Address
Default
Name
Country
Setting
Type
Description
0F66
08
DetData
18
D
Detection data
Bit
0: Selection CPC A/B 0:OFF (A fixed)/
ON(Select)
1: Reserve
2: Detect 1st Short Bell (300ms) for count
3: Cyclic Detection of VOX 0: OFF/1:
ON(Detect)
4: Detection of DSC 0: OFF/1: ON(Detect)
5: Reserve
6: Reserve
7: Reserve
0F67
06
OptionData
25
D
Each country data
Bit
0: 2 Way Beep ON/OFF 0:OFF/1:ON
1: 2 Way Beep interval 0:15s per 400ms
:20s per 160ms
2: 2 Way Rec ON/OFF 0:OFF/1:ON
3: Switching of VOX Sense ON/OFF 0
OFF/1:ON
4: Key Click Tone ON/OFF Not used
5: Select Compression Rate Menu 0:Not
Active/ 1:Active
6: 2 Way Beep interval2
*For UK (15s per 400ms 1khz)
2 wayBeepInterval=0 2wayBeepInterval2
=0
*For FR (20s per 160ms 1khz)
2wayBeepInterval=1 2wayBaeepInterval2
=0
*For AL (15s per 420ms 1.4khz)
2wayBeepInterval=1 2wayBeepInterval2
1
7: Reserve
0F68
00
TamPrgWordMode
x
D
Language select data
For Switzerland 0:Germany/1:French
For Czech 0:Chezh/1:Slovakian
0F69
27
TamRingsSetNum
x
D
Number of rings select range for
automatic answering
0x25: 2 ~ 5 Rings
0x27: 2 ~ 7 Rings
74
www.freeservicemanuals.info
1/2/2015
Digitized in Heiloo, Holland