Heating P-band
Dead band
(Cooling P-band)
Control action
(Cooling
action)
Heatng
action
Cycle action is performed according to deviation.
Relay contact
output (OUT1)
Non-contact
voltage output
(OUT1)
Changes continuously according to deviation.
DC current
output (OUT1)
Unlit
Indicator
(OUT1)
Lit
OFF
ON
SV setting
OFF
ON
7
+
8
-
12V DC
7
+
8
-
12/0V DC
7
+
8
-
0V DC
7
+
8
-
20mA DC
7
+
8
-
20 to 4mA DC
7
+
8
-
4mA DC
8
8
8
7
7
7
6
6
6
5
5
5
(OUT2)
5
+
6
-
12V DC
5
+
6
-
12/0V DC
5
+
6
-
0V DC
Indicator
(OUT2)
Cycle action is performed according to deviation.
Cycle action is performed according to deviation.
Cycle action is performed according to deviation.
Lit
Unlit
Non-contact
voltage output
Relay contact
output (OUT2)
11.5 OUT2 (Heating/Cooling control) action [Reverse (Heating) action]
Heating/Cooling control can be used
by adding Heating/Cooling control
option.
Heating proportional band can be
set during [6] OUT1 proportional band
setting, and cooling proportional band
can be set during [7] OUT2 proportional
band setting in the Sub setting mode.
(p.14)
[48] Direct/Reverse control can be
set in the Setup mode. (p.21)
: Acts ON (lit) or OFF (unlit).
: Represents Heating control
action.
: Represents Cooling control
action.
11.6 OUT2 (Heating/Cooling control) action [Reverse (Heating) action] (When setting dead band)
Heating/Cooling control can
be used by adding Heating/
Cooling control option.
Heating proportional band can
be set during [6] OUT1
proportional band setting, and
cooling proportional band
can be set during [7] OUT2
proportional band setting in the
Sub setting mode. (p.14)
Dead band can be set during
[36] Overlap band/Dead band
setting in the Setup mode.(p.19)
[48] Direct/Reverse control can
be set in the Setup mode. (p.21)
: Acts ON (lit) or OFF
(unlit).
: Represents Heating
control action.
: Represents Cooling
control action.
Control
action
Heating P-band
(Cooling P-band)
Heating
action
(Cooling
action)
Relay contact
output (OUT2)
Non-contact
voltage output
(OUT1)
Changes continuously according to deviation.
DC current
output (OUT1)
20 to
Cycle action is performed according to deviation.
OFF
ON
SV setting
OFF
ON
8
8
8
7
7
7
(OUT1)
7
+
8
-
12V DC
7
+
8
-
12/0V DC
7
+
8
-
0V DC
7
+
8
-
20mA DC
7
+
8
-
4mA DC
7
+
8
-
4mA DC
5
+
6
-
12V DC
5
+
6
-
0V DC
5
+
6
-
12/0V DC
Non-contact
voltage output
(OUT2)
Relay contact
output (OUT1)
Indicator
(OUT2)
Indicator
Unlit
Lit
Unlit
Lit
Cycle action is performed according to deviation.
Cycle action is performed according to deviation.
5
5
5
6
6
6
Cycle action is performed according to deviation.