manualshive.com logo in svg
background image

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

PolyBlend  

PB200-2 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

02/07 

Siemens Water Technologies Corp. 

PO Box 389 

Bradley, IL 60915 

 

(815) 932-8154 Phone 

(815) 932-0674 Fax 

Содержание PolyBlend PB200-2

Страница 1: ...PolyBlend PB200 2 02 07 Siemens Water Technologies Corp PO Box 389 Bradley IL 60915 815 932 8154 Phone 815 932 0674 Fax ...

Страница 2: ...d Spare Parts 3 Pump Replacement 3 Troubleshooting 4 WARRANTY 5 6 APPENDIX Differential Pressure Switch 7 8 Digital Display Controller REM 1E 9 10 LMI Diaphragm Pump Information 11 14 Bodine AC Motor 15 16 Parker Solenoid Valve 17 20 PARTS LISTS Overall Parts List and Exploded Diagram 21 22 Mixing Chamber Assembly Parts List and Exploded Diagram 23 24 Flowmeter Assembly Parts List and Exploded Dia...

Страница 3: ... s 1 1 6 HP 120VAC 3 6 AMPS INSTALLATION LOCATION Select a location that provides Electrical Supply Potable Water Clean Proximity to the Point of Use Easy Handling and Storage of Polymer Access to Unit Protection Against Severe Weather UNPACKING Examine package contents for damage Report any to freight forwarder Check plastic bag s for contents against individual packing list s NOTE Disregard any ...

Страница 4: ...NOTE For optimum pump performance keep stroke frequency as high as possible This is done by decreasing the stroke length setting More stroke repetition with a shorter length is better than fewer strokes with a long stroke length If stroke length is too short pump prime may be affected Step 7 Adjust water flow at mixing chamber by turning control valve The other control valve should be turned for p...

Страница 5: ...ormal operation once settings are adjusted based on operation parameters the system can simply be turned ON or OFF Special operating instructions for Seasonal operation do not apply EMERGENCY OPERATING INSTRUCTIONS Emergency operating instructions do not apply to Siemens Water Technologies Stranco Products equipment In case of an emergency TURN OFF POWER TO STOP RUNNING DISASSEMBLY REPAIR REASSEMB...

Страница 6: ...gh water flow Make sure pump is in ON position Make sure all water valves supply and discharge are open Take discharge line apart check for blockage and clean if necessary Reduce Back pressure on unit Increase water flow or adjust water monitoring device flow switch DP Switch etc setpoint lower than the desired flow rate Clogged Injection Check Valve Debris or Clumps in Polymer Valve is stuck open...

Страница 7: ...Technologies Corp within thirty 30 days of start up and vii for equipment which is destined for extended storage such equipment must have been stored in accordance with the Storage Requirements detailed in the operation and maintenance manual storage of equipment does not extend the Warranty Period The foregoing warranty does not extend to and Siemens Water Technologies Corp assumes no responsibil...

Страница 8: ...OF THE PURCHASER ARE BASED IN CONTRACT IN TORT INCLUDING NEGLIGENCE OR OTHERWISE WITH RESPECT TO OR ARISING OUT OF THE WORK PERFORMED HEREUNDER LIMITATION OF LIABILITY NOTWITHSTANDING ANYTHING ELSE TO THE CONTRARY SIEMENS WATER TECHNOLOGIES CORP AND ITS SUPPLIERS AND ANY AFFILIATED COMPANIES SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL INCIDENTAL SPECIAL PUNITIVE OR OTHER INDIRECT DAMAGES AND SIEMENS...

Страница 9: ...oint of solution application increases enough to affect flow rate the differential pressure across the rotameter and valve decreases This causes power to be interrupted to the polymer pump and prevents damage to the mixing system caused by extremely high viscosity developing in the mixing chamber NOTICE If system pressure or flow are not adequate investigate the cause of lack of flow For example i...

Страница 10: ...mer pump is disabled 3 Back off the differential pressure knob until the red alarm light goes off The pump starts again 4 4a If you want very close control of flow leave the knob at this setting Atthissetting anyloss of flow asobservedbythe rotameter resultsinthe pumpbeingdisabled 4b If you want to make the system more forgiving prior to shutdown continue to turn the knob another 1 2 turns Thefurt...

Страница 11: ...ough the 4 conductor cable The controller output in the form of contact closures of 80 ms duration triggers the LMI pump In the internal mode output is 0 100 strokes per hour sph or 0 100 strokes per minute spm A touch of the pressure sensitive keys varies the output which is displayed in large easy to read LCD digital format Changes left for longer than 5 seconds are saved in non volatile memory ...

Страница 12: ...6 Siemens Water Technologies Corp REM 1E PART NOS The information provided in this brochure contains merely general descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products An obligation to provide the respective characteristics shall only exist if expressly agreed in terms of ...

Страница 13: ... if your system application requires it Normally calibration is NOT required You will need A watch A calculator Calibrated cylinder with at least 1000 ml capacity Length of hose or tubing same I D as pump ports 1 Maintain all usual connections to the PolyBlend unit except disconnect the polymer suction line at pump input The flow meter and pump setting should be those used for normal service 2 Con...

Страница 14: ...ion on proper zeroing 3 With the unit off unscrew the Liquifram by carefully grasping the outer edge of the Liquifram and turning it counter clockwise Discard old Liquifram disk if so equipped locate behind the Liquifram and check that the size code matches the size code on the replacement Liquifram see illustration 4 Reinstall the disk so alignment pin on the disk if present seats in the recessed...

Страница 15: ...of seal ring and ball See illustration 2 Carefully disconnect one tubing connection and fitting at a time and remove the worn seal ring and ball Carefully loosen sealing by prying side to side using a small screw driver through the center hole of the seal ring 3 Install new seal ring and ball in each location IMPORTANT Note correct orientation 4 Install the new spring valve in the Injection Check ...

Страница 16: ...gns with zero on the nameplate or end of the black or red band 8 Push down on the outer section a snap sound indicates parts are locked together 9 Replace the yellow cap over the outer section of the knob aligning the tabs on the cap with the slots inside the knob Type III Collet Knob Rezeroing and Stroke Knob Disassembly and Assembly 1 Remove yellow cap 2 Hold knob with soft jaw pliers 3 Disconne...

Страница 17: ...15 ...

Страница 18: ...16 ...

Страница 19: ...17 ...

Страница 20: ...18 ...

Страница 21: ...19 ...

Страница 22: ...20 ...

Страница 23: ...0 4681310 BELT GUARD 1 00 EA 21 5551209 LABEL WATER FLOW 2 00 EA 22 5551210 LABEL POLYBLEND 1 00 EA 23 5554000 LABEL SERIAL PLATE 1 00 EA 24 5902001 MOTOR 1 00 EA 25 5963028 NIPPLE SS 1 4 X 4 1 00 EA 26 6020031 NUT 1 4 20 HEX SS 6 00 EA 27 6020962 NUT 8 32 HEX 2 00 EA 28 7771558 SCREW MACH SS PAN HD PHIL 8 32 X 1 2 2 00 EA 29 7772506 SCREW MACH 304SS PAN HD SLTD 10 32 X 3 8 2 00 EA 30 7772508 SCRE...

Страница 24: ...200 D 007 ...

Страница 25: ...NUT ACORN 1 4 20 S S 4 13 6091801 O RING 2 14 6676002 PLATE BAFFLE 1 15 7071201 PULLEY 1 16 7772216 SCREW 10 32 X 1 2 17 7772506 SCREW 10 32 X 3 8 1 18 7802910 SEAL MECHANICAL 1 19 7854303 SHAFT IMPELLER 1 20 8140005 SPACER ROD 2 21 8143011 SPACER 2 22 8603002 STUD 2 23 8603004 ROD 4 24 9412606 TUBE ACRYLIC 1 25 9572304 VALVE INJ CHECK 1 26 9740300 WASHER FLAT 1 4 9 27 8143010 SPACER 1 Factory per...

Страница 26: ...MC 0101 24 ...

Страница 27: ... ITEM PART NO DESCRIPTION QTY UM 1 4291102 FLOWMETER KING 100GPH 1 EA 2 6091301 O RING BUNA N 2 EA 3 1040093 ADAPTER SPUD 1 EA 4 2735634 CONNECTOR TUBE 1 4 FPT X 3 8 OD COMP 1 EA 5 1048401 ADAPTER FLOWMETER 1 EA 6 9579301 VALVE KING 1 EA 25 ...

Страница 28: ...Blank Page 26 ...

Страница 29: ...ING PVC 1 2 FPT 1 5 3570005 ELBOW 90 PVC TXT 3 4 1 6 3585634 ELBOW COMP 90 NP 3 8 OD X 1 4 FPT 1 7 4291102 FLOWMETER KING 100GPH 1 8 4480001 GAUGE PRESSURE 0 160PSI 1 9 5850002 MIXER STATIC 1 10 5960061 NIPPLE PVC 1 2 X CLOSE 1 11 5960064 NIPPLE PVC 1 2 X 2 1 12 5963063 NIPPLE SS 1 2 X 1 1 2 304SS 1 13 6619012 PIPING SUB ASSY MIXER STATIC 1 14 8850004 TEE PVC 1 2 FPT 1 15 8850005 TEE PVC 3 4 FPT 1...

Страница 30: ...OPD 0001 Post Dilution Static Mixer Assembly P N 5860001 28 ...

Страница 31: ...on Supplement Series AA7 Electronic Metering Pump Metering Pump Component Diagram 201 Ivyland Road Ivyland PA 18974 USA TEL 215 293 0401 FAX 800 327 7563 http www Imipumps com 1975 A 08 03 ISO 9001 Certified 29 ...

Страница 32: ...Series AA7 Drive Assembly Exploded View Diagram 30 ...

Страница 33: ...ssembly 115V 1 AA742 AA752 AA762 AA772 AA782 1 AA743 AA753 AA763 AA773 AA783 AA745 AA755 AA765 AA775 AA785 48017 Control Panel Assembly 230 250V 1 AA746 AA756 AA766 AA776 AA786 AA747 AA757 AA767 AA777 AA787 AA741 AA751 48034 EPU w Stroke Adjustment 115V 1 AA742 AA743 AA745 AA746 AA747 AA752 AA753 AA755 AA756 AA757 48035 EPU w Stroke Adjustment 230 250V 1 AA761 48036 EPU w Stroke Adjustment 115V 1 ...

Страница 34: ... 2003 LMI Milton Roy USA All Rights Reserved Printed in USA Specifications subject to change without notice Series AA7 Control Panel Detail Series AA7 Wiring Diagram 32 ...

Страница 35: ...33 ...

Страница 36: ...34 ...

Отзывы: