Panasonic FV-08VQL3 Installation Instructions Manual Download Page 1

Ventilating Fan/Light Combination

FV-07VQL3
FV-08VQL3
FV-11VQL3

INSTALLATION

INSTRUCTIONS

READ  AND  SAVE  THESE  INSTRUCTIONS

Please read instructions carefully before attempting to install, operate or service the
Panasonic Ventilating Fan/Light Combination. Failure to comply with instructions could
result in personal injury and/or property damage. Please retain this booklet for future
reference.

Table of Contents

List of components
Description
Dimensions
Specifications
Unpacking
General safety Information
Installation 

I

 (Joist mounting Installation)

Installation 

II

 (Wooden header Installation)

Installation 

III

 (Between joist mounting Installation)

Installation 

IV

 (ln existing construction)

Maintenance 

I (

Replacement of fluorescent lamp or night lamp)

Maintenance 

II

 (Cleaning)

Product Service

2
2

2-3

3
3

3-4
5-8

9

10-13

14
14
15
16

Pages

Summary of Contents for FV-08VQL3

Page 1: ...injury and or property damage Please retain this booklet for future reference Table of Contents List of components Description Dimensions Specifications Unpacking General safety Information Installati...

Page 2: ...produces almost the same illumination as a standard 100W incandescent lamp 2 FV 07VQL3 FV 08VQL3 FV 11VQL3 Unit mm inch FV 07VQL3 FV 08VQL3 FV 11VQL3 Grille Long screw M4 x 30 1 10 2 1 1 1 1 2 1 2 2...

Page 3: ...t OSHA Always disconnect the power source before working on or near the fan motor or light fixture 1 2 3 4 Grille Junction box Junction box cover Body Damper Night lamp connector 13W lamp connector 1...

Page 4: ...nstruction Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s...

Page 5: ...e sure the adapter is level and square perpendicular with the joists Keep the distance B 21 6mm 0 85 inch for the thickness of ceiling board Fig 2 Fig 3 I CAUTION Remove the bracket cover by loosening...

Page 6: ...otor Capacitor Black White Green Green Ballast Light unit Lamp Lamp Power supply AC 120V 60 Hz Earth ground Junction box Ballast WARNING Make all electrical connections in accordance with the National...

Page 7: ...eiling Mount blower section and fix with 3 screws IMPORTANT Make sure that frame is properly inserted into groove of blower section Secure fan body to adapter using two thumb screws 8 7 Fig 6 1 Fig 6...

Page 8: ...nt lamps and screw the night lamp into the light unit Fig 10 11 12 Insert the lamp cover to the grille and attach the grille to the fan unit Fig 11 13 Fix fan body to ceiling joists using long screws...

Page 9: ...the Grille and attach the grille to the fan unit Fig 12 Fig 13 Fig 14 Fig 3 Fig 15 Fig 11 1 Mount junction box cover carefully so that lead wires are not caught CAUTION Junction box cover Circular du...

Page 10: ...an body by using two thumb screws 2 Insert the installation bracket III into slot of the adapter side III Fig 16 Fig 17 Fig 18 installation bracket I installation bracket IV Frame Fig 16 3 Insert the...

Page 11: ...the fan body to ceiling joists using long screws M4X30 in horizontal direction with installation bracket I and IV III CAUTION Fig 21 Fig 20 Fig 19 Joist spacing A should be between 350mm 13 7 8 and 43...

Page 12: ...unction box cover and secure conduit to junction box knockout hole 7 8 inch Refer to wiring diagram on page 6 Using wire nuts connect house power wires to ventilating fan wires Black to blacks white t...

Page 13: ...case Light unit Spacer Long screws Receptacle II Plug connector III Plug connector II Receptacle III Fig 27 Night lamp Spacer Insert the fluoresceut lamps and screw the night lamp into the light unit...

Page 14: ...Squeeze mounting spring and pull down Fig 28 Gloves Fig 29 Connector III Connector II Fig 30 Change the fluorescent bulbs Panasonic FDS 13E 27 U 2 13W or FQ13E 41 U 2 13W or FQ13E 35 U 2 13W orthe4Wi...

Page 15: ...parts to temperature over 140 F 60 C Remove grille Squeeze mounting spring and pull down Wash and clean grille Use non abrasive kitchen detergent Remove dust and dirt from fan body using a vacuum clea...

Page 16: ...actured to ensure a minimum of maintenance However should your unit ever require service a nationwide system of factory service centers and AUTHORIZED INDEPENDENT SERVICE CENTERS is maintained to supp...

Reviews: