INSTALLATION (NEW CONSTRUCTION) CONTINUED

Fig.10

Grille

Ceiling

Gloves

Mounting spring

12. Insert the other mounting spring into the slot as

      shown and mount grille to fan body. (Fig.10)

11. Adjust Pick-A-Flow switch.(Refer to indication on

  FEATURE.)

Mount grille carefully so that lead wire is not

pinched.

CAUTION

Attention: when the switch is at the “ON” position, wait 8 – 10  

seconds for the Fan to start.  This is a normal working condition.    

INSTALLATION (RETROFIT)

Ceiling

Flange

Machine screw (M4X8)

2 Self-drilling screws (Fix the 

TM

flange and Flex-Z Fast

through the ceiling)

 bracket 

1. Remove the existing fan and cut ceiling opening.

Secure the Flex-Z Fast     bracket to joists 

    by drilling 4 tapping screws (ST4.2x20) which 

    have been fixed on it. Existing ductwork and 

    wiring left in place. (Fig.11) 
2. Follow the step 1 , 4 , 5 , 7 on INSTALLATION

    (NEW CONSTRUCTION). (Before connect the

    circular duct to the adaptor, should pull down 

    the circular duct from the ceiling)

Disconnect power source before working 

on unit.

5. Follow the step 10 to 12 on INSTALLATION

    (NEW CONSTRUCTION)

TM

TM

3. Install the adaptor to Flex-Z Fast     bracket by 

    using 2 self-drilling screws. (Fig.12)
4. Secure the fan body to Flex-Z Fast     bracket by 

    using 2 self-drilling screws, plug connector to

    receptacle and secure the fan body to adaptor

    by using machine screw (M4X8). (Fig.13)

Secure machine screw (M4X8) to the suitable 

hole and not touch the Flex-Z Fast     bracket. 

Please fix the screw carefully to avoid screw 

slip teeth.

TM

Fig.13

CAUTION

WARNING

10 7/8 

(275)

10 7/8 (275)

Circular duct

Conduit

Joist

4Tapping

(ST4.2x20)

Unit: inches (mm)

Fig.11

Ceiling (already existed)

screws

Mastic or 

approved

foil tape

2 Self-drilling screws

Ceiling

Joist

Knock-out

hole

Junction box

cover

Conduit Circular duct

Fig.12

Joist

TM

English

Summary of Contents for FV-0511VKL2

Page 1: ...L2 Representative models 2 3 3 4 4 5 5 5 5 6 6 7 7 8 8 10 10 11 READ AND SAVE THESE INSTRUCTIONS Thank you for purchasing this Panasonic product Please read these instructions carefully before attempting to install operate or service the Panasonic product Please carefully read the GENERAL SAFETY INFORMATION Failure to comply with instructions could result in personal injury or property damage Plea...

Page 2: ...contact the manufacturer Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Installation work and electrical wiring must be done by qualified person s in acc...

Page 3: ...eed control device Solid state controls may cause harmonic distortion which can cause motor humming noise Follow all local electrical and safety codes as well as the National Electrical Code NEC and the Occupation Safety and Health Act OSHA Always disconnect the power source before working on or near the fan motor or junction box Protect the supply wiring from sharp edges oil grease hot surfaces c...

Page 4: ...ty sirocco fan developed to reduce the noise level The FCC Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not insta...

Page 5: ...5VKL2 10 1 4 260 5 7 8 151 5 7 8 148 13 330 7 1 2 190 1 1 4 30 4 1 2 114 1 1 2 37 3 7 8 100 12 304 3 3 8 86 13 1 4 15 1 2 336 394 16 1 2 18 3 4 419 480 21 1 4 23 1 2 540 597 3 3 8 86 6 5 8 169 10 1 4 261 13 330 3 7 8 100 3 7 8 100 1 8 3 4 5 2 FV 0511VKL2 FV 1115VKL2 Part name Blade Grille Part name No No 8 2 4 1 3 5 6 10 12 11 Motion sensor location FV MSVK1 not included Multi Speed module FV 0511...

Page 6: ... the selected amount of time before returning to the lower speed setting chosen on the CFM dial Pick A Flow CFM Multi Speed Air volume CFM 50 110 110 130 150 0 0 0 0 0 0 40 40 40 60 60 60 40 60 60 80 80 80 40 70 80 100 100 100 40 70 80 100 100 110 120 30 30 30 50 50 50 40 50 50 70 70 70 40 70 70 90 90 90 40 70 90 100 110 110 Factory setting 20 minutes Delay Time position 0 Manual wall switch contr...

Page 7: ...FV VS15VK1 Fan Hi Low speed Depend on FV VS15VK1 Time delay setting FV MSVK1 FV VS15VK1 FV MSVK1 Motion Sensor module turns the base fan on or boosts to higher speed when motion is detected when using in combination with the FV VS15VK1 The Motion Sensor is pre set to run for 20 minutes it will then re check for movement if detected the fan will run for another 20 minutes cycle The Motion Sensor de...

Page 8: ...ast bracket to joists by drilling 2 tapping screws which have been fixed on it Fig 2 TM TM 3 Adjust the length of Flex Z Fast bracket as the spacing between joists and install to joists by drilling the other 2 tapping screws which have been fixed on it Fig 3 4 Remove junction box cover and secure conduit or stress relief to junction box knock out hole Fig 4 TM 6 Install the adaptor to Flex Z Fast ...

Page 9: ...Secure machine screw M4X8 to the suitable hole and not touch the Flex Z Fast bracket Please fix the screw carefully to avoid screw slip teeth TM 9 Finish ceiling work Ceiling hole should be aligned with the inside edge of the flange Fig 7 CAUTION CAUTION 10 Insert the grille mounting spring on the wiring side into the slot and insert the plug connector into the housing of the lighting unit Fig 8 B...

Page 10: ...g 11 2 Follow the step 1 4 5 7 on INSTALLATION NEW CONSTRUCTION Before connect the circular duct to the adaptor should pull down the circular duct from the ceiling Disconnect power source before working on unit 5 Follow the step 10 to 12 on INSTALLATION NEW CONSTRUCTION TM TM 3 Install the adaptor to Flex Z Fast bracket by using 2 self drilling screws Fig 12 4 Secure the fan body to Flex Z Fast br...

Page 11: ...t into hot water Use non abrasive kitchen detergent wipe dry with clean cloth Fig 16 3 The grille should be dry after cleaning 4 Remove dust and dirt from fan body using a vacuum cleaner Fig 17 5 Using a cloth dampened with kitchen detergent remove any dirt from fan body Wipe dry with clean cloth Fig 18 6 Reinstall grille 1 Remove grille by pulling down one mounting spring Fig 14 then pull down th...

Page 12: ...ment and absorbs sound Clamps plus mastic or approved foil faced tape at all flex joints Foil tape tightly covers all metal duct joints glue PVC joints Properly insulate the area around the fan to minimize building heat loss and gain Fig 19 Loose fill or batt insulation can be placed directly over the fan housing in the attic Our fans does not create excessive heat that is a common problem with re...

Reviews: