50
Initialize/restart the unit [Initialization]
Click the [Initialization] tab of the "Maintenance" page. (
☞
page 48)
Initialization of the setup data and HTML files of the unit and restarting of the unit can be performed on this page.
[Initialize setup data (Except network setup data)]
Click the [Execute] button to reset the settings to the
default. Note that the network settings will not be reset.
It is impossible to operate the unit for around 3 minute
after the initialization.
[Initialize HTML data]
Click the [Execute] button to reset the HTML files to the
default. It is impossible to operate the unit for around 3
minute after the initialization.
[Initialize setup data and HTML data]
Click the [Execute] button to reset the settings of the
unit and the HTML files to the default. Note that the net-
work settings will not be reset. It is impossible to oper-
ate the unit for around 3 minute after the initialization.
[Camera restart]
Click the [Camera restart] button to restart all the cam-
eras connected to the unit.
After restart, it is impossible to control the cameras for
around 1 minute.
[Unit restart]
Click the [Unit restart] button to restart the unit. The unit
will be inoperable for around 3 minutes after the restart
just as when the power is turned on.
Notes:
• To initialize the network settings (
☞
page 41), do the
following. Turn off the power of the unit. Turn on the
power of the unit by setting the Dip Switch 1 on the
front of this unit to ON, and wait around 90 seconds.
The unit will start up and all the settings including
the network settings will be initialized.
When initializing the network settings (except the
HTTP port number setting) only, set the Dip Switch 2
to ON. After initialization, be sure to set the Dip
Switch 2 to OFF, and turn on the power of the unit
again. (Refer to the provided operating instructions
for further information about the dip switch.)
• When the notification function is on, notification will
be provided to the registered addresses (mail
address or IP address) when the SD memory card
has failed to mount after the restart or when the
inserted SD memory card is locked. (
☞
page 36)