background image

1

n

MEUML-FX301 V1.1

Thank you for purchasing products from Panasonic Electric Works SUNX
Co., Ltd. Please read this Instruction Manual carefully and thoroughly for
the correct and optimum use of this product. Kindly keep this manual in a
convenient place for quick reference.

1

For further details on the fiber sensor amplifier, please refer to our 
Web site: 

www.panasonic-electric-works.com

, or contact our office.

This product has been developed / produced for industrial use only.

Make sure to carry out wiring with the power OFF.

Verify that the supply voltage including the ripple is within the rating.

Do not connect the sensor to voltage that exceeds the rated range or
directly to an AC power supply: it may damage or burn the sensor.

Incorrect wiring or short-circuiting the load may damage or burn the
sensor.

When the emitting level function is turned from OFF to ON for any level,
the output may be unstable. Do not use the output control for at least
0.5s after starting emission. (See “PRO1” on page 6.)

If power is supplied from a commercial switching regulator, ensure that
the frame ground (F.G.) terminal of the power supply is connected to an
actual ground.

In case noise generating equipment (switching regulator, inverter motor,
etc.) is used in the vicinity of this product, connect the frame ground
(F.G.) terminal of the equipment to an actual ground.

Do not run the wires together with high-voltage lines or power lines or put
them in the same raceway. This can cause malfunction due to induction.

Do not use during the initial transient time (0.5s) after the power supply is
switched on.

This sensor is suitable for indoor use only.

You can extend the cable up to 100m max. with 0.3mm

2

 or more cable. If

5 to 8 units are connected in cascade, the limit is 50m; for 9 to 16 units in
cascade, 20m. However, in order to reduce noise, make the wiring as
short as possible.

Note that extending the cable increases the residual voltage.

Be sure to use the optional quick-connection cable when connecting to
the connector type sensor FX-301(P).

Avoid dust, dirt and steam.

Take care that the sensor does not come in contact with oil, grease,
organic solvents such as thinner, etc., strong acid, or alkaline.

Do not use this sensor in an environment containing inflammable or
explosive gases.

Never disassemble or modify the sensor.

 

You may break the spring hook if you do not follow the mounting 

instructions carefully.

How to mount the amplifier

How to remove the amplifier

INSTRUCTION MANUAL

Photoelectric Sensor

Digital Fiber Sensor

FX-301 

Series

1

The digital fiber sensor FX-301(P) has been modified since production in June, 

2004. Hence, this instruction manual has been changed to reflect the modifica-
tions.

WARNING

• Never use this product as a sensing device for personnel protection.
• In case of using sensing devices for personnel protection, use 

products which meet laws and standards, such as OSHA, ANSI or IEC 
etc., for personnel protection applicable in each region or country.

1

CAUTIONS

2

PART DESCRIPTION

No.

Part

Description

Q

Operation indicator 
(orange)

Lit when output is on.

W

Stability indicator 
(green)

Lit when detection is stable according 
to the parameters set.

E

RUN mode indica-
tor (green)

Lit when FX-301 is in RUN mode.

R

TEACH mode indi-
cator (yellow)

Lit when FX-301 is in TEACH mode.

T

ADJ mode indicator 
(yellow)

Lit when FX-301 is in ADJ (threshold 
value adjustment) mode.

Y

Digital display (red)

Displays incident light intensity under 
normal circumstances. Also displays 
sub-modes and settings.

U

L/D mode indicator 
(yellow)

Lit when FX-301 is in L/D mode (Light-
ON, Dark-ON) mode.

I

TIMER mode indica-
tor (yellow)

Lit when FX-301 is in TIMER mode.

O

PRO mode indica-
tor (yellow)

Lit when FX-301 is in PRO mode.

P

Jog switch

The jog switch allows you to select the 
various sub-modes and confirm set-
tings.

{

Mode key

The mode key allows you to switch 
from mode to mode, or to cancel set-
tings and return to RUN mode.

3

MOUNTING

1

Fit the spring hook on a 35mm DIN rail and
push forward.

2

Slip the front part of the mounting section over
the DIN rail and release.

1

Push the amplifier forward

2

Lift up the front part of the amplifier.

RUN

TEACH

ADJ

MODE

CANCEL

PUSH

TIMER

W E

O

I

Y U

T

R

P

Q

{

Ԙ

ԙ

35mm

1

2

Summary of Contents for FX-301 Series

Page 1: ... to the connector type sensor FX 301 P Avoid dust dirt and steam Take care that the sensor does not come in contact with oil grease organic solvents such as thinner etc strong acid or alkaline Do not use this sensor in an environment containing inflammable or explosive gases Never disassemble or modify the sensor You may break the spring hook if you do not follow the mounting instructions carefull...

Page 2: ...tional version units as viewed from the connector side For details see page 8 section 16 UNIT VERSIONS Only the interference prevention function can be transmitted between this product and other digital fiber amplifiers Therefore mount identical models together when mounting in cascade Please note the interference prevention function is not incorporated in the FX 301 P HS Be careful when the senso...

Page 3: ...UIT DIAGRAMS Symbol Meaning D Reverse supply polarity protection diode ZD Surge absorption zener diode Tr1 NPN output transistor Tr2 PNP output transistor 8 OPERATION PROCEDURE MODE key Jog switch Press Press Turn side side V 0V 1 3 2 Output D1 1 2 3 Tr1 ZD1 10 12 to 24V DC Internal circuit Users circuit Brown V note Load Black Output Sensor circuit 100 mA max note Blue 0V note Color of core wire ...

Page 4: ...ty and the TEACH mode indicator blinks 3 Turn the jog switch to the side or the side to set the shift for the threshold value 1 A comma scrolls from right to left across the display twice 4 The judgement for the sensing stability is displayed briefly sensing stable stable sensing not possible 5 The threshold value is displayed briefly 6 The actual incident light intensity is displayed and the sett...

Page 5: ...ription 1 Press MODE briefly and repeatedly until the ADJ operation indicator is lit 2 Turn the jog switch to the side to increase the threshold value i e decrease sensitivity or to the side to lower the threshold value i e increase sen sitivity 3 Press the jog switch briefly to confirm the setting 11 OUTPUT OPERATION MODE Step Description 1 Press MODE briefly and repeatedly until the L D operatio...

Page 6: ...nts of 5 Reflective type fiber If the threshold value is shifted toward the direction minute detections are possible Thru beam type fiber If the threshold value is shifted toward the direction minute detections are possible 4 Level 4 Highest emitting power Level 3 Level 2 Level 1 Lowest emitting power Emission halt While in RUN mode is displayed when the emission halt state is valid 1 The S d sett...

Page 7: ...tings remotely 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 When copying data from the 4th unit it will be copied to units 5 and up but not to units 1 3 Direction of communication When copying data from the 1st unit it will be copied to all sub units Back up ON Back up OFF Prevents frequent overwriting of data in the EEPROM the threshold values are not stored in the EEPROM when teaching via external inp...

Page 8: ...s the original version Modified unit Conventional unit When mounting the modified version units and conventional version units together in cascade place the modified version units on the right of the conventional version units as viewed from the connector side 14 KEY LOCK FUNCTION 15 ERROR INDICATION Display Error Description Measures The load is short cir cuited causing overcur rent Turn off the ...

Page 9: ...ess STD 250μs or less LONG 2ms or less Display 4 digit red LED display Sensitivity setting 2 point teaching limit teaching full auto teaching manual adjustment Sensitivity adjustment function 3 3See THRESHOLD VALUE ADJUSTMENT MODE on page 5 Incorporated Timer function Incorporated Available modes off ON delay OFF delay ONE SHOT timer Timer interval range approx 0 5 to 9999ms Interference preventio...

Reviews: