11

PRO MODE

 

● When MODE indicator: PRO (yellow) lights up, PRO mode can be set.

 

● For detail of PRO mode, refer to “ 

PRO MODE OPERATION MANUAL

.”

DOWN (-) key (select)

MODE indicator PRO (Yellow)

MODE key

UP (+) key (select)

SET key (confirm)

Procedure

SET

SET

+, -

+, -

+, -

+, -

+, -

+, -

+, -

+, -

+, -

+, -

+, -

+, -

+, -

+, -

+, -

+, -

+, -

+, -

+, -

+, -

+, -

+, -

+, -

+, -

+, -

+, -

SET

<PRO1>

Shift amount setting

Timer setting

Responce time setting

Hysteresis setting

Emission power setting

Timer range setting

Teaching lock setting

Setting items in digital display setting

Setting of digital display turning

Time period hold setting

Data bank loading setting

Back up setting

Communication protocol setting

Display adjustment setting

Setting of threshold value tracking

Copy lock setting

Copy action setting

Data bank saving setting

<PRO3>

<PRO5>

Code setting

<PRO6>

Reset setting

CUSTOM setting

Interference prevention setting

Sensing output setting

<PRO4>

Copy setting

<PRO2>

ECO setting

SET

SET

SET

+, -

External input setting

SET

<PRO7>

Logic operation setting

+, -

+, -

+, -

+, -

+, -

7

THRESHOLD VALUE FINE ADJUSTMENT FUNCTION

 

● Set fine adjustment of threshold value in RUN mode.

 

● Also, the threshold value fine adjustment function can be used in forced ON 

output mode and forced OFF output mode

 

● For setting of the sensing output, refer to 

<PRO6>

 in “

PRO MODE OPERA-

TION MANUAL

.”

<Normal mode, Rising differential mode or Trailing differential mode>

Confirmed

Press down  

UP / DOWN key

Press down 

SET key

Automatically set without pressing 

down SET key in approx. 2 sec.

<Window comparator mode or Hysteresis mode>

 

● When setting sensing output to the window comparator mode or hysteresis 

mode, “ 

 ” and “ 

 ” can be changed to another by pressing down 

SET key for 2 sec.

In case conducting threshold value fine adjustment of “ 

 ” or “ 

 ”, press 

down UP key or Down key, and “ 

 ” or “ 

 ” are displayed. Then, the 

threshold value fine adjustment can be conducted.

Press down  

UP / DOWN key

Press down 

SET key

Press down

UP / DOWN key

Confirmed

Automatically set without pressing 

down SET key in approx. 2 sec.

Note:  It may not respond when values of “ 

 ” and “ 

 ” are close because of relation of hysteresis. Be sure 

to confirm with this device.

8

KEY LOCK FUNCTION

 

● The key lock function prevents key operations so that the conditions set in 

each setting mode are not inadvertently changed.

 

● If operating key switch after key lock is set, “ 

 

” is indicated on the 

digital display.

<Set key lock>

Automatic

Press down for 

3 sec. or more

<Release key lock>

are displayed

Press down for 

3 sec. or more

Automatic

9

SENSING OUTPUT OPERATION MODE

 

● When MODE indicator: L / D (yellow) lights up, sensing output operation can be set.

Press down 

SET key

Press down 

UP / DOWN key

Confirmed

Confirmed

10

CUSTOM MODE

 

● When MODE indicator: CUST (yellow) lights up, 

Response time setting, Emission power setting 

or Hysteresis setting can be displayed.

For the setting procedure, refer to 

<PRO5>

 in 

PRO MODE OPERATION MANUAL

.”

 

● By pressing UP key or DOWN key, the setting in 

each item will be changed.

MODE indicator

CUST (Yellow)

UP key

SET key

DOWN key

MODE key

 

● Press SET key to confirm the setting.

 

● For setting of each item, refer to the following table.

Item

Digital display

Reference item

Response time setting

<PRO 1: Response time setting>

Emission power setting

<PRO 1: Emission power setting>

Hysteresis setting

<PRO 1: Hysteresis setting>

056 222 38 18

[email protected]

www.sentronic.com

SENTRONIC

AG

Summary of Contents for FX-505P-C2

Page 1: ...or country 1 INTENDED PRODUCTS FOR CE MARKING This product complies with the following standards regulations EU Directive EMC Directive Standards in US Canada ANSI UL 60947 5 2 CAN CSA C22 2 No 14 Regulations in Korea S1 G 1 2009 S2 W 5 2009 Caution about UL recognition In case requiring conformity of UL listing mark or C UL listing mark USe class 2 power supply unit Contact for CE Panasonic Marke...

Page 2: ...the sensing object present condition 3rd time Note If the value after setting exceeds the maximum minimum the maximum minimum sensitivity will be set Span adjustment in rising differential mode or trailing differential mode Move to the rising differential mode or the trailing differential mode in the PRO6 mode and press the jog switch to confirm the setting For the setting procedure refer to PRO6 ...

Page 3: ...can be changed to another by pressing down SET key for 2 sec In case conducting threshold value fine adjustment of or press down UP key or Down key and or are displayed Then the threshold value fine adjustment can be conducted Press down UP DOWN key Press down SET key Press down UP DOWN key Confirmed Automatically set without pressing down SET key in approx 2 sec Note It may not respond when value...

Page 4: ...no loose or clearance between the upper communication unit and amplifiers 15 SPECIFICATIONS Type Cable type NPN output PNP output Model No FX 505 C2 FX 505P C2 Supply voltage 12 to 24V DC Ripple P P10 or less Power consumption Note 1 Normal operation 960mW or less current consumption 40mA or less at 24V supply voltage Eco mode 680mW or less current consumption 28mA or less at 24V supply voltage Se...

Reviews: