– 8-9 –
There two parts in this test item.
(1) RX POWER SCALING FACTOR
Set tester as (a) Test Function: CW (b) RF Gen Power : -60 dBm (c) MS TX Level : 5.
1. Select Band. Click [READ].
2. Select ARFCN (37 for GSM etc.).
3. Set test set : ARFCN : 37; AMP : -60dbm FREQ + 0,0667 MHz.
4. Click [SEND].
5. Click [OFFSET] (in GSM).
6. Set test set for DCS 1800 (ARFCN : 698).
7. Set ARFCN to 698.
8. Repeat (4) and (5) (OFFSET in DCS).
9. Set test set for PCS 1900 (ARFCN : 661).
10. Set ARFCN to 661.
11. Repeat (4) and (5) (OFFSET in PCS).
12. Click [WRITE] (response : NVRAM WRITE OK).
13. Cycle power on handset.
14. Re-"ENTER TEST MODE".
8.3.6. RX Test