CABLE REQUIREMENTS 

 

 
Another probable cause of a system malfunction is due to improper cable wiring. The 

following cabling requirements MUST be met before the installation to prevent problems. 

 
CABLING (TO BE COMPLETED BE THE GENERAL CONTRACTOR) 

 

*The cable supplied is not FT6 Plenum rating. If the site requires this, please call 
immediately so FT6 rated cable can be provided.  

 

CAT5 DATA COMMUNICATIONS CABLE 

1)

 

CAT5 data communications cable is provided for all Ethernet communication 

runs. 

2)

 

The CAT5 cabling must be home runs from the patch panel to all devices per the 
enclosed specifications. 

3)

 

One CAT5 run must be installed from the patch panel to the burger chute order 

printer.  

4)

 

One CAT5 run must be installed from the drive-thru order taker terminal to the 

drive-thru speaker post for the OCB display. 

5)

 

The CAT5 runs use a standard Ethernet network to an Ethernet Hub Controller. 

6)

 

At each device, leave approximately 6 feet of cable for termination. 

7)

 

Factory 30’ Audio cable must be run from the front runner bump bar to the grill 
monitor.  

 

 
NOT ALLOWED 

x

 

All cabling that is not run in conduit must be kept away from fluorescent 

fixtures, parallel AC runs, motors, etc. 

 

 

Summary of Contents for JS-970 Series

Page 1: ...e in the process of remodeling give this manual to your construction supervisor electrical engineer contractor and electrician so that they may incorporate the system s requirements into their construction plans It is your responsibility to provide the pre installation preparations before the Panasonic Representative arrives The system may not be installed if all the preparations are not completed...

Page 2: ...mp bar to the Grill Monitor as per enclosed specifications Install the kitchen video monitor system KVS MONITOR MOUNT BRACKETS Installation instructions are included with each mounting bracket Please refer to the building plans for mounting locations Cut the 1 HOLES in the counters for the cables to pass through Holes should be center of where the cash register sits approximately 6 in from the fro...

Page 3: ...y use BX instead of conduit 8 Voltage provided in 117 5 VAC 15 9 Ground wires must be INSULATED 10 An ISOLATED ground wire is required and should be run from the receptacles to the main building ground 11 You may also run the ground to a water pipe AS WELL AS the main ground An orange duplex 3 wire grounded receptacle must be installed at the following locations Every touch screen terminal site in...

Page 4: ...cable is provided for all Ethernet communication runs 2 The CAT5 cabling must be home runs from the patch panel to all devices per the enclosed specifications 3 One CAT5 run must be installed from the patch panel to the burger chute order printer 4 One CAT5 run must be installed from the drive thru order taker terminal to the drive thru speaker post for the OCB display 5 The CAT5 runs use a standa...

Page 5: ...lding plans for exact system configuration and equipment placement CAT5e Communications Cable BLUE WIRE Leave 6 of cable at each location for termination QSR will terminate the cables Kiosk T5 Patch Panel Counter T1 Counter T2 Drive Thru Order Taker T4 Drive Thru Cashier T3 Burger Chute Printer The Network rack patch panel is located above the Manager s desk on the top shelf or on the top of the c...

Page 6: ... Please refer to your building plans for exact system configuration and equipment placement IMPORTANT NOTE The CAT5 BLACK cable is for the video monitors E Pic Video Controller Bump Bar CAT5 Black Video Cable CAT5 White Bump Bar Cable 30 Audio Cable The Video Splitter and E Pic Video Controller are usually located above the Manager s desk on the top shelf or on the top of the cabinet Diagram 1b Ki...

Page 7: ...5W 10 125H 1 125D Dimensions are in inches Speaker Post Dimensions 19 0W 52 0H 11 0D Dimensions are in inches Electrical Requirements 24VAC power adaptor at the speaker post Standard CAT5 communications cable It is the contractor s responsibility to have the communications cable run by the on site electrician new stores CAT5 Cable Supplied with speaker post ...

Page 8: ...elphi Drive Thru OCB 192 168 11 71 Port 7 N A Port 7 TM 88IV IP printer 192 168 11 72 Port 8 N A Port 8 Time Shark 192 168 11 73 Port 9 N A Port 9 E pic Video Controller 1 192 168 11 90 Port 10 N A N A Digital Menu Board 1 Dynamic Port 11 N A Port 11 Digital Menu Board 2 Dynamic Port 12 N A Port 12 Digital Menu Board 3 Dynamic Port 13 N A Port 13 Digital Menu Board 4 Dynamic Port 14 N A Port 14 Di...

Reviews: