Announce Mode
Specifies if the IP-CS’s (KX-NS0154 only) built-in ANNOUNCE feature is enabled. An IP-CS (KX-NS0154 only)
in a remote location with ANNOUNCE enabled can provide the PBX’s IP Address information to other terminals
in the remote location in place of manually programming the PBX’s IP address at each terminal.
Default
Disable
Value Range
Disable, Enable
Maintenance Console Location
9.19 PBX Configuration—[1-1] Configuration—Slot—V-IPCS4—Port Property
Secondary Setting
The settings on this screen are for programming the Automatic Rerouting to Secondary PBX feature for use
among IP-CSs (KX-NS0154 only) in a networked environment. For details and conditions regarding the use
of this feature, refer to
2.1.7 Automatic Rerouting to Secondary PBX
in the Feature Manual.
Setting Secondary Ports
Follow the steps below to designate secondary ports for IP-CSs.
1.
Specify the secondary ports.
a.
Access the port property screen of the site where the ports will be set as secondary ports.
b.
In
, set the unused ports that will be used as secondary ports to "Secondary".
Note
Ports that have already been registered (A value other than the default of "00:00:00:00:00:00" is
set for
MAC Address
on the
Main
tab) cannot be set to "Secondary" here.
2.
Access the port property screen of the site where primary ports will be assigned secondary ports.
3.
Click
Set Secondary
. A dialog box will appear.
4.
From the drop-down list, select a site where secondary ports will be assigned.
Note
The number displayed for
Available ports
indicates the maximum number of available ports at the
selected site that can be registered as secondary ports.
5.
IP-CSs’ primary ports and names are displayed on the left. Select the IP-CSs for which to want to register
secondary ports, and then click the right arrow.
Note
Ports that are already assigned as secondary ports will not be displayed in this list.
6.
Click
Execute
. A message confirming the registration will be displayed.
7.
for each site where you want to designate secondary ports.
Removing Secondary Port Settings
Follow the steps below to remove secondary port settings for IP-CSs.
1.
Click
Remove Secondary
. A dialog box will appear.
2.
Primary ports of IP-CSs that have secondary ports assigned are displayed on the left. Select the IP-CSs
whose secondary setting you want to remove, and then click the right arrow.
3.
Click
Execute
. A message confirming the setting removal will be displayed.
400
PC Programming Manual
Document Version 2016-03
9.19 PBX Configuration—[1-1] Configuration—Slot—V-IPCS4—Port Property
Summary of Contents for KX-NS1000
Page 32: ...32 PC Programming Manual Document Version 2016 03 1 2 3 PBX Configuration Types ...
Page 60: ...60 PC Programming Manual Document Version 2016 03 2 3 Frequently Asked Questions FAQ ...
Page 68: ...68 PC Programming Manual Document Version 2016 03 3 1 1 Home Screen Add Site Wizard ...
Page 112: ...112 PC Programming Manual Document Version 2016 03 6 14 Tool URL Information ...
Page 170: ...170 PC Programming Manual Document Version 2016 03 7 13 Utility Flash ROM ID Information ...
Page 844: ...844 PC Programming Manual Document Version 2016 03 14 6 PBX Configuration 6 6 Feature Tenant ...
Page 996: ...996 PC Programming Manual Document Version 2016 03 21 1 UM Configuration 2 Class of Service ...
Page 1082: ...1082 PC Programming Manual Document Version 2016 03 25 1 UM Configuration 6 H W Settings ...
Page 1232: ...1232 PC Programming Manual Document Version 2016 03 28 4 2 Network Service 4 2 Other NAS ...
Page 1233: ...Section 29 Appendix Document Version 2016 03 PC Programming Manual 1233 ...
Page 1241: ...Feature Programming References Document Version 2016 03 PC Programming Manual 1241 ...