background image

9

Installation precautions

Use the dedicated AC adapter and power cable provided 
with the unit.
Connect the AC adapter and power cable to the power inlet 
securely.
The power cable supplied with this unit must always be used 
with this unit. The unit cannot be used with a power cable 
which is not supplied with the unit. Neither can the power 
cable supplied with the unit be used with any other device.

Installing the AC adapter

p

p

Do not place the AC adapter in direct contact with a floor 
or any other such surface. An extreme danger is posed 
by water pooling on the surface as a result of leaking 
rainwater or some other reason. 
Anchor the AC adapter securely to a surface on which no 
water, dust, etc. will collect.

p

p

Secure the adapter firmly so that there will be no chance 
that it will fall off or fall down. 
Secure it using a strength which can withstand the mass 
of the AC adapter.

Install the accessory AC adapter near the main power 
outlet, and position it in such a way that its power plug 
can be plugged into and unplugged from the outlet easily.
If the AC adapter is to be connected where dust collects, 
remove the dust and dirt from the power plug at regular 
intervals as a measure to prevent tracking.

Power switch
This unit does not have a power switch. The power turns 
on when its power plug is connected to a power outlet. 
When the power is turned on, the pan, tilt, zoom and 
focusing operations are performed. Before proceeding with 
maintenance, be absolutely sure to disconnect the power 
plug from the power outlet.

Connecting the power cable
Be absolutely sure to connect the power cable of the 
AC adapter through a circuit breaker using one of the 
following methods.

(1) Connect the power cable through a power control unit.
(2)  Connect the power cable to a circuit breaker in a 

power distribution panel with a contact distance of 
3.0 mm or more. 
Use a circuit breaker which is capable of shutting 
off all the poles of the main power supply with the 
exception of the protective ground conductor.

(3)  Install the AC adapter near the power outlet, and 

connect it through the power plug.

If there is a possibility of noise interference
Either wire the cables so that the power cable (ceiling light 
cord) of AC 220 V or more, and the signal cable are placed 
at least 1 m apart. Alternatively run each cable through its 
own metal conduit. (The metal conduits must be grounded.)

Radio signal interference
If the unit is positioned near a TV or radio transmitting 
antenna or a strong electrical field or magnetic field (such as 
that generated by a motor, transformer or power lines), its 
images may be distorted and/or the images may be affected 
by noise.

When connecting the cables, ensure that the connector 
areas will not be subject to any load.
Doing so may cause malfunctioning.

Allowing the generated heat to escape
This unit allows the heat generated inside to escape from its 
surfaces.
Do not install the unit in a location where it will be 
surrounded by walls or other surfaces and where heat will 
be trapped. In addition, the heat is dissipated to the bottom 
panel which will warm up over time: This is normal and not 
indicative of any trouble.

IMPORTANT

p

p

The product name and its electrical ratings are 
marked on its bottom panel.

Summary of Contents for GP-VD130E

Page 1: ...re use Operating Instructions Basics HD Communication Camera Model No GP VD130E Installation Instructions provided For instructions on how to operate this HD Communication Camera and how to establish its settings refer to the operating instructions of the HD Visual Communication Unit to be connected ...

Page 2: ...ier for further information Information on Disposal in other Countries outside the European Union This symbol is only valid in the European Union If you wish to discard this product please contact your local authorities or dealer and ask for the correct method of disposal DO NOT REMOVE PANEL COVERS BY UNSCREWING To reduce the risk of electric shock do not remove the covers No user serviceable part...

Page 3: ...rensstemmelse med følgende normer eller andre normgivende dokumenter som følger bestemmelsene i direktivene 2006 95 EC og 2004 108 EC This appliance is supplied with a moulded three pin mains plug for your safety and convenience Should the fuse need to be replaced please ensure that the replacement fuse is of the same rating and that it is approved by ASTA or BSI to BS1362 Check for the ASTA mark ...

Page 4: ...e that the unit is installed correctly p p This manual explains how to install the unit For details on how to operate the unit and select its settings refer to the operating instructions of the HD Visual Communication Unit to be connected To read PDF files you will need Adobe Reader which is available from Adobe Systems Connections 15 Connections to the HD Visual Communication Unit and AC adapter ...

Page 5: ...rademarks or registered trademarks of HDMI Licensing LLC in the United States and other countries p p Adobe Acrobat Reader and Reader are either registered trademarks or trademarks of Adobe Systems Incorporated in the United States and or other countries w wAbout copyright and licence Distributing copying disassembling reverse compiling reverse engineering and also exporting in violation of export...

Page 6: ...D Visual Communication Unit p p The functions and settings can also be switched easily while viewing the menu screens These switching operations can be performed only while the HD Visual Communication Unit is operating Easy operation of unit enabled by its integration with a high performance pan tilt head unit p p Operations at the high speed of 90 s or more p p Wide rotational angles with a panni...

Page 7: ...7 Accessories Check that the following accessories are present and accounted for Getting Started 1 Warranty 1 Power cable 1 8 m 2 AC adapter 1 Use the power cable that is suited to your locality ...

Page 8: ...n locations including places such as under the eaves of a building where the unit would be directly exposed to rain or water p p In locations such as kitchens where there are high concentrations of steam and grease p p In outdoor locations or hot places where the temperature will exceed 40 C p p In cold locations where the temperature will drop below 0 C p p In locations where the humidity will ex...

Page 9: ...power outlet Connecting the power cable Be absolutely sure to connect the power cable of the AC adapter through a circuit breaker using one of the following methods 1 Connect the power cable through a power control unit 2 Connect the power cable to a circuit breaker in a power distribution panel with a contact distance of 3 0 mm or more Use a circuit breaker which is capable of shutting off all th...

Page 10: ...s of the MOS sensor are exposed to spotlights or other strong lights blooming a phenomenon where the edges of strong lights become blurred may occur Bright subject Blooming Concerning the colour reproduction of MOS sensors Depending on the colour tones of the subjects the colour reproduction may deteriorate This is normal and not indicative of any trouble What happens with high brightness subjects...

Page 11: ... in an environment with high concentration of moisture or dust since these conditions will damage the internal parts Disposal of the unit When the unit has reached the end of its service life and is to be disposed of ask a qualified contractor to dispose of the unit properly in order to protect the environment When using the automatic functions p p When using the automatic white balance setting au...

Page 12: ...unit Remote control signal receiver HD Visual Communication Unit operations Camera operations p p The figure does not show the HDMI cable q qRemote control operations using the IR repeater function The signals of the remote controller are received by the receivers of the camera this unit and the operations of the HD Visual Communication Unit etc are performed via the IR system cable HD Visual Comm...

Page 13: ...on 4Lens unit This rotates in the up and down direction 5HDMI connector HDMI This is the HDMI video output connector 6IR system service connector IR SERVICE Connect the IR system cable to this connector See page 15 The connector is also used for maintenance purposes 7Anti theft wire mounting hole Use this hole to attach the wire bracket 8 DC IN connector 16V IN Connect the AC adapter supplied with...

Page 14: ...ra mounted on it Attach the tripod to the threaded hole for mounting the camera on the camera s bottom panel Place the tripod on a completely flat and level surface Tighten the screw by hand to mount the tripod securely Do not tighten the screw by rotating the camera body Doing so may cause malfunctioning Use screw for mounting the tripod that satisfy the following standard Screw for mounting trip...

Page 15: ...signal receivers IR repeater function For details on the IR repeater function refer to page 12 HD Visual Communication Unit Rear panel connector area Transmitter Point the transmitter at the remote control signal receiver and attach it to the mounting position IR system cable Use a strip of double sided tape to adhere the cable to the equipment or shelf Mounting position Remote control signal rece...

Page 16: ...to the camera perform one or more remote control operations and check that the HD Visual Communication Unit does not operate in response Check that the signals of the remote controller are not being received directly If the HD Visual Communication Unit does operate select another installation location This unit Leave this end of the cable disconnected p p The figure does not show the HDMI cable HD...

Page 17: ... the unit For details of the screen standby function refer to the operating instructions of the HD Visual Communication Unit Power ON mode Status display lamp Green Status in which the camera has been connected properly to the HD Visual Communication Unit and can be controlled The transition of the status of the camera mode is linked with the status of the HD Visual Communication Unit Linkage with...

Page 18: ... OFF Digital Zoom OFF Preset number 1 9 Pan Tilt Position Center Brightness Auto White Balance Auto Focus Auto Home Position Fixed at preset number 5 The camera moves to this position first when its power is turned on p p For details on how to operate the unit and select its settings refer to the operating instructions of the HD Visual Communication Unit to be connected ...

Page 19: ... If the status display lamp does not blink even when the remote controller is operated near the remote controller signal receiver it means that the batteries have run down Replace the batteries Operating instructions of the HD Visual Communication Unit p p Is there a fluorescent light or plasma monitor near the unit and if so is the remote controller signal receiver exposed to its light p p Are th...

Page 20: ...e HD Visual Communication Unit The subject is not brought into focus during zooming when the manual setting is used for the focus p p Was the focus adjusted at the Tele end First adjust the focus at the Tele end where the focusing accuracy is higher and then proceed with the zooming Operating instructions of the HD Visual Communication Unit p p Under some operating conditions it may be hard to bri...

Page 21: ...sh is fired during shooting only the top or bottom of the screen becomes lighter p p With a MOS image sensor the shooting timing differs slightly between the top left and bottom right of the screen This means that when the flash is fired the bottom of the screen will become lighter in the field concerned and the top will become lighter in the next field This is normal and not indicative of any pro...

Page 22: ...22 Appearance Unit mm 100 139 133 127 ...

Page 23: ...RMANCE Camera unit Imaging sensors 1 3 type Full HD MOS Lens Motorized 3 zoom F1 2 to 2 0 f 3 0 mm to 9 0 mm Focus Switching between auto and manual Focus distance Entire zooming range 3 0 m Horizontal resolution 850 TV lines Typ Centre area White balance function Provided Output format HD 1080 50i Pan tilt head unit Pan tilt operation speed Max 90 s or more Panning range 100 Tilting range 20 Quie...

Page 24: ... Panasonic System Networks Co Ltd 2012 F1112 0 PGQP1415ZA ...

Reviews: