8.4.
Check Point (Charger Unit)
Items
Check
Point
Procedure
Check or
Replace Parts
(
A
)
Charging Check
-
1. Connect Charge Contact 12
Ω
/2W resistor between and charge-.
2. Measure and confirm voltage across the resistor is 2.85V ± 0.2V.
D11, R11, R12
Note:
After the measuring, sock up the solder of TP.
The connection of adjustment equipment is as shown in
Adjustment Standard (Charger Unit)
(P.34).
8.5.
Adjustment Standard (Charger Unit)
When connecting the Simulator Equipments for checking, please refer to below.
8.5.1.
Flow Solder Side View
TP3
TP2
TP1
A
D11
WHITE
BLUE
PbF
TP4
PQUP11305Z
DC POWER
6V
GND (TP2)
TP3
GND (TP2)
TP1
(A)
Digital
Volt Meter
12
Ω
/2W
R12
R11
R1
R2
Note:
(
A
) is referred to
Check Point (Charger Unit)
(P.34)
34