Dimensions continued
3
Specifications
* At 0.0" Static pressure, (Pa)
Unpacking
Unpack and carefully remove unit from carton. Refer to the Supplied components list to verify that all parts are
present.
General safety information
Do not install this ventilating fan/light combination in ducts where air temperature may exceed 104 F. (40 C)
Make certain that the electric service supply voltage is 120V 60Hz.
Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupation
Safety and Health Act (OSHA).
Always disconnect the power source before working on or near the fan, motor or light fixture.
1.
2.
3.
4.
Grille
Junction box
Junction box cover
Body
Damper
Night lamp connector
13W lamp connector
1
3
4
5
6
8
9
Motor connector
7
15
Lamp cover
16
Night lamp
17
Bracket cover
Adapter
2
14
Fluorescent lamp (13W x 2)
10
13
Light unit
12
Thumb screw
(4W x 1)
Model
Air direction
V
Hz
Power consumption* (W)
Fan unit
Light unit
Speed*
(RPM)
Air deliver at 0.1"WG
(CFM)
Weight
lb.(kg)
17.4
(7.9)
70
90
110
725
875
995
26
26
26
18
20
26
60
120
Exhaust
FV-07VQL3
FV-08VQL3
FV-11VQL3
4
4
4
No.
Part name
No.
Part name
11
Installation bracket ,
* **
Installation bracket
*
,
*
Fluorescent lamp
Night lamp
105(4 1/4")
1
14
16
7
8
9
13
12
2
4
268 (10 5/8" )
330 (13" )
228 (9" )