4.3 PLC Communication Commands
4.3.1 Read Command Parameters
Character recognition (Read)
Command
Response result
CIR
0A02 h
COR
Result output completion=1
CIR+1
1100 h
COR+1
Normal end=0
CIR+2
6
or Error code
CIR+3
Code
COR+2
n
CIR+4,CIR+5
Checker No.
From COR+3
Result
The value of COR+2 is "4" for calendar offset. For reading judgement characters, however, it varies
according to the number of judgement characters. The number of bytes of judgement characters is
stored.
Code
Minimum
Maximum
Judgement characters
1100 h
Calendar Offset
Year
1101 h
-99
99
Month
1102 h
-11
11
Day
1103 h
-30000
30000
Hour
1104 h
-23
23
Min. recognition rate
1111h
0
100
Optical character recognition: Min. recognition rate (Individual) (Read)
Command
Response result
CIR
0A02 h
COR
Result output
completion=1
CIR+1
1100 h
COR+1
Normal end=0
CIR+2
6
or Error code
CIR+3
Code
COR+2
n
CIR+4,CIR+5
Checker No.
COR+3,COR+4
Result
Per judgement character
(‘No.0’)
Per dictionary label (‘1’)
to
COR+149,COR+150
Result
Per judgement character
(‘No.73’)
Per dictionary label (‘+’)
to
COR+161,COR+162
Result
Per judgement character
(‘No.79’)
Code
Minimum
Maximum
Min. recognition rate (Individual)
(Per judgement character)
1112h
0
100
Min. recognition rate (Individual)
(Per dictionary label)
1113h
0
100
Summary of Contents for IMAGECHECKER PV230
Page 9: ...7 Preset menu 1ch Chapter 1 Preset Menu ...
Page 15: ...13 OCR Checker 2ch Chapter 2 OCR Checker ...
Page 61: ...59 Code Reader Checker 3ch Chapter 3 Code Reader Checker ...
Page 86: ......
Page 90: ...88 List of Output to Numerical Calculation Judgement and Data R W 3ch MEMO ...
Page 91: ...89 Communication Commands 4ch Chapter 4 Communication Commands ...
Page 109: ...107 Other Functions 5ch Chapter 5 Other Functions ...