10
Ref. No. 1C
Procedure 1A
1B
1C
Removal of Housing.
1. Remove nine housing screws.
2. Then open the housing A and B.
NOTE:
When opening the housings, make sure that the main PCB is on the
housing A.
If the main PCB sticks in the housing B and pull it out from the hous-
ing A, the ribbon cable may be defected.
Ref. No. 1D
Procedure 1A
1B
1C
1D
Removal of Ribbon cable (FPC).
1. Slightly lift up the connector.
NOTE:
Do not pull the connector firmly because it is not able to take out
completely.
2. Take out the ribbon cable.