Troubleshooting III  

  

 

  

 

  

 

  

Symptom 

  

Possible Cause 

  

Remedy 

  

The image for a scanned 

document is blank. 

  

The document to be scanned was 

loaded upside down. 

  

Load the document correctly. 

  

Vertical streaks appear on the 

scanned document.  

  

The scanning glasses are dirty.  

  

Clean the scanning glasses. 

  

The scanning density is uneven. 

  

The scanning glasses are dirty.  

  

Clean the scanning glasses. 

  

The color of the scanned 

document is extremely different 

from the original document. 

  

The settings of the computer 

monitor are wrong. 

  

Adjust the computer monitor 

settings. 

  

Depending on the documents 

scanned, the color of documents 

  

may not be scanned properly. For 

 

example, the color of a highlighter 

pen may be scanned lighter than it 

appears. 

  

Setting the value for Chroma 

higher in the scanning conditions 

may solve this problem. 

  

Dark spots or noise appear on the 

scanned documents. 

  

The scanning glasses are dirty.  

  

Clean the scanning glasses. 

  

There is noise or wave patterns 

  

(moire pattern) on the scanned 

image. 

  

The scanning resolution settings, 

combined with patterns within the 

scanned image, may cause this 

problem. 

  

Change the scanning resolution, 

and perform scanning again. 

  

The sound made by paper being 

ejected is higher than usual when 

you scan short documents. 

  

If the length of documents are less 

than about 148 mm (5.8 in.), 

  

feeding speed control will be 

  

activated for exiting documents; 

this is normal behavior. 

  

— 

  

 