10

TEACHING FUNCTION

 

●  In this function, sets the threshold value of the comparative output 1 based on the 

instantaneous flow rate value at the time of key operation or inputting external sig-

nal. For setting the teaching function, refer to “

CH2 setting

” in “

9

PRO MODE

.”

OFF

<1-point input, ON when higher than threshold value>

Threshold value

Threshold value

Threshold value

Input value 1 Input value 2

Threshold value 1 Threshold value 2

Threshold value 1 Threshold value 2

Input value 1 Input value 2

Threshold value

ON

OFF

<1-point input, ON when lower than threshold value>

ON

OFF

<2-point input, ON when higher than threshold value>

(Input value 1 + Input value 2) /2 = Threshold value

(Input value 1 + Input value 2) /2 = Threshold value

ON

OFF

<2-point input, ON when lower than threshold value>

ON

OFF

<2-point input, ON when within the 2 points>

ON

OFF

<2-point input, ON when out of the 2 points>

ON

Comparative

output

Comparative

output

Comparative

output

Comparative

output

Comparative

output

Comparative

output

Flow rate

Flow rate

Flow rate

Flow rate

Flow rate

Flow rate

Note: The hysteresis of approx. 1% F.S. (factory setting) is set to the smaller threshold value side. The hysteresis can 

be changed in the range of approx. 1 to 8% F.S. For details, refer to “

Hysteresis setting

” in “

9

PRO MODE

.”

[How to load the reference instantaneous flow rate value]

In case of key operation

(RUN mode)

(Display of loading value) 

(RUN mode)

Hold down for 2 sec.

/

Automatic

Automatic

In case of 1-point input:  Hold down DOWN key for 2 sec. to load instantaneous flow 

rate value and set threshold value.

In case of 2-point input: Hold down UP key and DOWN key for 2 sec. to load the in-

put values of 2 points. The threshold value is set automati-

cally by discriminating the magnitude relation of the input 

values between 2 points. 

In case of external input

CH2

ON for 80ms

(RUN mode)

(Display of loading value) 

(RUN mode)

Automatic

Automatic

In case of 1-point input: Turn ON the external input for 80ms to load instantaneous 

flow rate value and set threshold value. 

In case of 2-point input:  Turn ON the external input for 80ms to load the first input val-

ue. When turning ON the external input again for 80ms, loads 

the second input value. The threshold value is set automatical-

ly by discriminating the magnitude relation between the first 

point and the second point. When inputting the third point and 

the fourth point successively, the latest input value will be valid 

and the threshold value is set. The default loading value is 0.

Notes: 1) The threshold value set at the teaching function will be reset when turning ON the power again.

 

2) Loads the instantaneous flow rate value to the comparative output 1 by teaching. 

 

  After the load is complete, ON / OFF pulses (approx. 40ms) are outputted after approx. 6 sec. at 1-point in-

put, approx. 10 sec. at 2-point input.

11

ERROR INDICATION

Error indication

Cause

Remedy

Fluid flows during zero-point adjustment.

Make sure to check that fluid does not flow and  

conduct zero-point adjustment again.

Internal process error

Turn ON the power supply again. If not restoring 

normally, contact Panasonic Industrial Devices 

SUNX.

Flow rate is exceeding upper limit of the 

display range.

The instantaneous flow rate should be brought 

within the display flow rate range.

Flow rate is exceeding lower limit of the 

display range.

Operation indicator 

is blinking

Load is short-circuited causing an over-

current to flow.

Turn OFF the power and check the load.

12

CAUTIONS

 

●  This product has been developed / produced for industrial use only.

 

● This product is for use in air and nitrogen only. Do not use the product for other 

fluids since the sensing accuracy cannot be guaranteed.

 

●  Take care that if foreign materials are mixed in the sensing part, the product may break.

 

● Do not use this product for commercial purposes since the product does not com-

ply with International System of Units (SI).

 

● Do not apply pressure that is exceeding resistant-pressure.

 

● Make sure that the power supply is OFF while wiring.

 

●  Take care that short-circuit of the load or wrong wiring may burn or damage the product.

 

● Take care that if applying voltage exceeding the rated range or connecting to AC 

power supply, the product may break or burn.

 

● If power is supplied from a commercial switching regulator, ensure that the frame 

ground (F.G.) terminal of the power supply is connected to an actual ground.

 

● In case noise generating equipment (switching regulator, inverter motor, etc.) is 

used in the vicinity of this product, connect the frame ground (F.G.) terminal of the 

equipment to an actual ground.

