Basic Instructions for the Use of This Product

  For inspection and/or repair, consult the retailer.

  Use commercial power supply from a wall socket, which is close and easily accessible to this 

Ethernet Switch.

  Unplug the power cord when installing or moving this Ethernet Switch.

  Unplug the power cord when cleaning this Ethernet Switch.

  Use this Ethernet Switch within the specifications. Deviation could lead to malfunction.

  Do not touch the twisted pair cable modular metal terminals which are connected to RJ45 

connectors (twisted pair ports) or the connectors, nor place them near electrically-charged 
objects. Static electricity could lead to equipment failure.

  Do not put the modular plug of the connected twisted pair cable on objects that can carry 

static charge, such as carpet. Do not place it in the proximity. Static electricity could lead to 
equipment failure.

  Do not put a strong shock, including dropping, to this Ethernet Switch. Deviation could lead 

to equipment failure.

  Before connecting a console cable to the console port, discharge static electricity, for example 

by touching metal appliance (do not discharge by touching this Ethernet Switch).

  Please use this Ethernet Switch in places where the ambient temperatures range from 0 to 

50°C and, when the fan setting is set to Low2, or Min and it is used, use it in areas where the 
ambient temperatures range from 0 to 40°C.

  Do not store, nor use this Ethernet Switch in environments which possess the characteristics 

listed below.

  (Store and/or use this Ethernet Switch in the environment in accordance with the 

specification.)

-  High humidity. Possible spilled liquid (water).
-  Dusty. Possible static charge (such as carpet).
-  Under direct sunlight.
-  Possible condensation. High/low temperature exceeding the specifications environment.
-  Strong vibration and/or strong shock.

  Failure to satisfy the conditions above may result in a fire, electric shock, equipment failure, 

and/or malfunction. Such events are not covered by the warranty.

*If it is used beyond the operating environmental temperatures, then the protective devices 

will start working and the Ethernet Switch power will be shut off.

  Do not block the ventilator of the Ethernet Switch.

  Blocked ventilator induces the heat accumulation inside, causing equipment failure and/or 

malfunction.

  If used at a temperature out of the operating temperature range, deviation could lead to 

malfunction.

 

Operation is not guaranteed if a module other than the optional SFP extension modules 
(PN54022/PN54024) is inserted into the SFP extension slot.

  For the latest information about compatible SFP extension modules, check our website.

  When using two Ethernet Switches, do not stack them. When you place them side by side, 

allow for a space of 20 mm or more between them. This space is not necessary if you use 
supplied  connection brackets.

  When Ethernet Switches mounting to rack, leave a minimum of 20 mm space between them.

1. Please note that Panasonic shall not bear any liability whatsoever for any damages 

(this shall include, but is not limited to, lost earnings, lost opportunities, etc.) 

which were generated in relation to damages caused by operations and usage, 
or the inability to use this Ethernet Switch, whereby the customer does not follow 
this Installation Guide.

2. The contents described in this document may be changed without prior notice.
3. For any question, please contact the retailer where you purchased the product.

7

Summary of Contents for GA-ML24TCPoE+

Page 1: ... customers are not covered by the warranty C0620 20222 Printed in Japan GA ML24TCPoE Model No PN262492 TH PN262492 MY PN262492 ID PN262492 SG The instruction manuals Menu Version CLI Version Web Version latest firmware and SDN application ZEQUO assist Plus can be downloaded from the following URL https panasonic co jp ew pewnw english datadownload index html 2 12 7 Higashi Shimbashi Minato ku Toky...

Page 2: ...res 1 2 Specifications 1 3 Accessories 1 4 Basic operation 2 Part Names and Functions 2 1 LED display change 2 2 PoE power supply function 3 Installation and Configuration 3 1 Grounding Cable Connection 3 2 Mounting to rack 3 3 Configuration of IP address Basic Troubleshooting 3 7 8 8 9 11 11 12 15 17 18 18 19 20 22 ...

Page 3: ...ead to fire electric shock and or equipment failure Do not damage the power cord Do not bend too tightly stretch twist bundle with other cord pinch put under a heavy object and or heat it Damaged power cord could lead to fire short and or electric shock Do not unplug nor plug in the power plug with wet hands Deviation could lead to electrical shock and or equipment failure Do not insert or drop fo...

Page 4: ...et which is connected to the ground If the outlet is not connected to a ground connect the ground cable to the ground terminal screw Connect the power cord firmly to the power port Otherwise this might cause electrical shocks and malfunctions Unplug the power cord if the STATUS ECO LED Status ECO mode or FAN LED Fan sensor blinks in orange system fault Deviation such as keep connecting for a long ...

Page 5: ...reful in regards to environmental restrictions whereby the Ethernet Switch can be used Please isolate the business power lines and communication lines Isolate distribution lines and other distribution lines and low current power lines optical fiber cables metallic water conduits and gas conduits etc Noise may be generated in the communication lines which might cause communication glitches Do not c...

Page 6: ...air cable leading to malfunction If you connect such a device it is strongly recommended that you install a surge protective device SPD on the twisted pair port side of this Ethernet Switch A lightning surge current voltage may be conducted to this Ethernet Switch through the power supply or ground wire connected to the power port leading to malfunction If a lightning surge current voltage may flo...

Page 7: ...e spilled liquid water Dusty Possible static charge such as carpet Under direct sunlight Possible condensation High low temperature exceeding the specifications environment Strong vibration and or strong shock Failure to satisfy the conditions above may result in a fire electric shock equipment failure and or malfunction Such events are not covered by the warranty If it is used beyond the operatin...

Page 8: ... configuration changes and verifications of the Ethernet Switch Remotely configure the PoE settings for each port Ports 1 to 24 The connection status for each port is detected by the power saving mode and it can suppress the power consumption to required volumes when not linked up Factory default deactivated Rapid Spanning Tree Protocol is supported allowing to build a system with redundancy The I...

Page 9: ...sion Link Aggregation IEEE802 3ad Configurable up to 14 groups Max 8 ports per group VLAN IEEE802 1Q tagging VLAN protocol compatible Max 256 groups including the default VLAN Port based VLAN Internet Mansion function QoS IEEE802 1p compatible Supports 8 priority queues Management method ZEQUO assist Plus SNMP v1 v2c v3 Telnet SSH v2 Console WEB control screen Power supply function Ports 1 to 24 s...

Page 10: ...Switch power will be shut off Others STP RSTP MSTP Supports the IEEE802 1X authentication MAC based port based MAC authentication WEB authentication Triple authentication STEP authentication IEEE802 1X supplicant Port monitoring Ring protocol IGMP snooping Loop detection shutoff function Storm control DSCP mapping function Login RADIUS function DHCP client function PoE scheduler function PoE auto ...

Page 11: ...OWER LED Power lights in green STATUS ECO LED Status ECO mode lights in orange and self diagnosis of hardware is executed On completion of self diagnosis POWER LED Power STATUS ECO LED Status ECO mode TEMP LED Temperature sensor and FAN LED Fan sensor light in green and the Ethernet Switch starts operation as a Ethernet Switch As this Ethernet Switch succeeds in communicating with a terminal conne...

Page 12: ...erminal screw 10 100 1000BASE T ports ports 1 28 Ports 1 to 24 can supply PoE power confirming with IEEE802 3at af Devices such as 10 100 1000BASE T terminal hub repeater bridge and Ethernet Switch can be connected to this port Install the device so that the length of twisted pair cable CAT5e or above becomes 100m or less SFP extension slot ports 25 28 Install SFP module It becomes exclusive usage...

