CHAPTER 5 SPECIFICATIONS
5-4
5-3 Compact Console
Model No.
HL-C1DP1(-E)-WL
1
Supply voltage
24V DC 10%, incl. ripple 0.5V (P-P)
2
Current consumption
200mA or less
Displaying
element
STN monochrome LCD
Measurement
display range
-999.9999 to 999.9999
Back light
White LED
3
Indicatio
n
Life of LCD
Average 50,000 hours (Note 1)
Operation force
0.5N or less
4
Touch
panel
Life
1,000,000 times or more
5 Ambient
temperature
0 to +50
℃
, Storage: -20 to +60
℃
(No dew condensation or icing allowed)
6 Ambient
humidity
20 to 85%RH, Storage: 10 to 85%RH
(No dew condensation or icing allowed)
7 Vibration
resistance
10 to 55Hz frequency, 0.75mm amplitude in X, Y and Z
directions for 10 min. each
8 Shock
resistance
98m/s
2
,or more, acceleration in X, Y and Z directions
for four times each
9
Superimposed noise
resistance
1,000V(p-p), or more, pulse width 50ns 1.1 s between
power supply terminals
10
Static noise resistance
5,000V or more (at panel surface)
11 Environment
resistance
IP65 (at initial state) (Note 2)
Dust preventive and drip preventive on front face of
panel only (Waterproof packing is used for contact face
of the panel.)
12 Material
Enclosure: PPE
Front panel protective sheet: Polyester
13 Weight
230g
approx.
Notes: 1) Indicates the average life for operation at 25
℃
room temperature.
2) Replace the waterproof packing when reinstalling.
Summary of Contents for HL-C1-WL Series
Page 4: ...2 English Japanese Measuring range indicator Laser emission indicator Warning label ...
Page 11: ...CHAPTER 1 NAME AND FUNCTION OF EACH PART ...
Page 14: ...CHAPTER 1 NAME AND FUNCTION OF EACH PART 1 3 MEMO ...
Page 15: ...CHAPTER 2 INSTALLATION OF SENSOR HEAD ...
Page 16: ...CHAPTER 2 INSTALLATION OF SENSOR HEAD 2 1 2 1 Mounting Dimensions Hl C135C BK10 Unit mm ...
Page 19: ...CHAPTER 3 INPUT TERMINAL BLOCK ...
Page 27: ...CHAPTER 5 SPECIFICATIONS ...
Page 33: ...CHAPTER 6 DIMENSIONS ...