4.5.
SCSI Setting (Only for KV-S2025C/S2045C Series)
Set SCSI ID and Terminator on the DIP Switch whose layout is shown on Fig. 4.5.1.
Fig. 4.5.1
4.5.1.
SCSI ID
Referring to the following Fig. 4.5.2, be sure to set a scanner´s SCSI ID number of the DIP Switch, different from the other SCSI
device in the SCSI chain.
Fig. 4.5.2
SCSI ID
Number
DIP Switch Setting
Remarks
ID2
ID1
ID0
0
OFF
OFF
OFF
1
OFF
OFF
ON
2
OFF
ON
OFF
3
OFF
ON
ON
4
ON
OFF
OFF
5
ON
OFF
ON
6
ON
ON
OFF
KME Factory Default
7
ON
ON
ON
Note
It is not until restarting the PC after restarting the scanner that Setting "SCSI ID" will be activated.
4.5.2.
Terminator
According to the SCSI interface condition, set the Terminator (TERM) ON or OFF.
Note
1.
If the scanner is the last or the only device in the SCSI chain, the terminator should be set to "ON".
2.
It is not until restarting the PC after restarting the scanner that Setting "Terminator ON or OFF" will be activated.
10
KV-S2025C Series / KV-SU225C Series / KV-S2045C Series / KV-SU245C Series
Summary of Contents for KV-S2045C
Page 96: ...96 KV S2025C Series KV SU225C Series KV S2045C Series KV SU245C Series ...
Page 114: ...KV S2025C Series KV SU225C Series KV S2045C Series KV SU245C Series 114 ...
Page 116: ...14 1 Exterior 116 KV S2025C Series KV SU225C Series KV S2045C Series KV SU245C Series ...
Page 118: ...14 2 Chassis and Base 118 KV S2025C Series KV SU225C Series KV S2045C Series KV SU245C Series ...
Page 120: ...14 3 Hopper Unit 120 KV S2025C Series KV SU225C Series KV S2045C Series KV SU245C Series ...
Page 122: ...14 4 Power Unit 122 KV S2025C Series KV SU225C Series KV S2045C Series KV SU245C Series ...