Page 13: ...ort s power supply is exceeding the upper limit or the total power supply of the Ethernet Switch is exceeding 96 W TEMP LED Temperature sensor Green Light The system is normally operating Orange Blink The temperature exceeded the set threshold of the internal temperature sensor Set threshold of the internal temperature sensor 57 C factory default FAN Fan sensor LED Green Light The system is normal...

Page 14: ...lex or no device is connected Green Light Orange Blink Off LOOP HISTORY Green Light Loop has been detected within the last 3 days Off No loop detection history It is shut off via the loop detection and shutoff function storm control or the BPDU guard PoE are being supplied power Power is not being supplied or the PoE receiving equipment are not connected Also it is set in the ECO mode Single port ...

Page 15: ...tically returns to a Base mode Status mode or ECO mode The Base mode is maintained even after the power is turned OFF Indication on the front panel and LED lamps You can display the following items using the LED display switch button Display for the connection with a connected terminal Status mode Display for the 1000 Mbps transmission rate GIGA mode Display for the full duplex or half duplex tran...

Page 16: ...ode The Base mode is maintained even after the power is turned OFF LED lamps for each mode and LED lamps for ports 1 to 28 correspond as shown in Table 1 see page 14 Turns on the port LED with a orange light when a loop occurs in the corresponding port The Loop shutoff mode has the following 2 types of modes Block mode factory default When loops are detected the port statuses are automatically blo...

Page 17: ...total power supply of the Ethernet Switch is exceeding 96 W 1 When configured IEEE802 3at factory default Exceeds 15 4 W when configured IEEE802 3af When the requested power supply for the Ethernet Switch is exceeded and it gets overloaded the power supply to the low priority ports is stopped and the port LEDs right of the ports whose power supply have been stopped blink in orange The priority set...

Page 18: ... cable must be no less than 18 AWG and the length is 50 cm 3 The ground installed screw shall comply with 3 5mm minimum in nominal thread diameter and engage at least two complete threads into metal chassis with appropriate fixing hardware like washer 4 The grounding cable shall not be removed during normal operation servicing or maintenance 5 Installation steps Step 1 Ensure the detachable power ...

Page 19: ...xing the mount brackets and the Ethernet Switch Fix the mount brackets to the four holes on each side of the Ethernet Switch using the screws Then securely install the Ethernet Switch on the rack using the four provided screws for mounting on a 19 inch rack or screws provided with the rack ...

Page 20: ...n 3 enable configure config interface vlan 1 config if ip address 192 168 1 254 255 255 255 0 5 Enter the following command to save the setting config if exit config exit copy running config startup config 6 Since the following screen is displayed enter Y and the settings will be saved Screen 4 Confirm that the settings have been normally saved Screen 5 7 After configuring start with the terminals...

Page 21: ... ML24TCPoE config if ip address 192 168 1 254 255 255 255 0 GA ML24TCPoE config if GA ML24TCPoE Product Number PN262492 Firmware Version x x x xx MAC Address 00 50 40 xx xx xx Serial Number xxxxxxxxxxx UserName manager Password GA ML24TCPoE enable GA ML24TCPoE configure GA ML24TCPoE config interface vlan 1 GA ML24TCPoE config if ip address 192 168 1 254 255 255 255 0 GA ML24TCPoE config if exit GA...

Page 22: ... T 100BASE TX or 1000BASE T standard Auto negotiation may have failed Check the port settings of this Ethernet Switch or the terminal settings Is the correct Port LED display mode selected using the LED display switch button The Port LED left lights in orange Loop is occurring By removing the loop orange LED will be turned off LOOP HISTORY LED Blinks in green This is to notify that there is a port...

Page 23: ...ly may not be possible depending on the installation environment In such cases use a UTP cable Is a CAT5e or better straight cable RJ45 8 8 used Is the cable connected to the port 1 24 that supports PoE power supply Ensure that either the port alone or the entire equipment is not overloaded Is the Powered Device connected to the port compliant with the IEEE802 3at standard or IEEE802 3af standard ...

Reviews: