The Panasonic Energy Recovery Ventilator (ERV) uses 2 blower fans driven by 2 DC motors.
The motor is designed to have an extended service life with reduced energy consumption.
It also incorporates a thermal-cutoff for safety.
The exhaust air (EA) duct includes an electric damper to prevent backdrafting. The outside
air (OA) duct includes an electric damper to prevent backdrafting.
Energy Recovery Introduction: Compared to an HRV (Heat Recovery Ventilator), the ERV can
also transfer humidity and recover energy from that humidity. The ERV can exchange energy
between the stale EA and the “fresh” OA, transferring heat and moisture into the incoming
cold air in a heating climate and pre-cooling and reducing the humidity of the incoming hot
air in a cooling climate. This tempering and treatment of the required ventilation air helps
maintain a fresh environment even when the heating or cooling system is not operating.
1
4
1
Wall bracket
<Heating Climate>
Part name
Appearance
Quantity
Unpack and remove unit carefully from carton.
Refer to the supplied accessories list to verify that all parts are presented.
<Cooling Climate>
Heat&
Moisture
Fresh air
Fresh air
Exhaust air
(EA)
Outside air
(OA)
Exhaust air
(EA)
Outside air
(OA)
Stale air
Indoor
Stale air
Indoor
Outdoor
Outdoor
Hanger
Hanger
L plate
Installation and
operating instructions
Limited warranty
Plug cover
Screw
(M4X8)
Long screw
(ST4.2X20)
4
4
1
1
12
12
4
DESCRIPTION
SUPPLIED ACCESSORIES
UNPACKING
Heat&