1-point teaching [Window comparator mode (except sensing output 2) / Hysteresis mode]

 

● This is method to set the shift amount to the desired value and to set the 

threshold range by using the 1-point teaching.

<Hysteresis mode>

1_SL

P-1

2_SL

<Window comparator mode>

1_SL

P-1

2_SL

Set to de-

sired value

Set to de-

sired value

Set to de-

sired value

Set to de-

sired value

Stable sensing is possible

1.

  Pressing SET key down

2.

  Press the SET key down in the sensing object present condition.

Stable sensing is not possible

3.

  The threshold value (1_SL) that is 10% lower from the incident 

light intensity and the threshold value (2_SL) that is 10% higher 

from the incident light intensity are set. (Note 1, 2)

Notes 1) The shift amount of 10% is an initial value. The shift amount can be set in PRO mode. Furthermore, the shift value 

can be set in incident light amount. For setting method, refer to 

<PRO6>

 in “

PRO MODE OPERATION MANUAL

.”

 

2) If the value after setting exceeds the maximum (minimum), the maximum (minimum) sensitivity will be set.

2-point teaching [Window comparator mode (except sensing output 2) / Hysteresis mode]

 

● This is method to set the threshold range by conducting the 2-point teaching (P-1, P-2).

 

● When conducting teaching, use sensing objects (P-1 and P-2) whose incident 

light intensities are different from each other.

<Hysteresis mode>

1_SL (P-1)

2_SL (P-2)

<Window comparator mode>

1_SL (P-1)

2_SL (P-2)

Stable sensing is possible

1.

  Pressing SET key down (1st time)

2.

  Press down the SET key in the sensing object present condition. 

(2nd time)

Stable sensing is not possible

Note:  If the value after setting exceeds the maximum (minimum), the maximum (minimum) sensitivity will be set.

3-point teaching [Window comparator mode (except sensing output 2) / Hysteresis mode]

 

● This is the method to conduct the 3-point teaching (P-1, P-2, P-3) and to set the 

threshold range by setting the threshold value (1_SL) of the mid-point between “A” 

and “B” and the threshold value (2_SL) of the mid-point between “B” and “C”.

 

● When conducting teaching, use sensing objects (A, B and C) whose incident 

light intensities are different.

 

● After teaching, P-1, P-2 and P-3 will be automatically relocated in ascending order: 

i.e. the lowest value is placed in “A”, the second lowest in “B” and the highest in “C”.

<Hysteresis mode>

A

2_SL

1_SL

B

C

<Window comparator mode>

A

2_SL

1_SL

B

C

Stable sensing is possible

1.

  Press SET key down in the sensing object present condition (1st time)

2.

  Press SET key down in the sensing object present condition (2nd time)

Stable sensing is not possible

3.

  Press SET key down in the sensing object present condition (3rd time)

Note:  If the value after setting exceeds the maximum (minimum), the maximum (minimum) sensitivity will be set.

Span adjustment in rising differential mode or trailing differential mode

 

● Move to the rising differential mode, or the trailing differential mode in the 

PRO6 mode, and press the jog switch to confirm the setting.For the setting 

procedure, refer to 

<PRO6>

 in “

PRO MODE OPERATION MANUAL

.”

 

● The threshold can be set by using the threshold value fine adjustment function. 

For the threshold value fine adjustment function, refer to “

THRESHOLD 

VALUE FINE ADJUSTMENT FUNCTION

Short span

Long span

Changed intensity

6

TEACHING MODE

 

● Be sure that detection may become unstable depending on the use environ-

ment in teaching if less margin is applied.

 

● When teaching in Window comparator mode or Hysteresis mode, a setting 

has to be made in PRO mode beforehand.

In case 1-point teaching, make sure to set the shift amount. (initial value is 

10% or 100)

For the setting, refer to 

<PRO6>

 in “

PRO MODE OPERATION MANUAL

.”

 

● Teaching can be set in RUN mode.

2-point teaching

This is basic teaching method.

<Reflective type>

<Thru-beam type>

1

2

1

2

Stable sensing is possible

1.

  Press the SET key in the sensing object present condition.

2.

  Press the SET key in the sensing object absent condition.

Stable sensing is not possible

Limit-teaching

<Thru-beam type and refractive type are common>

or

Stable sensing is possible

1.

  Press the SET key in the sensing 

object present condition or non 

sensing object present condition.

2.

  The threshold level is shifted 

to high value (low sensitivity) 

by pressing down UP key.

  The threshold level is shifted 

to low value (high sensitivity) 

by pressing down UP key.

Stable sensing is not possible

Note:  The shift value of approx. 15% is an initial value. Display of the shift value can be changed to per-

centage [approx. 0 to 999% (unit 1 %)] or incident light intensity [0 to 9999 (unit 1)].

 

For setting the shift amount, refer to 

<PRO1>

 in “

PRO MODE OPERATION MANUAL

.”

Full-auto teaching

<Thru-beam type and refractive type are common>

Stable sensing is possible

1.

  Pressing SET key down 

2.

  Run the sensing object on the line and hold down the 

SET key.

Stable sensing is not possible

3.

  “ 

 ” is displayed on the digital display (green) and 

when the sensing object passed through, release the 

SET key.

Automatic

Pressing down long

Useful when sensing object can be set 

Useful when sensing object cannot be set

This is teaching method in case small object or object in back 

ground are existing.

This is method to conduct teaching doing sensing object is 

moving.

Useful when not want to stop production line and to keep the sensing object move

056 222 38 18

[email protected]

www.sentronic.com

SENTRONIC

AG

Summary of Contents for FX-505P-C2

Page 1: ...or country 1 INTENDED PRODUCTS FOR CE MARKING This product complies with the following standards regulations EU Directive EMC Directive Standards in US Canada ANSI UL 60947 5 2 CAN CSA C22 2 No 14 Regulations in Korea S1 G 1 2009 S2 W 5 2009 Caution about UL recognition In case requiring conformity of UL listing mark or C UL listing mark USe class 2 power supply unit Contact for CE Panasonic Marke...

Page 2: ...the sensing object present condition 3rd time Note If the value after setting exceeds the maximum minimum the maximum minimum sensitivity will be set Span adjustment in rising differential mode or trailing differential mode Move to the rising differential mode or the trailing differential mode in the PRO6 mode and press the jog switch to confirm the setting For the setting procedure refer to PRO6 ...

Page 3: ...can be changed to another by pressing down SET key for 2 sec In case conducting threshold value fine adjustment of or press down UP key or Down key and or are displayed Then the threshold value fine adjustment can be conducted Press down UP DOWN key Press down SET key Press down UP DOWN key Confirmed Automatically set without pressing down SET key in approx 2 sec Note It may not respond when value...

Page 4: ...no loose or clearance between the upper communication unit and amplifiers 15 SPECIFICATIONS Type Cable type NPN output PNP output Model No FX 505 C2 FX 505P C2 Supply voltage 12 to 24V DC Ripple P P10 or less Power consumption Note 1 Normal operation 960mW or less current consumption 40mA or less at 24V supply voltage Eco mode 680mW or less current consumption 28mA or less at 24V supply voltage Se...

Reviews: