Panasonic K3 Operating Instructions Manual Download Page 12

12

Connectable outdoor unit lineup

Europe

 

„

Refrigerant type : R32

Outdoor unit type

36

50

60

PZH2

1-phase

U-36PZH2E5

U-50PZH2E5

U-60PZH2E5

3-phase

PZ2

1-phase

U-60PZ2E5

3-phase

Outdoor unit type

71

100

125

140

PZH2

1-phase

U-71PZH2E5

U-100PZH2E5

U-125PZH2E5

U-140PZH2E5

3-phase

U-71PZH2E8

U-100PZH2E8

U-125PZH2E8

U-140PZH2E8

PZ2

1-phase

U-71PZ2E5

U-100PZ2E5

U-125PZ2E5

U-140PZ2E5

3-phase

U-100PZ2E8

U-125PZ2E8

U-140PZ2E8

Outdoor unit type

36

50

60

PZH3

1-phase

U-36PZH3E5

U-50PZH3E5

U-60PZH3E5

3-phase

PZ3

1-phase

U-36PZ3E5

U-50PZ3E5

U-60PZ3E5

3-phase

Outdoor unit type

71

100

125

140

PZH3

1-phase

U-71PZH3E5

U-100PZH3E5

U-125PZH3E5

U-140PZH3E5

3-phase

U-71PZH3E8

U-100PZH3E8

U-125PZH3E8

U-140PZH3E8

PZ3

1-phase

U-71PZ3E5

U-100PZ3E5

U-125PZ3E5

U-140PZ3E5

3-phase

U-100PZ3E8

U-125PZ3E8

U-140PZ3E8

Operation Mechanism

 

„

Heating performance

z

z

This air conditioner utilizes outside air for heating; its 

heating performance reduces as outside temperature 

decreases. 

→ In the event that heating is not sufficient, please use an 

additional heating appliance.

 

„

Defrosting

z

z

This appliance may start defrosting operation to melt 

frost formed in the outdoor unit.

 

Defrosting starts

: The indoor unit fan stops (or the 

speed becomes extremely slow). 

→ “ ” (STANDBY) appears.

 

Heating operation resumes after several 

minutes

: The indoor unit fan remains stopped (or 

it will run at a very slow speed) until the indoor heat 

exchanger coil warms up sufficiently.

 

→ “ ” (STANDBY) appears.

 

Defrosting is complete

: The indoor unit fan starts 

operation. 

→ “ ” (STANDBY) disappears.

 

„

‘‘DRY’’ operation

z

z

Once the room temperature reaches the level that was 

set, the outdoor unit repeats the cycle of turning on and 

off automatically.

z

z

When the room temperature is more likely to reach the 

level that was set, the fan speed is set to ‘‘breeze’’ (light 

wind) automatically.

 

„

Should power failure occur while the unit is 

running

The unit will resume operation automatically. Operation 

settings prior to power failure will be used.

OI_00_321038_EN.indb   12

2020/10/27   10:53:20

Summary of Contents for K3

Page 1: ...ructions thoroughly and keep them for future reference Panasonic Corporation 1006 Kadoma Kadoma City Osaka Japan WEB ACXF55 28650 EN Wall Mounted Type K3 Model No INDOOR UNIT Wall Mounted Type K3 S 36...

Page 2: ...comfortable room conditions Use this only for its intended purpose as described in these Operating Instructions Confirm to authorized dealer or specialist on usage of specified refrigerant type Using...

Page 3: ...s must be incorporated in the fixed wiring in accordance with the wiring rules To prevent possible hazards from insulation failure the unit must be grounded WARNING Do not use modified cord joint cord...

Page 4: ...or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children...

Page 5: ...recovery and recycling of old products and used batteries please take them to applicable collection points in accordance with your national legislation and the Directives 2002 96 EC and 2006 66 EC By...

Page 6: ...rating Instructions attached to the Remote Controller The flap display on the remote controller differs from the actual flap angle A Model No CZ RTC4 For all indoor units Read the Operating Instructio...

Page 7: ...stened with water Air filters Air filters cleaning is needed every two weeks Wash rinse the filters gently with water to avoid damage to the filter surface Dry the filters thoroughly under the shade a...

Page 8: ...gations of mold and bacteria When purchased the nanoe X function is designed to automatically operate If you wish to set to OFF refer to the operating instructions for the remote controller adaptable...

Page 9: ...environment or operating hours mold proliferation or inhibition of mold growth will be changed NOTES z z The internal drying operation is not activated when connecting other than the wired remote con...

Page 10: ...the setting Airflow direction Airflow direction changes while operating Airflow direction cannot be set Airflow direction cannot be changed When air discharge temperature is low during heating operat...

Page 11: ...bleshooting z z Stop the operation immediately and turn the power off Then contact your dealer and report the serial number and symptom You also report if the inspection mark and the letters E F H L P...

Page 12: ...heating performance reduces as outside temperature decreases In the event that heating is not sufficient please use an additional heating appliance Defrosting z z This appliance may start defrosting o...

Page 13: ...035 0 060 0 060 0 075 Sound pressure level High dB A 35 38 40 47 47 49 Medium dB A 31 34 36 44 44 45 Low dB A 27 30 32 40 40 41 Sound power level High dB A 51 54 56 63 63 65 Medium dB A 47 50 52 60 6...

Page 14: ...Cooling Heating dB A 65 67 69 69 70 70 71 71 Unit dimensions H W D mm 996 940 340 1 416 940 340 1 416 940 340 1 416 940 340 Net weight kg 68 99 99 99 Europe Model Name U 71PZH2E8 U 100PZH2E8 U 125PZH...

Page 15: ...ooling mode 10 C 43 C DB Heating mode 15 C 24 C DB Europe Model Name U 100PZ2E8 U 125PZ2E8 U 140PZ2E8 Power source 380 400 415 V 3N 50 Hz Cooling capacity kW 9 0 12 5 14 0 BTU h 30 700 42 700 47 800 H...

Page 16: ...ooling Heating dB A 65 67 69 69 70 70 71 71 Unit dimensions H W D mm 996 940 340 1 416 940 340 1 416 940 340 1 416 940 340 Net weight kg 65 98 98 98 Europe Model Name U 71PZH3E8 U 100PZH3E8 U 125PZH3E...

Page 17: ...Power source 220 230 240 V 50 Hz 380 400 415 V 3N 50 Hz Cooling capacity kW 9 0 12 5 14 0 9 0 12 5 14 0 BTU h 30 700 42 700 47 800 30 700 42 700 47 800 Heating capacity kW 9 0 12 5 14 0 9 0 12 5 14 0...

Page 18: ...onic com Panasonic Corporation 2020 WEB ACXF55 28650 EN DC0920 0 Authorised representative in EU Panasonic Testing Centre Panasonic Marketing Europe GmbH Winsbergring 15 22525 Hamburg Germany OI_00_32...