 

●  Do not use during the initial transient time (approx. 5 sec.) after the power supply is switched ON.

 

● Do not run the wires together with high-voltage lines or power lines or put them in 

the same raceway. This can cause malfunction due to induction.

 

● The specification may not be satisfied in a strong magnetic field.

 

●  Accuracy of the display and the analogue voltage output is influenced by self-heat-

ing by applying current other than the temperature characteristics. Standby time (5 

min. or more after applying current) should be taken when using the product. 

 

● Extension up to total 10m is possible with 0.3mm

2

 or more, cable. 

 

● Make sure that stress by forcible bend or pulling is not applied directly to the sen-

sor cable joint.

 

● This product is suitable for indoor use only. 

 

● Do not use this product in places having excessive vapor, dust, etc., or where it 

may come in contact with corrosive gas, etc.

 

● Take care that the product does not come in contact with water, oil, grease, or or-

ganic solvents such as thinner, etc., strong acid or alkaline.

 

● Do not drop the product or apply hard shock. This can cause product breakage.

 

● In the case multiple units are installed next to each other, do not allow them to 

contact each other. If the units are in contact, the heat generated by the products 

can cause a change in product characteristics or degradation of the material. Be 

sure to keep a distance of at least 10mm between the products when installing 

multiple units.

 

● This product adopts EEPROM. Settings cannot be done 100 thousand times or 

more because of the EEPROM’s lifetime.

13

SPECIFICATIONS

<Model-wise specifications>

Type

Resin body type

Model No.

FM-252-4

(

-P

)

FM-213-4

(

-P

)

FM-253-4

(

-P

)

FM-214-4

(

-P

)

FM-254-8

(

-P

)

FM-215-8

(

-P

)

Full scale (F.S.) flow rate 

(Note 1)

500mℓ/min

1,000mℓ/min

5ℓ/min

10ℓ/min

50ℓ/min

100ℓ/min

Display flow rate range 

(Note 2)

−550 to 

+550mℓ/min

−1,100 to 

+1,100mℓ/min

−5.5 to 

+5.5ℓ/min

−11 to 

+11ℓ/min

−55 to 

+55ℓ/min

−110 to 

+110ℓ/min

Display resolution

1mℓ/min

0.01ℓ/min

0.1ℓ/min

Integrated flow rate range

±9999999mℓ

±99999.99ℓ

±999999.9ℓ

Specified integrated value

5mℓ

10mℓ

0.05ℓ

0.1ℓ

0.5ℓ

1ℓ

Port size

ø4 push-in

ø8 push-in

Weight

Approx. 50g

Approx. 70g

Type

Aluminum body type

Model No.

FM-255-AR2

(

-P

)

FM-255-AG2-P

FM-216-AR2

(

-P

)

FM-216-AG2-P

Full scale (F.S.) flow rate 

(Note 1)

500ℓ/min

1,000ℓ/min

Display flow rate range 

(Note 2)

−550 to +550mℓ/min

−1,100 to +1,100ℓ/min

Display resolution

1mℓ/min

Integrated flow rate range

±9999999mℓ

Specified integrated value

0.5ℓ

1ℓ

Port size

Rc½

Rc½

Weight

Approx. 155g

<Common specifications>

Type

NPN output type

PNP output type

Model No.

FM-

FM-

-P

Accuracy assurance range 

(Note 3)

Bi-direction: -100 to -3% F.S., +3 to +100% F.S.

One-side direction: +3 to +100% F.S.

Rated pressure range

−0.09 to +0.7MPa

Residual pressure

1MPa

Applicable fluid

Clean air, compressed air and nitrogen gas (Note 4)

Sensing element

Semiconductor type

Supply voltage

12 to 24V DC±10% Ripple P-P10% or less

Current consumption

Normal mode: 60mA or less, ECO mode: 40mA or less

Comparative output

(Comparative output 1 / 2)

NPN open-collector transistor

•  Maximum sink current: 50mA or less

•  Applied voltage: 26.4V DC or less

(between comparative output and 0V)

•  Residual voltage: 2.4V or less

(at 50mA sink current)

PNP open-collector transistor

•  Maximum source current: 50mA or 

less

•  Applied voltage: 26.4V DC or less

(between comparative output and +V)

•  Residual voltage: 2.4V or less

(at 50mA source current)

Output mode

Output OFF mode, window comparator mode, hysteresis mode, integrated output 

mode and integrated pulse output mode

Short-circuit protection

Incorporated

Hysteresis

Window comparator mode: Variable at approx.1 to 8% F.S.

Hysteresis mode: Variable

Analogue voltage output

Output voltage: 1 to 5V, Output impedance: Approx. 1kΩ

Repeatability

Within ±1% F.S.

External input

•  ON voltage: 0 to +0.4V

•  OFF voltage: +5 to +V or Open

•  Input time: 80ms or more

•  ON voltage: +5 to +V

•  OFF voltage: 0 to +0.6V or Open

•  Input time: 80ms or more

Linearity

Within ±3% F.S. (+25°C, secondary atmospheric criteria)

Temperature characteristics

Within ±0.2% F.S. / °C (+15 to +35°C, +25°C criteria)

Pressure characteristics

Within ±5% F.S. (−0.09 to +0.7MPa, +25°C, secondary atmospheric criteria)

Protection

IP40 (IEC)

Ambient temperature

0 to +50°C (no dew condensation allowed), Storage: -10 to +60°C

Ambient humidity

35 to 90% RH or less, Storage: 35 to 90% RH or less

Material

Enclosure: ABS, Body: Polyamide (Aluminum body type: Aluminum)

Switch: EPDM, Display: Acrylic, Mounting screw part (Resin body type): Brass

Cuurent plate / port filter: Stainless steel (used for the gas contact area) 

Sensor tip: Silicone, Gasket: Fluorine rubber 

Grounding method

Floating (Note 5)

Accessory

CN-F15-C1

 (Cable with connector, 1m long): 1 pc.

Notes: 1) Converted to volumetric flow at +20°C and 1 atmospheric pressure (101kPa).

 

2) The display flow rate range is the case when setting to bi-direction at the flow direction setting. When the flow 

direction is set to one-side forward direction or one-side reverse direction, the negative side of the display 

flow rate range shows up to 10% of the full-scale (F.S.).

 

3) Take care that if fluid flows in the vicinity of zero-point which is out of the accuracy assurance range, the in-

stantaneous flow rate value may forcibly display “zero”, or the integrated value may not be counted, or the in-

tegrated pulse output may not be outputted.

 

4) The clean air complies with JIS B 8392-1.1.1 to 5.6.2 and the compressed air complies with JIS B 8392-1.1.1 

to 1.6.2.

 

5) As a variable resistor (clamping voltage: approx. 40V) is connected to the aluminum body type, do not apply 

voltage higher than the rated voltage of the sensor.

14

INTENDED PRODUCTS FOR CE MARKING

 

●  The models listed under “

13

SPECIFICATIONS

” come with CE Marking.

As for all other models, please contact our office.

http://panasonic.net/id/pidsx/global

Overseas Sales Division (Head Office) 

2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan 

Phone: +81-568-33-7861  FAX: +81-568-33-8591

For sales network, please visit our website.

PRINTED IN JAPAN

© Panasonic Industrial Devices SUNX Co., Ltd. 2016 

Summary of Contents for FM-252-4-P

Page 1: ... of the product may fall off 3 WIRING Connection method Insert the cable with connector CN F15 C1 accesso ry into the connector area of this product and mount the connector cover Disconnection method Remove the connector cover and pressing the release lever of the cable with connector pull out the connector Connector cover Note Do not pull by holding the cable without pressing the release lever as...

Page 2: ...ction then conduct key operation or input an external signal For setting the integrated value reset input function refer to CH2 setting in 9 PRO MODE 2 The integrated value will be reset when the power is supplied again at the integrated flow rate display Confirmation of the set value The threshold value of the comparative output 1 and the output mode can be checked while holding down UP key when ...

Page 3: ... Press ON when higher than threshold value ON when lower than threshold value Notes 1 When setting CH2 the threshold value of the comparative output 1 may be reset Therefore confirm the threshold value of the comparative output 1 after setting CH2 2 For CH2 setting mode refer to Output mode in 8 MENU SETTING MODE 3 For teaching function refer to 10 TEACHING FUNCTION Response time setting Sets resp...

Page 4: ... or more cable Make sure that stress by forcible bend or pulling is not applied directly to the sen sor cable joint This product is suitable for indoor use only Do not use this product in places having excessive vapor dust etc or where it may come in contact with corrosive gas etc Take care that the product does not come in contact with water oil grease or or ganic solvents such as thinner etc str...

Reviews: