background image

4

I/O CIRCUIT DIAGRAMS

<FX-505-C2>

Load

+
-

12 to 24V DC 

%

Load

Load (0 to 250Ω)

Main circuit

(Brown) +V

(Pink) External input

(Black) Sensing output 1

(White) Sensing output 2

(Blue) 0V
(Gray) Monitor current output (4 to 20mA)

<FX-505P-C2>

Load

+
-

12 to 24V DC 

%

Load

Load (0 to 250Ω)

(Brown) +V

(Pink) External input

(Black) Sensing output 1

(White) Sensing output 2

Main circuit

(Blue) 0V
(Gray) Monitor current output (4 to 20mA)

Note:  Make sure to insulate the ends of the unused lead wires.

5

OPERATION PROCEDURE

 

● The sensing output can be switched to sensing output 1 or sensing output 2 

by holding down the mode key.

 

● The changed settings are not stored if turning the power OFF while setting.

Therefore, confirm the settings by pressing the SET key before turning the

power OFF.

 

● When turning ON the power, RUN mode is displayed and the digital display 

shows the threshold value (green) and the incident light intensity (red).

• Displays threshold value (green) and incident light intensity (red).

• Teaching, threshold value fine adjustment and key lock function

can be set.

• For setting method of each function, refer to “

TEACHING 

MODE

,” “

THRESHOLD VALUE FINE ADJUSTMENT FUNC-

TION

,” or “

KEY LOCK FUNCTION

.”

• Select either Light-ON or Dark-ON.

• For the setting, refer to “

SENSING OUTPUT OPERATION

MODE

.”

• The default setting is “ 

 ” (Light-ON).

• An item set in CUSTOM mode (Response time setting, Emission 

power setting and Hysteresis setting) is displayed.

• For details, refer to “

CUSTOM MODE

.”

• The default setting is “ 

 ” (response time setting).

• Advanced setting can be done.

• For the setting, refer to “

PRO MODE

.”

<RUN mode>

<Sensing output operation mode>

<CUSTOM mode>

<PRO mode>

<RUN mode>

INSTRUCTION MANUAL

Digital Fiber Sensor Amplifier 

FX-505

-C2

MJE-FX505C2C No.0052-96V

Thank you very much for purchasing Panasonic products.

Please read this Instruction Manual carefully and thoroughly for the correct and 

optimum use of this product.

Kindly keep this manual in a convenient place for quick reference.

WARNING

 

● Never use this product as a sensing device for personnel protection.

 

● In case of using sensing devices for personnel protection, use products which 

meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel

protection applicable in each region or country.

1

INTENDED PRODUCTS FOR CE MARKING

● This product complies with the following standards / regulations.

<EU Directive>

EMC Directive 

<Standards in US / Canada>

ANSI/UL 60947-5-2, CAN/CSA C22.2 No.14

<Regulations in Korea>

S1-G-1-2009, S2-W-5-2009

Caution about UL recognition

In case requiring conformity of UL listing mark or C-UL listing mark, USe class 

2 power supply unit.

 

Contact  for CE

Panasonic Marketing Europe GmbH Panasonic Testing Center

Winsbergring 15, 22525 Hamburg,Germany

2

PART DESCRIPTION

Digital display

(Green / Red)

UP key

• Teaching

• Threshold  value

fine adjustment

•  Select setting items

MODE key

• Select Modes

• Cancel during setting

• Select sensing output 1/2

by pressing long

SET key

• Teaching

• Confirm  setting

contents

DOWN key

• Teaching

• Threshold value fine

adjustment

• Select setting items 

Sensing output 2 

selection indicator 

(Yellow) 
Sensing output 1

selection indicator 

(Yellow)

Sensing output 1 

operation indicator 

(Orange)

Sensing output 2 

operation indicator 

(Orange)

MODE indicator: PRO (Yellow)

MODE indicator: L / D (Yellow)

MODE indicator: CUST (Yellow)

Pressing down SET key + MODE key for 3 sec : Set key lock or Release key lock

3

MOUNTING

How to connect

1.

Fit the rear part of the mounting sec-

tion of the amplifier on a DIN rail.

2.

Press  down  the  rear  part  of  the

mounting section of the unit on the

DIN rail and fit the front part of the

mounting section to the DIN rail.

How to remove

1.

Push the controller forward.

2.

Lift up the front part of the amplifier

to remove it.

2. 

Lift up

1. 

Push forward

2. 

Press down

1. 

Fit

35mm width DIN rail

How to connect the fiber cable

Be sure to fit the attachment to the fibers first before inserting the fibers to the 

amplifier. For details, refer to the instruction manual enclosed with the fibers.

1.

Snap the fiber lock lever down till it

stops completely.

2.

  Insert the fiber cables slowly into the 

inlets until they stops. (Note)

3.

Return  the  fiber  lock  lever  to  the

original position till it stops.

Fiber lock lever

Fiber for 

receiver

1. 

Snap

3. 

Return

2. 

Insert

Fiber for emitter

Note:  With the coaxial reflective type fiber, such as , 

FD-G4

 or 

FD-FM2

, insert the single core fiber cable into the 

beam-emitting inlet “P” and the multi-core fiber cable into the beam-receiving inlet.

If they are inserted in reverse, the sensing performance will deteriorate.

<Reference>

056 222 38 18

[email protected]

www.sentronic.com

SENTRONIC

AG

Summary of Contents for FX-505P-C2

Page 1: ...or country 1 INTENDED PRODUCTS FOR CE MARKING This product complies with the following standards regulations EU Directive EMC Directive Standards in US Canada ANSI UL 60947 5 2 CAN CSA C22 2 No 14 Regulations in Korea S1 G 1 2009 S2 W 5 2009 Caution about UL recognition In case requiring conformity of UL listing mark or C UL listing mark USe class 2 power supply unit Contact for CE Panasonic Marke...

Page 2: ...the sensing object present condition 3rd time Note If the value after setting exceeds the maximum minimum the maximum minimum sensitivity will be set Span adjustment in rising differential mode or trailing differential mode Move to the rising differential mode or the trailing differential mode in the PRO6 mode and press the jog switch to confirm the setting For the setting procedure refer to PRO6 ...

Page 3: ...can be changed to another by pressing down SET key for 2 sec In case conducting threshold value fine adjustment of or press down UP key or Down key and or are displayed Then the threshold value fine adjustment can be conducted Press down UP DOWN key Press down SET key Press down UP DOWN key Confirmed Automatically set without pressing down SET key in approx 2 sec Note It may not respond when value...

Page 4: ...no loose or clearance between the upper communication unit and amplifiers 15 SPECIFICATIONS Type Cable type NPN output PNP output Model No FX 505 C2 FX 505P C2 Supply voltage 12 to 24V DC Ripple P P10 or less Power consumption Note 1 Normal operation 960mW or less current consumption 40mA or less at 24V supply voltage Eco mode 680mW or less current consumption 28mA or less at 24V supply voltage Se...

Reviews: