7.4.5 Utility—Monitor/Trace—UM System Trace (Internal)
Unified Messaging (UM) system processes can be monitored and logged.
This screen can be accessed only in On-line mode.
The following data can be traced and logged for each UM port, or all UM ports:
•
DTMF / Dial: data regarding DTMF signals received by the Unified Messaging system.
•
Guidance: guidance data that the Unified Messaging system played.
•
Message: Unified Messaging system activity for messages such as creating, playing and deleting.
•
Process Event: events occurred between Unified Messaging system processes such as Application, Call
Processor and DSP.
•
Caller ID: received Caller ID information.
•
DID: received DID numbers.
•
PIN: PINs received by the Unified Messaging system.
Follow the steps below to monitor or log the system trace data.
1.
Select
Internal Trace
,
Display
, or
Trace Clear
.
–
Setting
1.
Check
Enable / Disable Trace Data
.
2.
Check the data and UM ports you wish to monitor.
3.
Click
OK
.
–
Display
: Displays the trace data and/or error data.
1.
Check the data and UM ports you wish to monitor.
2.
To include error data, click the
Error Trace
tab and check
Error Data
.
3.
Click
OK
.
4.
The selected data will be displayed in a new window. Click the
Trace Data
or
Error Trace
tabs to
switch views. Click
Save Log File
to save a copy of the displayed data.
5.
Click
Cancel
when finished.
–
Trace Clear
: Clears saved trace data.
1.
Select the trace data to clear.
2.
Click
OK
to clear the selected trace data.
3.
The message "System Trace Clear Successful" will be displayed. Click
OK
to continue.
118
PC Programming Manual
7.4.5 Utility—Monitor/Trace—UM System Trace (Internal)
Summary of Contents for KMS1409096CE
Page 21: ...21 KX NS500AG 5 Location of Controls and Components 5 1 Name and Locations ...
Page 24: ...24 KX NS500AG 9 1 1 Startup ...
Page 25: ...25 KX NS500AG ...
Page 26: ...26 KX NS500AG ...
Page 27: ...27 KX NS500AG ...
Page 28: ...28 KX NS500AG 9 1 2 Battery Alarm ...
Page 29: ...29 KX NS500AG 9 1 3 Using Voice Mail ...
Page 30: ...30 KX NS500AG Using Voice Mail continued ...
Page 34: ...34 KX NS500AG 9 2 3 41V are Not Output Only 15V is output ...
Page 35: ...35 KX NS500AG 9 2 4 Battery Backup Function Does Not Operate PSU can Not Charge Batteries ...
Page 43: ...43 KX NS500AG 11 3 3 Power Supply Board ...
Page 59: ...59 KX NS500AG 12 2 Memo ...
Page 73: ...73 KX NS500AG 12 5 Memo ...
Page 131: ...131 KX NS500AG 16 Appendix ...