![Panasonic FY-150ZDY8 Operation Instructions Manual Download Page 18](http://html1.mh-extra.com/html/panasonic/fy-150zdy8/fy-150zdy8_operation-instructions-manual_4085513018.webp)
安装参考图 施工方法
①
Install 4 ceiling suspension bolts (separately buy:M10)
●
Please align the suspension angle of main unit with ceiling suspension bolts.
Installation of main unit and air duct
施工方法
安装主机和风道
安装
4
个天花板吊装螺栓(另购:
M10
)
请将主机吊装角度与天花板吊装螺栓对齐。
Unit:mm
单位
:mm
Model
A
FY-150ZDY8
FY-250ZDY8
型号
B
810
525
810
655
FY-350ZDY8
FY-500ZDY8
978
860
1018
960
FY-650ZDY8
FY-800ZDY8
1132
940
1250
940
FY-01KZDY8A
1250
1190
吊装点尺寸
吊装点尺寸
A
B
Suspension point dimension
Suspensi
on
poi
nt
di
m
ensi
on
●
Please adjust the length of ceiling suspension bolt to ensure the distance between the downside of unit
and ceiling is over 25mm, the distance between the upside of unit and the mounting face of ceiling
suspension bolts is over 20mm.
请调整天花板吊装螺栓的长度,确保机器下部与天花板之间的距离应确保在25
mm
以上,机器上部与天花板吊
装螺栓安装面之间的空间应确保在20
mm
以上。
above 20mm
above 20mm
20mm
以上
20mm
以上
②
Install the ceiling suspension part to its bolts.
●
Please correctly install the direction of outside
air duct.
●
Never fail to install the direction of unit
(ensure the ceiling suspension is above).
●
Install the unit horizontally.
●
Fix the screws and washers (separately buy).
Ceiling suspension part
Nut
Washer
螺母
垫片
吊装部件
将天花板吊装部件安装到其螺栓上。
请正确安装外部风道的方向。
永远不要安装单元的方向(确保天花板吊装在
上面)。
固定螺钉和垫圈(单独购买)。
水平安装设备。
③
Seal the junction of an adaptor and a duct by
adhesive tape or seal tape (separately buy) to
prevent any air leakage.
●
Please don’t touch the fan motor by hand during
the air duct construction.
●
Install the ducts (2) connected with outside shall
incline to outside. (gradient: 1/100~1/50)
●
Conduct the insulation to outside of two ducts
connected with outdoor.
(suggested material: glass wool, thickness 25mm)
用铝箔胶带(单独购买)密封接口和管道的连接部分,
以防止漏气。
在风道结构中,请勿用手触摸风轮电机。
安装与外部连接的管道(
2
)应向外倾斜。
(
坡度:
1/100~1/50)
outside air duct, exhaust air duct
gradient
adhesive tape
坡度
insulation material
(Adaptor and aluminum tape is
requested to insulate.)
绝缘材料
(
接口、铝箔胶带也要求绝热)
室外新风管道,室外排风管道
铝箔胶带
室外侧管道必须安装防止结露的绝缘材料。
(
材料: 玻璃棉, 厚度
25mm)
18