumption is approx. 220mA.
6. Enter "RDEEPROM 00 00 02" to display the two-byte frequency
adjustment value, MSB first.
7. Connect the frequency counter probe to TP24 to measure the
SYRI signal from the BBIC.
8. The clock frequency should be within 10,368,000Hz ± 10Hz. If not
then enter "SETFREQ nn nn" where nn nn are the clock frequency
adjustment values. An increase in the value will lower the clock
frequency and vice versa. The maximum value is 01 FF.
9. Switch off the 2.4V supply.
9.4. LOOPBACK TESTS
1. Connect the RF input cable from the CMD60 to the "0V" and
"ANT" antenna pads.
2. Switch on the 2.4V supply.
3. Switch the handset on at the keypad.
4. Enter "RDEEPROM 00 4A 01". This will return the value "25" if a
base has been registered to the handset, or "FF" if there is no
base registered.
5. If a base is not registered to the unit (i.e. "FF" returned in step 4)
then enter "SETBASE" to induce registration.
6. Set the CMD60 to MANUAL TEST mode.
37
Summary of Contents for KX-TCD715EM
Page 2: ...1 LOCATION OF CONTROLS 1 1 Base Unit 2 ...
Page 3: ...1 2 Handset 3 ...
Page 4: ...2 DISPLAYS 2 1 Icons 4 ...
Page 11: ...11 ...
Page 12: ...12 ...
Page 13: ...5 3 Answering Call 5 4 Summary of Programmable Functions 13 ...
Page 14: ...14 ...
Page 15: ...15 ...
Page 16: ...16 ...
Page 17: ...5 5 Programmable Settings 17 ...
Page 18: ...18 ...
Page 19: ...6 CIRCUIT OPERATION BASE UNIT BLOCK DIAGRAM BASEBAND SECTION AND LINE INTERFACE BASE UNIT 19 ...
Page 32: ...7 2 RF SECTION 7 2 1 BLOCK DIAGRAM RF SECTION HANDSET 32 ...
Page 39: ...10 2 HANDSET LINK 39 ...
Page 40: ...40 ...
Page 41: ...41 ...
Page 42: ...10 3 HANDSET DOES NOT LINK 10 4 BATTERY DOES NOT CHARGE 42 ...
Page 43: ...10 5 NO VOICE RECEPTION 10 6 NO VOICE TRANSMISSION 43 ...
Page 44: ...10 7 BASE UNIT DOES NOT LINK 44 ...
Page 45: ...10 8 BASE UNIT CALLER ID PROBLEMS 45 ...
Page 47: ...13 ACCESSORIES AND PACKING MATERIALS 47 ...
Page 69: ...Unit 10 ms defaults to 100ms 69 ...
Page 86: ... 3 4 5 6 7 2 1 IC402 ...
Page 87: ...N M 3 4 5 6 7 2 1 IC402 IC400 KX TCD715EM SCHEMATIC DIAGRAM BASE UNIT RF Module ...
Page 88: ...N M 3 4 5 6 7 2 1 IC402 IC400 KX TCD715EM SCHEMATIC DIAGRAM BASE UNIT RF Module ...
Page 92: ...IC402 4 5 2 1 3 ...
Page 93: ...IC400 IC402 3 4 5 2 1 KX TCD715EM SCHEMATIC DIAGRAM HANDSET RF Section ...
Page 98: ...A KX TCD715EM SCHEMATIC DIAGRAM BASE UNIT Keypad ...
Page 102: ......