40
Installing the Appliance
Electrical connection
•
Before connection, check that the mains voltage corresponds to that indicated on
the rating plate fixed to the inside of the appliance. This data must correspond in
order to avoid the risk of damage to the appliance.
•
This appliance is not fitted with means for disconnection from the supply
mains having a contact separation in all poles that provide full disconnection
in under overvoltage category III conditions. Means for disconnection must
be incorporated in the fixed wiring in accordance with the wiring rules and
regulations.
•
Single-phase AC 200-240, 50 Hz electrical system must be used.
•
Check the local utilities for electrical codes applied in the area. Failure to wire the
appliance according to governing rules may result in a hazardous condition.
•
After installation show the customer where the isolating switch for the appliance is
located. This must be easily accessible with the installed appliance.
Installation
•
Veneer or other finish of the furniture the appliance is being built into should be
processed with heat-resistant glue (100°C); otherwise, high temperatures may
cause them to deform.
•
There must be no rear wall fitted to appliance housing.
•
There must be a gap of at least 20 mm between the wall and the back of the unit
to enable adequate air circulation.
•
Level the piece of furniture the appliance was built into with a spirit level.
•
The piece of kitchen furniture the appliance is built into must be secured against
movement, e.g. Attached to the adjacent pieces of kitchen furniture.
•
Align the appliance flush with the units and screw it in place.
•
When attaching the appliance, make sure the screws are not fastened too
strongly as this may damage the furniture or the appliance enamel coating.
•
The ventilation slots and air intake points must not be covered. To ensure that
they remain uncovered also observe the installation instructions of any appliance
installed with this oven.
NOTE
■
Ensure that the connector lead does not become trapped or bent.
■
After installation the connector lead must not be in contact with the back or
the base of the appliance.