13
Ref. No. 2C
Procedure 2A
2B
2C
Assembly of Switch and Motor assembly.
1. Attach the quick connect terminal of the white lead wire from the
motor stator with the switch assembly (M+).
2. Apply grease (FLOIL AH-137N-2 / WEWGW2) on the both side and
both end of ribbon cable where insert into the connectors.
NOTE:
Confirm if there is no dust or any foreign substances.
3. Slightly lift the connector up.
NOTE:
Do not pull the connector forcefully. It does not separate from the
other connector.
4. Insert the ribbon cable into the motor stator and the main PCB.
NOTE:
Make sure to handle the ribbon cable gently in order to avoid the
breakage.
5. Insert the quick connect terminal of motor lead wire (black) into the (-)
side of terminal block.
6. Insert the connector of harness into the main PCB.
7. Connect the black lead wire into the (-) side of terminal block and the
read lead wire goes to (+) side of terminal block.
Summary of Contents for EYFMA1B
Page 3: ...3 3 Troubleshooting Guide ...
Page 4: ...4 ...
Page 5: ...5 ...
Page 6: ...6 4 Service Fixture and Adjustment 4 1 Check Parts Identify Procedure ...
Page 7: ...7 ...
Page 8: ...8 ...
Page 16: ...16 7 Schematic Diagram ...
Page 17: ...17 8 Wiring Connection Diagram ...
Page 18: ...18 9 Exploded View and Replacement Parts List 9 1 Exploded View for EYFMA1B ...
Page 20: ...20 9 3 Exploded View for EYFMA1J ...