2.7 Connection of Extensions — KX-TDA100/KX-TDA200
Installation Manual
131
Using an Extra Device Port
SLT
Master DPT
Slave DPT
4-conductor wiring cord
Connect pins "T", "R",
"D1" and "D2".
2-conductor wiring cord
Connect pins "T" and "R".
4-conductor wiring cord
Connect pins "T", "R",
"D1" and "D2".
Slave DPT
Master DPT
To SLT
TO MAIN UNIT
/ PABX
TO TEL
TO TEL
TO MAIN UNIT
/ PABX
Cable
Maximum Distance
ø 0.4 mm:
Under 30 m
ø 0.5 mm:
Under 50 m
ø 0.6 mm:
Under 60 m
CAT 5:
Under 50 m
Back View of DPTs
To DLC8/DLC16 card
To DHLC8 card
(for connection of SLT)
To DLC8/DLC16 card
To DHLC8 card
(for connection of SLT)