Code
Function
Set Value
Default
Remote setting
591
FAX auto redial line disconnection time set
001~999
065
OK
592
CNG transmit select
1:OFF/2:ALL/3:AUTO
ALL
OK
593
Time between CED and 300 bps
1:75/2:500/3:1s
75 ms
OK
594
Overseas DIS detection select
1:1st/2:2nd
1st
OK
595
Receive error limit value set
001~999
100
OK
596
Transmit level set
15~00
10
OK
598
Receiving Sensitivity
20~48
42
OK
710
Memory clear except History data
---------
---------
NG
717
Transmit speed select
1:9600/2:7200/3:4800/4:2400bps
9600bps
OK
718
Receive speed select
1:9600/2:7200/3:4800/4:2400bps
9600bps
OK
719
Ringer off in TEL/FAX mode
1:ON/2:OFF
ON
OK
721
Pause tone detect
1:ON/2:OFF
ON
OK
722
Redial tone detect
1:ON/2:OFF
ON
OK
731
CPC mode
1:A / 2:B / 3:OFF
A
OK
763
Friendly reception CNG detection select
1:10S/2:20S/3:30S
20S
OK
771
T1 timer
1:35 sec/2:60 sec
35 sec
OK
774
T4 timer
00~99 X 100ms
00
OK
775
Monitoring of message transfer
1:ON/2:OFF
OFF
OK
815
Sensor check
Press "START".
---------
NG
841
Digital SP-Phone RX & TX check
1: SP-Phone
---------
NG
882
Journal 3
1: START
---------
NG
991
Transmit basic list
1: START
---------
OK
992
Transmit advanced list
1: START
---------
OK
994
Transmit journal report
1: START
---------
OK
999
Transmit service list
1: START
---------
OK
OK : Can set the value by the remote programming feature or print a list.
NG : Cannot set the value.
Note:
Note: Refer to SERVICE FUNCTION TABLE (P.43) for descriptions of the individual codes.
For example, the "004 Transmission report mode" set value "1:ERROR/2:ON/3:OFF" number corresponds to the number
dialled.
49
KX-FT907BX-B / KX-FT907BX-W
Summary of Contents for KX-FT907BX-B
Page 25: ...6 DISASSEMBLY INSTRUCTIONS 6 1 HOW TO REMOVE PAPER STACKER 25 KX FT907BX B KX FT907BX W ...
Page 26: ...6 2 HOW TO REMOVE THE OPERATION PANEL BLOCK 26 KX FT907BX B KX FT907BX W ...
Page 27: ...6 3 HOW TO REMOVE THE OPERATION BOARD AND LCD 27 KX FT907BX B KX FT907BX W ...
Page 28: ...6 4 HOW TO REMOVE THE IMAGE SENSOR 28 KX FT907BX B KX FT907BX W ...
Page 29: ...6 5 HOW TO REMOVE THE THERMAL HEAD AND CUTTER UNIT 29 KX FT907BX B KX FT907BX W ...
Page 30: ...6 6 HOW TO REMOVE THE DOCUMENT TRAY 30 KX FT907BX B KX FT907BX W ...
Page 31: ...6 7 HOW TO REMOVE THE BOTTOM FRAME 31 KX FT907BX B KX FT907BX W ...
Page 32: ...6 8 HOW TO REMOVE THE HANDSET CRADLE CABINET AND SPEAKER 32 KX FT907BX B KX FT907BX W ...
Page 34: ...6 10 HOW TO REMOVE THE ROLLERS 34 KX FT907BX B KX FT907BX W ...
Page 35: ...6 11 HOW TO REMOVE THE MOTOR BLOCK 35 KX FT907BX B KX FT907BX W ...
Page 37: ...37 KX FT907BX B KX FT907BX W ...
Page 38: ...6 12 INSTALLATION POSITION OF THE LEAD WIRES 38 KX FT907BX B KX FT907BX W ...
Page 39: ...6 13 INSTALLATION OF THERMAL HEAD 39 KX FT907BX B KX FT907BX W ...
Page 51: ...7 4 6 SERVICE MODE SETTINGS Example of a printed out list 51 KX FT907BX B KX FT907BX W ...
Page 57: ...7 5 4 4 SKEW CROSS REFERENCE DISASSEMBLY INSTRUCTIONS P 25 57 KX FT907BX B KX FT907BX W ...
Page 63: ...7 5 5 1 2 SOMETIMES THERE IS A TRANSMIT PROBLEM 63 KX FT907BX B KX FT907BX W ...
Page 65: ...7 5 5 1 4 THE UNIT CAN COPY BUT CANNOT TRANSMIT RECEIVE 65 KX FT907BX B KX FT907BX W ...
Page 72: ...Countermeasure 72 KX FT907BX B KX FT907BX W ...
Page 73: ...73 KX FT907BX B KX FT907BX W ...
Page 74: ...74 KX FT907BX B KX FT907BX W ...
Page 75: ...75 KX FT907BX B KX FT907BX W ...
Page 76: ...76 KX FT907BX B KX FT907BX W ...
Page 77: ...77 KX FT907BX B KX FT907BX W ...
Page 78: ...78 KX FT907BX B KX FT907BX W ...
Page 79: ...79 KX FT907BX B KX FT907BX W ...
Page 84: ...84 KX FT907BX B KX FT907BX W ...
Page 87: ...87 KX FT907BX B KX FT907BX W ...
Page 90: ...7 5 8 3 NG EXAMPLE 90 KX FT907BX B KX FT907BX W ...
Page 92: ...92 KX FT907BX B KX FT907BX W ...
Page 94: ...Note Inside the digital board Inside the operation board 94 KX FT907BX B KX FT907BX W ...
Page 95: ...7 5 9 2 DEFECTIVE ITS INTEGRATED TELEPHONE SYSTEM SECTION 95 KX FT907BX B KX FT907BX W ...
Page 97: ...2 Troubleshooting Flow Chart 97 KX FT907BX B KX FT907BX W ...
Page 101: ...CROSS REFERENCE TEST FUNCTIONS P 45 101 KX FT907BX B KX FT907BX W ...
Page 103: ...8 CIRCUIT OPERATIONS 8 1 CONNECTION DIAGRAM 103 KX FT907BX B KX FT907BX W ...
Page 105: ...8 2 1 GENERAL BLOCK DIAGRAM 105 KX FT907BX B KX FT907BX W ...
Page 114: ...8 4 2 BLOCK DIAGRAM 114 KX FT907BX B KX FT907BX W ...
Page 116: ...116 KX FT907BX B KX FT907BX W ...
Page 122: ...8 4 6 3 4 COPYING CROSS REFERENCE SENSOR SECTION P 100 122 KX FT907BX B KX FT907BX W ...
Page 138: ...8 10 2 CIRCUIT DIAGRAM 138 KX FT907BX B KX FT907BX W ...
Page 148: ...Refer to ANALOG BOARD SECTION P 93 148 KX FT907BX B KX FT907BX W ...
Page 149: ...9 3 TEST CHART 9 3 1 ITU T No 1 TEST CHART 149 KX FT907BX B KX FT907BX W ...
Page 150: ...9 3 2 ITU T No 2 TEST CHART 150 KX FT907BX B KX FT907BX W ...
Page 151: ...10 FIXTURES AND TOOLS 151 KX FT907BX B KX FT907BX W ...
Page 152: ...11 CABINET MECHANICAL 11 1 OPERATION PANEL SECTION 152 KX FT907BX B KX FT907BX W ...
Page 153: ...11 2 UPPER CABINET SECTION 153 KX FT907BX B KX FT907BX W ...
Page 154: ...11 3 LOWER CABINET CROSS REFERENCE MOTOR SECTION P 155 154 KX FT907BX B KX FT907BX W ...
Page 155: ...11 4 MOTOR SECTION 155 KX FT907BX B KX FT907BX W ...
Page 156: ...11 5 ACTUAL SIZE OF SCREWS 156 KX FT907BX B KX FT907BX W ...
Page 157: ...12 ACCESSORIES AND PACKING MATERIALS 157 KX FT907BX B KX FT907BX W ...
Page 173: ...16 MEMO 173 KX FT907BX B KX FT907BX W ...
Page 180: ...180 KX FT907BX B KX FT907BX W Y M KXFT907BXB KXFT907BXW ...