Symptom

Cause

Action

The air 

conditioner does 

not operate 

although the 

power is turned 

on.

Power failure or after power failure

Press the power ON/OFF button on the remote controller.

The operation (power) button is turned off.

• 

If the breaker is turned off, turn the power on.

• 

If the breaker has been tripped, consult your dealer 

without turning it on.

Fuse blow out.

Contact your dealer.

Poor cooling 

or heating 

performance

The air intake or air outlet of indoor and 

outdoor units is clogged with dust.

Remove the dust.

The fan speed switch is set to “Low”.*

Change to “Medium” or “High”.*

Improper temperature settings

See “Tips for Energy Saving”. (P.5)

The room is exposed to direct sunlight in 

cooling mode.
Doors or windows are open.

The air filter is clogged.

See “Maintenance”. (P.7)

Too many heat sources in the room in 

cooling mode.

Use minimum heat sources and in a short time.

Too many people in the room in cooling 

mode.

Lower the temperature setting or change to “Medium” or 

“High”.*

* Regarding the fan speed control display on the remote controller, see page 13.

If your air conditioner does not work properly even after checking each item of 

“Before Requesting Services” and “Troubleshooting”

z

z

Stop the operation immediately and turn the power off. Then contact your dealer and report the serial number and symptom. 

You also report if the inspection mark   and the letters E, F, H, L, P in combination with numbers appear on the LCD of the 

remote controller.

z

z

Never repair the air conditioner by yourself since it is very dangerous for you to do so.

Before Requesting Services

Emergency Operation

 

„

If any of the following events should occur, operate the unit temporarily by pressing the Emergency 

button of the Indicator.

zz

The remote controller is broken.

 

zz

The batteries are dead (in the case of using optional wireless remote controller).

zz

The remote controller is lost (in the case of using optional wireless remote controller).

 

Pressing the Emergency button will operate under the following conditions.

•   Operation mode : AUTO 

•   Set temperature : 24°C

•   Fan speed : High (

,  )

At this time, the OPERATION lamp of the indoor unit's Indicator lights up.

When stopping the emergency operation, press the Emergency button.

CAUTION

Do not keep pressing the Emergency button. 

If accidentally kept pressing the button, the unit will go into service mode.  

When the Emergency button is pressed once again, the unit returns to stop mode.  

If not returned to stop mode, consult the sales dealer or service center. 

Indicator

Emergency button

OI_00_321038_EN.indb   11

2020/10/27   10:53:20

Summary of Contents for K3

Page 1: ...ructions thoroughly and keep them for future reference Panasonic Corporation 1006 Kadoma Kadoma City Osaka Japan WEB ACXF55 28650 EN Wall Mounted Type K3 Model No INDOOR UNIT Wall Mounted Type K3 S 36...

Page 2: ...comfortable room conditions Use this only for its intended purpose as described in these Operating Instructions Confirm to authorized dealer or specialist on usage of specified refrigerant type Using...

Page 3: ...s must be incorporated in the fixed wiring in accordance with the wiring rules To prevent possible hazards from insulation failure the unit must be grounded WARNING Do not use modified cord joint cord...

Page 4: ...or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children...

Page 5: ...recovery and recycling of old products and used batteries please take them to applicable collection points in accordance with your national legislation and the Directives 2002 96 EC and 2006 66 EC By...

Page 6: ...rating Instructions attached to the Remote Controller The flap display on the remote controller differs from the actual flap angle A Model No CZ RTC4 For all indoor units Read the Operating Instructio...

Page 7: ...stened with water Air filters Air filters cleaning is needed every two weeks Wash rinse the filters gently with water to avoid damage to the filter surface Dry the filters thoroughly under the shade a...

Page 8: ...gations of mold and bacteria When purchased the nanoe X function is designed to automatically operate If you wish to set to OFF refer to the operating instructions for the remote controller adaptable...

Page 9: ...environment or operating hours mold proliferation or inhibition of mold growth will be changed NOTES z z The internal drying operation is not activated when connecting other than the wired remote con...

Page 10: ...the setting Airflow direction Airflow direction changes while operating Airflow direction cannot be set Airflow direction cannot be changed When air discharge temperature is low during heating operat...

Page 11: ...bleshooting z z Stop the operation immediately and turn the power off Then contact your dealer and report the serial number and symptom You also report if the inspection mark and the letters E F H L P...

Page 12: ...heating performance reduces as outside temperature decreases In the event that heating is not sufficient please use an additional heating appliance Defrosting z z This appliance may start defrosting o...

Page 13: ...035 0 060 0 060 0 075 Sound pressure level High dB A 35 38 40 47 47 49 Medium dB A 31 34 36 44 44 45 Low dB A 27 30 32 40 40 41 Sound power level High dB A 51 54 56 63 63 65 Medium dB A 47 50 52 60 6...

Page 14: ...Cooling Heating dB A 65 67 69 69 70 70 71 71 Unit dimensions H W D mm 996 940 340 1 416 940 340 1 416 940 340 1 416 940 340 Net weight kg 68 99 99 99 Europe Model Name U 71PZH2E8 U 100PZH2E8 U 125PZH...

Page 15: ...ooling mode 10 C 43 C DB Heating mode 15 C 24 C DB Europe Model Name U 100PZ2E8 U 125PZ2E8 U 140PZ2E8 Power source 380 400 415 V 3N 50 Hz Cooling capacity kW 9 0 12 5 14 0 BTU h 30 700 42 700 47 800 H...

Page 16: ...ooling Heating dB A 65 67 69 69 70 70 71 71 Unit dimensions H W D mm 996 940 340 1 416 940 340 1 416 940 340 1 416 940 340 Net weight kg 65 98 98 98 Europe Model Name U 71PZH3E8 U 100PZH3E8 U 125PZH3E...

Page 17: ...Power source 220 230 240 V 50 Hz 380 400 415 V 3N 50 Hz Cooling capacity kW 9 0 12 5 14 0 9 0 12 5 14 0 BTU h 30 700 42 700 47 800 30 700 42 700 47 800 Heating capacity kW 9 0 12 5 14 0 9 0 12 5 14 0...

Page 18: ...onic com Panasonic Corporation 2020 WEB ACXF55 28650 EN DC0920 0 Authorised representative in EU Panasonic Testing Centre Panasonic Marketing Europe GmbH Winsbergring 15 22525 Hamburg Germany OI_00_32...