Items
Check
Point
Procedure
Check or
Replace Parts
(
N
)
Timing Confirmation
-
Followsteps 1 to 6 of
(I)
.
7.Confirm that the Timing accuracy is < ± 2.0ppm.
IC2, IC4, R137,
R125, C153, L8,
L5, L10, L9,
C140, C141,
DA1, C142,
C143, C144, L3,
L4, R118, R119,
L12, C30, IC11,
R10, R11, C28,
C26, C147,
C151, C157,
R123, C158,
R128, R129,
C159, C160,
R131, R130,
C161, C162,
R132, C164,
C136, R134,
R117, R127,
C156, C154,
C155, R135,
R136
(
O
)*
RSSI Level
Confirmation
-
Followsteps 1 to 6 of
(I)
.
7.Execute the command "readrssi".
8. Confirm that the returned value is 0×22 ± A (hex).
IC2, IC4, R137,
R125, C153, L8,
L5, L10, L9,
C140, C141,
DA1, C142,
C143, C144, L3,
L4, R118, R119,
L12, C30, IC11,
R10, R11, C28,
C26, C147,
C151, C157,
R123, C158,
R128, R129,
C159, C160,
R131, R130,
C161, C162,
R132, C164,
C136, R134,
R117, R127,
C156, C154,
C155, R135,
R136
(
P
)
Power RAMP
Confirmation
-
Followsteps 1 to 6 of
(I)
.
7.Confirm that Power RAMP is matching.
IC2, IC4, R137,
R125, C153, L8,
L5, L10, L9,
C140, C141,
DA1, C142,
C143, C144, L3,
L4, R118, R119,
L12, C30, IC11,
R10, R11, C28,
C26, C147,
C151, C157,
R123, C158,
R128, R129,
C159, C160,
R131, R130,
C161, C162,
R132, C164,
C136, R134,
R117, R127,
C156, C154,
C155, R135,
R136
30
KX-TCD346UAS / KX-TCD346UAT / KX-TCA132UAS / KX-TCA132UAT / KX-TCA130UAS / KX-TCA130UAT
Summary of Contents for KX-TCA130UAS
Page 10: ...10 KX TCD346UAS KX TCD346UAT KX TCA132UAS KX TCA132UAT KX TCA130UAS KX TCA130UAT ...
Page 52: ...52 KX TCD346UAS KX TCD346UAT KX TCA132UAS KX TCA132UAT KX TCA130UAS KX TCA130UAT ...
Page 61: ...22 2 Handset 61 KX TCD346UAS KX TCD346UAT KX TCA132UAS KX TCA132UAT KX TCA130UAS KX TCA130UAT ...
Page 86: ...Memo 86 KX TCD346UAS KX TCD346UAT KX TCA132UAS KX TCA132UAT KX TCA130UAS KX TCA130UAT ...
Page 91: ...Memo 91 KX TCD346UAS KX TCD346UAT KX TCA132UAS KX TCA132UAT KX TCA130UAS KX TCA130UAT ...