background image

Disclaimer

The applications described in the catalog are all intended for examples only. The purchase of our products described in the catalog shall not be 

regarded as granting of a license to use our products in the described applications. We do NOT warrant that we have obtained some 

intellectual properties, such as patent rights, with respect to such applications, or that the described applications may not infringe any 

intellectual property rights, such as patent rights, of a third party.

No. CE-HGF1-3  Printed in Japan

Industrial Device Business Division

7-1-1, Morofuku, Daito-shi, Osaka 574-0044, Japan

industrial.panasonic.com/ac/e/

ⓒ Panasonic Industry Co., Ltd.

Panasonic Industry Co., Ltd.

Specifications are subject to change without notice.

2022.12

Summary of Contents for HG-F1 Series

Page 1: ...Pinpoint detection from 3 m 9 843 ft away Laser Distance Sensor HG F1SERIES 2022 12 Compact Long Range NEW Certified by NRTL Conforming to FDA regulations ...

Page 2: ... Sensing distance can be numerically set The digital display enables pinpoint setting of the sensing distance in mm Beam axis can be adjusted easily Compact design The beam axis can be adjusted easily by watching the beam spot in the emitted beam spot check mode The compact laser distance sensor unit measures only 20 W 44 H 25 D mm 0 787 W 1 732 H 0 984 D in same shape as our HG C series unit Illu...

Page 3: ...m ø19 685 mil 300 μm 11 811 mil Measuring distance 200 to 400 mm 7 874 to 15 748 in 800 μm 31 496 mil Measuring distance 400 to 600 mm 15 748 to 23 622 in The sensing object used for the HG F1 series was a sheet of white non glossy paper measuring 200 200 mm 7 874 in 7 874 in and the sensing object used for the HG C series was white ceramics The beam diameter was defined as 1 e2 approx 13 5 of the...

Page 4: ...as a 7 segment display and enables the numerical setting of threshold values in mm When multiple sensor units are used the conventional adjuster setting method requires the adjustment of each sensor in actual usage condition With the HG F1 series the distance numeric value set in the first sensor unit can be used as a guideline for setting the distance in the second and other sensor units If the s...

Page 5: ...he beam flashes so that the beam spot can be confirmed clearly even if the sensor unit is installed at a distance This mode facilitates the confirmation of the sensing position Emitted beam spot check mode The beam spot is smaller than that of a conventional adjustable range distance sensor Therefore the sensor resists the effects of the surrounding area and the sensor unit can be installed and po...

Page 6: ...while the zero set is valid If the zero set function is executed while the peak bottom hold function is valid the held measurement value will be reset and the zero set function cannot be set If the peak bottom hold function is enabled while the zero set setting is valid the zero set setting will be cancelled If an error occurs the zero set function cannot be set An external input can be used to se...

Page 7: ...mer Be sure to confirm proper operation with actual machines If the sensors fail to detect consult our sales office in charge Function Extends the signal output for the set timer period Usage Useful when the connected device is slow to respond and the ON time is required to be extended Off delay timer Function Overrides the signal output for the set timer period after the detection Usage Useful wh...

Page 8: ...al Stainless steel SUS304 Two M3 length 25 mm 0 984 in screws with washers SPCC are attached WIRING DIAGRAMS HG F13A A P HG F13A A N 1 Non voltage contact or NPN open collector transistor or External input Invalid 8 V to V DC or open Valid 0 to 1 2 V DC Note Insulate the unused terminals in order to prevent input errors and short circuits 1 Non voltage contact or PNP open collector transistor or E...

Page 9: ...to V DC Input impedance approx 10 kΩ External input function Switchable between zero set teaching or emission stop Default zero set Teaching function Switchable between normal sensing mode 2 point limit or window comparator mode 1 point 2 point 3 point Default Normal sensing mode Timer function Switchable between OFF ON delay OFF delay one shot Default OFF Timer period Switchable between 5 ms 10 m...

Page 10: ...perating position ℓ mm in Center Right Left White Non glossy paper 200 200 mm 7 874 7 874 in N9 to N9 5 reflectance approx 80 Gray Non glossy paper 200 200 mm 7 874 7 874 in N5 reflectance 19 27 White Non glossy paper 200 200 mm 7 874 7 874 in N9 to N9 5 reflectance approx 80 Gray Non glossy paper 200 200 mm 7 874 7 874 in N5 reflectance 19 27 L ℓ L ℓ Sensing distance L mm in White paper Gray pape...

Page 11: ...No Name Function Digital display Red Displays measured values and settings PRO indicator Yellow Lit when PRO mode is set Zero set indicator Yellow Lit while the zero set function is ON Teaching indicator Yellow Lit while teaching is in progress Output operation indicator Orange Lit while control output is ON Laser radiation indicator Green Lit while laser beams are being emitted The emitted beam s...

Page 12: ...t around the detection point the measurement values may be affected if there exist objects with high reflectance around the detecting point If specular reflection light enters the beam receiving part proper measurement may not be possible When the reflectance of a detection object is high be careful in installation When exporting this product to the US affix the provided FDA certificate identifica...

Page 13: ...g method Default 4 Analog output setting Used to select analog output as either analog voltage output or analog current output Default Analog v oUt 5 Analog scaling setting Used to set optional two points as the upper limit value and the lower limit value for performing twopoint correction on the analog output before data is output Set the measured value A as the lower limit value and the measured...

Page 14: ...roperly Check if the sensing distance to be set is within the specification range Er51 The beam emitting part or the beam receiving part is abnormal Turn the power OFF and then ON If the sensor does not recover after the above action consult your Panasonic representative Er90 Er91 Er92 Er93 Er94 Er95 Er96 System error The product could be faulty Please consult your Panasonic representative In case...

Page 15: ...3A A N HG F13A A P Sensor MS HG 01 Simple mounting bracket Optional Material Stainless steel SUS304 Two M3 length 25 mm 0 984 in screws with washers SPCC are attached 9 0 354 3 5 0 138 5 0 197 5 0 197 R20 R0 787 3 5 0 138 2 R3 R0 118 15 5 0 610 15 14 0 551 2 ø3 2 ø0 126 3 2 0 1 2 6 10 R3 R0 118 1 5 0 059 53 2 087 48 5 1 909 58 2 283 22 0 866 37 1 457 22 0 866 18 0 709 30 1 181 90 10 16 0 630 37 1 ...

Page 16: ...obtained some intellectual properties such as patent rights with respect to such applications or that the described applications may not infringe any intellectual property rights such as patent rights of a third party No CE HGF1 3 Printed in Japan Industrial Device Business Division 7 1 1 Morofuku Daito shi Osaka 574 0044 Japan industrial panasonic com ac e ⓒ Panasonic Industry Co Ltd Panasonic In...

Reviews: