Communication Objects
ISE SMART CONNECT KNX Panasonic
1-000C-000
© 2019 ise Individuelle Software und Elektronik GmbH
S. 44 / 69
Table 15: Last error
Table 16: Error codes
2 | 102 | 202 | 302
Name
Last error
Function
Provides information on the last error.
Communication object no. TV 1=2
TV 2=102
TV 3=202
TV 4=302
Possible values
Text that contains the number of the error code and an abbrevi
-
ated error description.
Data width
14 bytes
Data point type/data type
16.001 characters
Flags (CRWTUI)
CR-T--
No.
Error code
Description
Possible cause / correction
11
TvComm
Unable to establish communi
-
cation with the TV device.
• The TV device is not connected to
the network.
• The TV device is in standby mode.
13
TvlpConfig
No IP address or host name is
configured.
Configure the IP address or host
name for the corresponding TV
device in the ETS
14
TxOutOfRng
The received value does not
exist.
Check the values entered in commu
-
nication object 30 | 130 | 230 | 330.
Permissible: 0 to 9.
15
ExecuteCmd
Control commands are not
received.
The ISE SMART CONNECT KNX
Panasonic cannot be contacted.
16
GetState
The ISE SMART CONNECT
KNX Panasonic does not
receive an answer to the sta
-
tus query.
The TV device is not contactable.
17
SrcOutOfRng
The entered source is not
assigned.
The value sent for source selection is
not permissible.
23
LnkOutOfRng
The received value does not
exist.
Check the values entered in commu
-
nication object 32 | 132 | 232 | 332.
Permissible: 0 to 9.
24
NoMAC
The TV device MAC address
could not be determined.
The TV device was not switched on
manually for initial commissioning.