32
OFF
ON
SV setting
OFF
ON
8
8
8
7
7
7
7
+
8
-
12V DC
7
+
8
-
0/12V DC
7
+
8
-
0V DC
7
+
8
-
20mA DC
7
+
8
-
4 to 20mA DC
7
+
8
-
4mA DC
5
5
5
6
6
6
5
+
6
-
12V DC
5
+
6
-
0V DC
5
+
6
-
12/0V DC
Indicator
(OUT1)
(OUT2)
(OUT1)
Cooling P-band
Non-contact
voltage output
Control action
Heating
action
Relay contact
output (OUT1)
DC current
output (OUT1)
Relay contact
output (OUT2)
Non-contact
voltage output
Indicator
(OUT2)
Heating P-band
(Cooling
action)
Cycle action is performed according to deviation.
Cycle action is performed according to deviation.
Changes continuously according to deviation.
Cycle action is performed according to deviation.
Cycle action is performed according to deviation.
Lit
Unlit
Lit
Unlit
11.7 OUT2 (Heating/Cooling control) action [Reverse (Heating) action] (When setting overlap band)
Heating/Cooling control can be used
by adding Heating/Cooling control
option.
Heating proportional band can be set
during [6] OUT1 proportional band setting,
and cooling proportional band can be set
during [7] OUT2 proportional band setting
in the Sub setting mode. (p.14)
Overlap band can be set during
[36] Overlap band/Dead band setting
in the Setup mode.(p.19)
[48] Direct/Reverse control can be set
in the Setup mode. (p.21)
: Acts ON (lit) or OFF (unlit).
: Represents Heating control
action.
: Represents Cooling control
action.
11.8 OUT2 (Heating/Cooling control) action [Direct (Cooling) action]
Heating/Cooling control can be used
by adding Heating/Cooling control
option.
Heating proportional band can be set
during [6] OUT1 proportional band
setting, and cooling proportional band
can be set during [7] OUT2 proportional
band setting in the Sub setting mode.
(p.14)
[48] Direct/Reverse control can be set
in the Setup mode. (p.21)
: Acts ON (lit) or OFF (unlit).
: Represents Heating control
action.
: Represents Cooling control
action.
OFF
ON
OFF
ON
8
8
8
7
7
7
5
5
5
6
6
6
Indicator
(OUT1)
(OUT2)
5
5
5
6
6
6
(OUT1)
8
8
8
7
7
7
8
8
8
7
7
7
12V DC
12/0V DC
0V DC
20mA DC
20 to 4mA DC
4mA DC
0V DC
12/0V DC
12V DC
Heating P-band
Cooling P-band
Non-contact
voltage output
Control action
SV setting
Heating
action
(Cooling
action)
Relay contact
output (OUT1)
Lit
Lit
Unlit
Unlit
DC current
output (OUT1)
Relay contact
output (OUT2)
Non-contact
voltage output
Indicator
(OUT2)
Cycle action is performed according to deviation.
Cycle action is performed according to deviation.
Changes continuously according to deviation.
Cycle action is performed according to deviation.
Cycle action is performed according to deviation.
Overlap
band