4   Deployment Procedure

4.1  Overview

4.2  Site Planning

4.3  Site Survey

4.4  Example of How to Conduct the Site Survey

4.5  Example of How to Make a Site Map

4.6  Basic Network Configuration

4.7  CS Registration

4.8  Configuration and PS Registration (for a system
using a KX-NS series)

16

Quick Installation Guide

4 Deployment Procedure

Summary of Contents for KX-NS0154

Page 1: ...duct and save this manual for future use Notes In this manual the suffix of each model number e g KX NS0154CE is omitted unless necessary The screen shots shown in this guide are provided for reference only and may differ from the screens displayed on your PC The contents and design of the software are subject to change without notice KX NS0154 Software File Version 01 000 or later ...

Page 2: ... the IP CS 15 4 Deployment Procedure 16 4 1 Overview 16 4 2 Site Planning 16 4 3 Site Survey 16 4 4 Example of How to Conduct the Site Survey 16 4 5 Example of How to Make a Site Map 16 4 6 Basic Network Configuration 16 4 7 CS Registration 16 4 8 Configuration and PS Registration for a system using a KX NS series 16 5 Troubleshooting 17 6 Appendix 18 6 1 Specifications 18 2 Quick Installation Gui...

Page 3: ...ing For more information about collection and recycling of old products and batteries please contact your local municipality your waste disposal service or the point of sale where you purchased the items Penalties may be applicable for incorrect disposal of this waste in accordance with national legislation For business users in the European Union If you wish to discard electrical and electronic e...

Page 4: ...ions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Some wireless telephones operate at frequencies that may cause interference to nearby TVs and VCRs To minimize or prevent such interference the base of the wireless telephone should not be placed near or on top of a TV or VCR If int...

Page 5: ...ll often reduce or eliminate interference Notes The screen shots shown in this guide are provided for reference only and may differ from the screens displayed on your PC The contents and design of the software are subject to change without notice Quick Installation Guide 5 1 Regional Information ...

Page 6: ...tion Handset Secondary IP CS Secondary IP CS for air synchronization Super Master IP CS Master IP CS of Air Sync Group 1 This IP CS manages configuration for the whole system Web Maintenance Console Used for system programming diagnosis and administration of the KX NS series PBX via PCs Web Maintenance Console is accessed through a Web browser running on a networked PC System Overview This IP CS c...

Page 7: ...ement System You can download the activation keys as an activation key file from the Key Management System To download the activation keys enter the MPR ID number shown on the back of the main unit and activation key number and registration ID provided on each activation key code For information about the type of activation key codes available refer to Activation Keys Quick Installation Guide 7 2 ...

Page 8: ...ms below IP CS 1 Wall Mounting Plate 1 Screws 2 Washers 2 LED Indications IP CS status indication Color Status Green Blue 1 ON Stand by no active calls Slow Flashing Talk active calls Moderate Flashing Busy 2 Red ON Fault Slow Flashing Out of Service Starting up data link establishment air synchronization Moderate Flashing power on data link establishment 8 Quick Installation Guide 3 Installing th...

Page 9: ...ng the IP CS Color Status Red Moderate Flashing Moderate Red Flashing The IP CS is restarting Note LED flashing patterns are as follows Slow Flashing 60 times per minute Moderate Flashing 120 times per minute Activation Keys The IP CS supports the following activation keys to expand the maximum number of calls from 4ch to 8ch Model No Activation Key Type Description KX NSE201 1 IP CS to 8 ch Allow...

Page 10: ...uld be a 10BASE T 100BASE TX CAT 5 Category 5 or higher cable and the diameter of the cable must be 6 5 mm or less It is possible to connect the unit to the LAN while registering the unit to the PBX 1 Connect the cable to the unit Ethernet Cable 2 Pass the cable through the groove of the unit in one of the following three ways To a Switching Hub To a Switching Hub 1 2 3 1 To a Switching Hub 3 Conn...

Page 11: ...ng or testing a unit with an external AC adaptor the AC adaptor should be plugged into a wall outlet or floor mounted AC outlet Do not connect the AC adaptor to a ceiling mounted AC outlet as the weight of the adaptor may cause it to become disconnected Note Use only the optional AC adaptor KX A239 for the unit 1 Connect the AC adaptor cord to the unit AC Adaptor Cord 2 Pass the cord through the g...

Page 12: ...ed to the unit with the AC power cords of machines located nearby Make sure the cables are securely fastened to the wall Notice Panasonic assumes no responsibility for injuries or property damage resulting from failures arising out of improper installation or operation inconsistent with this documentation 1 Place the reference for wall mounting on the wall to mark the 2 screw positions 2 Install t...

Page 13: ...a screw here Install a screw here 83 mm Note Make sure to set the print size to correspond with the size of this page If the dimension of the paper output still deviates slightly from the measurement indicated here use the measurement indicated here Quick Installation Guide 13 3 Installing the IP CSs ...

Page 14: ...he Maintenance Console Note Make sure to install and use the latest version of the KX TDA KX TDE KX NCP Unified Maintenance Console To install or uninstall the software on a PC running Windows XP Professional you must be logged in as a user in either the Administrators or Power Users group To install or uninstall the software on a PC running Windows Vista Business or Windows 7 Professional you mus...

Page 15: ...izing the IP CS calls cannot be made or received and ongoing conversations will be disconnected 1 Switch the Initialized Mode switch from OFF to ON 1 2 3 4 5 6 7 8 OFF ON DIP Switch Initialised Mode Switch 2 Supply electricity to the IP CS using an AC adaptor PoE hub or PoE adaptor turn on the IP CS 3 While the LED indicator flashes red Moderate Flashing 120 times per minute switch the Initialized...

Page 16: ...Survey 4 4 Example of How to Conduct the Site Survey 4 5 Example of How to Make a Site Map 4 6 Basic Network Configuration 4 7 CS Registration 4 8 Configuration and PS Registration for a system using a KX NS series 16 Quick Installation Guide 4 Deployment Procedure ...

Page 17: ...5 Troubleshooting Quick Installation Guide 17 5 Troubleshooting ...

Page 18: ...V206 VoIP Audio Codec G 711 G 729A G 726 LAN Port 10 BASE T 100 BASE TX VLAN Yes 802 1Q IP Addressing DHCP Static IP Address Setting Software Upgrade Yes Built in VPN No Weight 330 g Size W 190 mm H 133 9 mm D 39 3 mm 1 The activation keys are required to expand the maximum number of calls from 4ch to 8ch For more details refer to Activation Keys RF Specification Item Description Radio Access Meth...

Page 19: ...0 C and vibration and should not be exposed to direct sunlight The IP CS should not be placed outdoors use indoors The IP CS should not be placed near high voltage equipment The IP CS should not be placed on a metal object Compatible PSs Model No KX TCA185 KX TCA285 KX TCA385 KX WT125 KX WT126 KX TD7685 KX TD7695 KX TD7969 Quick Installation Guide 19 6 Appendix ...

Page 20: ... www ptc panasonic eu Contact to Authorized Representative Panasonic Testing Center Panasonic Marketing Europe GmbH Winsbergring 15 22525 Hamburg Germany 1 62 4 chome Minoshima Hakata ku Fukuoka 812 8531 Japan Web Site http www panasonic net Copyright This material is copyrighted by Panasonic System Networks Co Ltd and may be reproduced for internal use only All other reproduction in whole or in p...