10
Product Outline
1
Storage environment
Temperature: -20–70
°
C, Humidity: 10–90% RH (no condensation)
Mass (Weight)
3,000 g
External dimensions
44 mm (Height) × 330 mm (Width) × 230 mm (Depth) (Excluding
protruding sections)
Operating environment
Temperature: 0–50°C, Humidity: 20–80% RH (no condensation)
*If it is used beyond the operating environmental temperatures,
then the protective devices will start working and the Ethernet
Switch power will be shut off.
Others
STP/RSTP/MSTP
Supports the IEEE802.1X authentication (MAC-based, port-based)
MAC authentication, WEB authentication, Triple authentication,
STEP authentication, IEEE802.1X supplicant,
Port monitoring, Ring protocol, IGMP snooping,
Loop detection/shutoff function, Storm control, DSCP mapping function,
Login RADIUS function, DHCP client function,
PoE scheduler function, PoE auto reboot function,
Port grouping function, Multi-cast address group registration function
Power supply
AC 100-240 V, 50/60 Hz, 5.0 A
Power consumption
Normally, Max. 315 W (23.1 W when not supplying power), Min. 14.7 W
1.3 Accessories
Installation Guide (this document)
1 (*)
Rubber foot
4
Rack mount bracket (for 19-inch rack)
2
Screw (for 19-inch rack)
4
Screw (for fixing the mount brackets to the Ethernet Switch)
8
Power cord
1
[Optional accessories]
PN54022-XX 1000BASE-SX SFP Module(i)
PN54024-XX 1000BASE-LX SFP Module(i)
The XXs are identical to the intended nation of delivery codes.
Please be sure to confirm the content.
Please contact our distributor if any of the contents are insufficient.
1.4 Basic operation
This Product does not have a power ON/OFF switch. Connect the supplied power
cord to this Ethernet Switch and connect the other end into an electric outlet.
This Ethernet Switch operates at AC 100 - 240 V (50/60 Hz).
When power is supplied, all the LEDs are turned ON.
Then, POWER LED (Power) lights in green, STATUS/ECO LED (Status/ECO mode)
lights in orange, and self-diagnosis of hardware is executed.
On completion of self-diagnosis, POWER LED (Power), STATUS/ECO LED
(Status/ECO mode), TEMP LED (Temperature sensor) and FAN LED (Fan sensor) light
in green, and the Ethernet Switch starts operation as a Ethernet Switch.
As this Ethernet Switch succeeds in communicating with a terminal connected to
each port, LED of the port lights up.
When the terminal is not operating normally, for example when power is not
supplied to the terminal, LED is not lighted.
Quantity
* For the configuration and management method, please see the PDF version
Operating Instructions on Panasonic’s website.
[Power Cord]
The following power cord is supplied as per the intended nation of delivery.
Locale
Australia
New Zealand
250 VAC 10 A
AS/NZS 3112
-
Product Number
PN261693D-NZ
Power Cord Rating FUSE Rated Current
Plug Type