ALL-LOCK function
All keys on the operation panel are locked when the channel shift key is pressed for 3 sec. or more (unless CH-SELECT is set on 'PANEL').
To release the lock, press the channel shift key for 3 sec., or more, again.
٨
Response time
The controllers
GD-C1
and
GD-C2
automatically select the most suitable signal processing method, according to the material and thickness of
the sensing object. Depending on the selected signal processing method, the response time is also automatically determined as either '5ms or
less', or '30ms or less'.
Further, when controller
GD-C3
is used, the response time is 5ms or less.
The response time of the controllers,
GD-C1
and
GD-C2
, can be confirmed by the following procedure.
Ԙ
ԙ
Press '0-ADJ. key' in RUN mode'.
The channel display shows an alphanumeric character that represents the re-
sponse time in the right.
or
5ms or less
30ms or less
Other than
the above
٨
GD-C2
can feed in the set level data into a PC or PLC memory using RS-232C serial communication and retrieve it whenever required.
In this case, the taught data should be stored in the prescribed channel.
Transmission specifications
Baud rate: Selectable from 300, 600, 1,200, 2,400, 4,800, 9,600, 19,200, or 31,250 bits/sec.
Format: Data bits ...................
Parity check ..............
Stop bits ....................
Terminal code ...........
7 bits or 8 bits
None or Enable
Even or Odd
1 bit or 2 bits
CR or ETX
RS-232C DATA TRANSMISSION (GD-C2 only)
7
Command
If the sent command is ineffective,
GD-C2
returns 'Not Available'.
All characters including send and response statements are based on ASCII code.
All commands used to communicate with
GD-C2
are classified into three groups: write command, read command, and others (ASCII coded data
communication).
Notes: 1)
2)
3)
The
GD
series automatically selects the most effective sensing process
according to the material and thickness of the object.
The process number ranges from '00 to 47' in decimal number system.
Both the one-sheet level data and the two-sheet level data are repre-
sented by decimal numbers from '0 to 4,095',
The data information, information on the presence of data, the sensing
mode, etc., is represented by decimal numbers from '00 to 63'.
SCH
SRC 1 to 8
SAC
Usage
Statement
Assign the channel and write data into it.
The command format is the same as for SCH.
Write the date into the channel presently designated.
SCH
˴˴ٌٌٌٌ˴٤٤٤٤˴غغ
+ CR (ETX)
Space or
comma (, )
Attribute (Note 3)
One-sheet level data (Note 2)
Two-sheet level data (Note 2)
Process No. (Note 1)
Write the data into all channels.
SAC
˴˴ٌٌٌٌ˴٤٤٤٤˴غغ˴˴ٌٌٌٌ˴٤٤٤٤˴غغ
̖̖˴˴˴ٌٌٌٌ˴٤٤٤٤˴غغ
+ CR (ETX)
Channel 1
Channel 2
Channel 8
Ԙ
Write command
Syntax: Statement + Numerical data + CR (ETX)
After the write command is sent, Statement + CR(ETX) is returned
by
GD-C2
to confirm the communication.
<Type of commands>
Note: Both the one-sheet level data and the two-sheet level data are represented
by decimal numbers from '0 to 4,095',
Note: Make sure to turn the power off when set the parameter DIP switch. When turn the power on, the set contents are reflected.
After setting, be sure to mount the protective cover.
RCH
RRC 1 to 8
RAC
RAD
OUT 0
OUT 1
Read the data of the presently designated channel.
Send: RCH + CR (ETX)
Response: RCH
˴˴ٌٌٌٌ˴٤٤٤٤˴غغ
CR (ETX)
Read data of all channels.
Send: RAC + CR (ETX)
Response: RAC
˴˴ٌٌٌٌ˴٤٤٤٤˴غغ˴˴ٌٌٌٌ
٤٤٤٤˴غغ˴̖̖˴˴˴ٌٌٌٌ˴٤٤٤٤˴غغ
CR (ETX)
Channel 1
Channel 2
Channel 8
Read only the sensing level data of the present channel.
Send: RAD + CR (ETX)
Response: RAD
˴ڏڏڏڏ
+ CR (ETX)
Sensing level data (Note)
Read the present sensing condition.
Send: OUT 0 + CR (ETX)
Response: OUT 0
˴ٖ
+ CR (ETX)
(0: Zero-sheet sensing, 1: One-sheet sensing, 2: Two-sheet sensing)
Sensing condition
Read the present sensing level (the number of LEDs which light up).
Send: OUT 1 + CR (ETX)
Response: OUT 1
˴٠
+ CR (ETX)
(0 to 7)
Sensing level
Usage
Statement
Assign the channel and read its data.
Send: RRC 1 to 8 + CR (ETX)
Response: RRC 1 to 8
˴˴ٌٌٌٌ˴٤٤٤٤˴غغ
CR (ETX)
ԙ
Read command
Syntax: Statement + CR (ETX)
<Type of commands>
Parameter setting
Set the paraments with the DIP switches on
GD-C2
.
Prameter DIP switch
ON
1
3
4
5
6
7
8
2
Terminal code
Stop bits
Parity Even / Odd
Parity None / Enable
Data bits
Baud rate
1
300
600
1,200 2,400 4,800 9,600 19,200 31,250
ON
OFF
ON
OFF
ON
OFF
ON
OFF
2
ON
ON
OFF OFF
ON
ON
OFF OFF
3
ON
ON
ON
ON
OFF OFF OFF OFF
Switch
No.
Parameter
Baud rate
1
2
3
ON
OFF
Data bits
4
7 bits
8 bits
Parity check
5
Enable
None
6
Even
Odd
Stop bits
7
1 bit
2 bits
Terminal code
8
CR
ETX
Switch No.
Bits/sec.