Press the jog switch to confirm settings.

5

Press <MODE> briefly at any time to move up one level. Press <MODE>
for 2s to return to RUN mode.

PRO1

PRO2

PRO2 mode is used to control the display.

Mode

Setting

Description

Ultra high speed

Response time 65

μ

s or less.

Fast

Response time 150

μ

s or less.

Reduced inten-
sity

*1

Response time 250

μ

s or less.

Standard

Response time 250

μ

s or less.

Long-range

Response time 2ms or less.

No timer

_

OFF-delay timer

*2

Extends the output signal for a fixed 
period of time.
This function is useful if the output 
signal is so short that the connected 
device cannot respond.

ON-delay timer

*2

Neglects short output signals. 
This function is useful for detection if 
a line is clogged, or for sensing only 
objects that take a long time to travel.

One-shot timer

*2

Outputs a fixed width signal upon 
sensing.
This function is useful when the input 
specifications of the connected 
device require a signal of fixed width.

Small.
The optimal limit of detection range.

Standard

Large.
Capable of detecting objects that 
vibrate.

Margin width ±5%

*3

The margin is the smallest, hence the 
range in which the stability indicator 
will light up is largest.

Margin width ±10%
Factor setting. Medium range.

Margin width ±15%
The margin is the largest, hence the 
range in which the stability indicator 
will light up is smallest.

(Factory setting.)

For limit teaching (+, -), you can shift, 
i.e. offset, the theshold value by 0 to 
80% in increments of 5%.

Reflective type fiber

. If the 

threshold value is shifted toward 
the “-” direction, minute detections 
are possible.

Thru-beam type fiber

. If the 

threshold value is shifted toward 
the “+” direction, minute detections 
are possible.

*4

Level 4. Highest emitting power.

Level 3.

Level 2.

Level 1. Lowest emitting power.

Emission halt.
While in RUN mode, 

 is displayed 

when the emission halt state is valid.

*1

The S-d setting is suitable for delicate sensing, such as when the received 

light is saturated due to an insufficient sensing distance or when detecting 
translucent objects, etc.

*2

The range starts at 0.5ms, and then proceeds from 1 to 9999ms in 1ms 

intervals.

*3

*4

The levels that can be selected vary depending on the response time.

Mode

Setting

Description

The incident light intensity is displayed.

Percent above threshold value.
This function displays the incident light inten-
sity within a range of 1P (1%) to 999P 
(999%) using the threshold value as refer-
ence.

Peak hold display.
This function displays the peak numerical 
value of the incident light intensity. It is 
refreshed continuously.

Bottom hold display.
This function displays the bottom numerical 
value of the incident light intensity. It is 
refreshed continuously.

The direction of the digital display is normal.

The direction of the digital display is inverted.

ECO mode is OFF.

ECO mode is ON.

When ECO mode is ON, the display turns off after 
20s in RUN mode. To reactivate the display, press 
any key for 2s.

Mode

Setting

Description

0

4,000

Output operation

Stability indicator, ON/OFF

Margin

Threshold 

value

Incident light 

intensity

Light 

received

Light 

interrupted

ON

OFF

ON

Margin

Summary of Contents for FX-301 Series

Page 1: ... to the connector type sensor FX 301 P Avoid dust dirt and steam Take care that the sensor does not come in contact with oil grease organic solvents such as thinner etc strong acid or alkaline Do not use this sensor in an environment containing inflammable or explosive gases Never disassemble or modify the sensor You may break the spring hook if you do not follow the mounting instructions carefull...

Page 2: ...tional version units as viewed from the connector side For details see page 8 section 16 UNIT VERSIONS Only the interference prevention function can be transmitted between this product and other digital fiber amplifiers Therefore mount identical models together when mounting in cascade Please note the interference prevention function is not incorporated in the FX 301 P HS Be careful when the senso...

Page 3: ...UIT DIAGRAMS Symbol Meaning D Reverse supply polarity protection diode ZD Surge absorption zener diode Tr1 NPN output transistor Tr2 PNP output transistor 8 OPERATION PROCEDURE MODE key Jog switch Press Press Turn side side V 0V 1 3 2 Output D1 1 2 3 Tr1 ZD1 10 12 to 24V DC Internal circuit Users circuit Brown V note Load Black Output Sensor circuit 100 mA max note Blue 0V note Color of core wire ...

Page 4: ...ty and the TEACH mode indicator blinks 3 Turn the jog switch to the side or the side to set the shift for the threshold value 1 A comma scrolls from right to left across the display twice 4 The judgement for the sensing stability is displayed briefly sensing stable stable sensing not possible 5 The threshold value is displayed briefly 6 The actual incident light intensity is displayed and the sett...

Page 5: ...ription 1 Press MODE briefly and repeatedly until the ADJ operation indicator is lit 2 Turn the jog switch to the side to increase the threshold value i e decrease sensitivity or to the side to lower the threshold value i e increase sen sitivity 3 Press the jog switch briefly to confirm the setting 11 OUTPUT OPERATION MODE Step Description 1 Press MODE briefly and repeatedly until the L D operatio...

Page 6: ...nts of 5 Reflective type fiber If the threshold value is shifted toward the direction minute detections are possible Thru beam type fiber If the threshold value is shifted toward the direction minute detections are possible 4 Level 4 Highest emitting power Level 3 Level 2 Level 1 Lowest emitting power Emission halt While in RUN mode is displayed when the emission halt state is valid 1 The S d sett...

Page 7: ...tings remotely 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 When copying data from the 4th unit it will be copied to units 5 and up but not to units 1 3 Direction of communication When copying data from the 1st unit it will be copied to all sub units Back up ON Back up OFF Prevents frequent overwriting of data in the EEPROM the threshold values are not stored in the EEPROM when teaching via external inp...

Page 8: ...s the original version Modified unit Conventional unit When mounting the modified version units and conventional version units together in cascade place the modified version units on the right of the conventional version units as viewed from the connector side 14 KEY LOCK FUNCTION 15 ERROR INDICATION Display Error Description Measures The load is short cir cuited causing overcur rent Turn off the ...

Page 9: ...ess STD 250μs or less LONG 2ms or less Display 4 digit red LED display Sensitivity setting 2 point teaching limit teaching full auto teaching manual adjustment Sensitivity adjustment function 3 3See THRESHOLD VALUE ADJUSTMENT MODE on page 5 Incorporated Timer function Incorporated Available modes off ON delay OFF delay ONE SHOT timer Timer interval range approx 0 5 to 9999ms Interference preventio...

Reviews: