Items
Adjustment
Point
Procedure*
Check
(K)
Sensitivity
Receiver
Confirmation
-
Follow steps 1 to 3 of (H) above.
4. Set DECT tester power to -88dBm.
5. Confirm that the BER is < 1000ppm.
IC2,IC3,L1,
C75,C69,C48,
C67,C76,C57,
DA1,R66,R67,
R78,R79,C54,
(L)
Timing
Confirmation
-
Follow steps 1 to 3 of (H) above.
4. Confirm that the Timing accuracy is < ± 2.0ppm.
IC2,IC3,L1,
C75,C69,C48,
C67,C76,C57,
DA1,R66,R67,
R78,R79,C54,