background image

GB9

WARNING!

• Do not use this device for any purpose other than therapy.

- Doing so may result in an accident or injury.

• Do not use this device simultaneously with other medical devices or in combination with 

medicinal ointments (or sprays).
- Doing so may cause an accident or health problems.

• Do not immerse the pads into water, splash water on the pads, or take a bath with the product 

in operation.

• Do not use the product where there is high humidity, such as in a bathroom.

- Doing so will result in a strong electric shock.

• During operation, keep the pads away from metallic objects, such as belt buckles or 

necklaces.
- Doing so may result in a strong electric shock or burns.

• Do not allow children or persons who are unable to express themselves to use the device.
• Also do not allow persons who are unable to operate the device by themselves to use the 

device.
- Doing so may result in an accident or injury.

GB8

• Attach the pads to the skin so they do not overlap.
• Do not bend the pads.
• Try to avoid touching the adhesive surface with your fingers.
• If the pads lose their adhesive strength, clean them. (See page GB15.)
• Do not use the pads when they are wet.

Shake off any water and air-dry the adhesive surfaces before using the pads.

Handling the pads

DANGER!

• Never use the product in combination with the following medical devices:

(1) Implanted electronic medical device, such as a pacemaker
(2) Life support medical device, such as a heart-lung machine
(3) Attached medical device, such as an electrocardiograph
- Doing so may cause an accident or noticeable bodily impairment.

WARNING!

• The following persons should consult with a physician before using this product and when 

undergoing treatment:
  (1) Those with an acute illness
  (2) Those with malignant tumors
  (3) Those with an infectious disease
  (4) Those who are pregnant, menstruating, or who have recently given birth
  (5) Those with heart problems
  (6) Those having a body temperature (fever) of 38

°

C or higher

(Example: when feeling weak or having severe symptoms of acute inflammation, such as 
malaise, chills, or fluctuating blood pressure)

  (7) Those who are anemic
  (8) Those with an abnormal skin condition (infectious disease or injury)
  (9) Those suffering from abnormally high blood pressure (180 mmH

g

 or higher)

(10) Those requiring rest or in physically poor shape
(11) Those with acute pain, such as backbone fracture, sprain, torn muscle, etc.
(12) Those with sensory loss caused by advanced peripheral circulatory disorders, such as 

due to diabetes

(13) Besides the above, those feeling physical discomfort
- Failure to do so may result in an accident or health problems.

• Be sure to turn off the power before attaching, reattaching or detaching the pads.

- Failure to do so may result in a strong electric shock or burn.

• Do not wrap the cord while the pads are attached to your skin.
• Wrap the cord after attaching the pads to the pad storage plate.

- Failure to do so may result in injury.

• Do not use the device on areas close to the heart, on the face or head, in the mouth, genitals, 

or where there is a skin disease.
- Doing so may cause an accident or health problems.

• Do not use the device while you are asleep.

- Doing so may cause an accident or injury, such as with the cord becoming entangled around 

your neck. Furthermore, the pads may attach to another part of the body (near the heart, on 
the face or head, in the mouth, genitals, or where there is a skin condition) and cause an 
accident or health problems.

Summary of Contents for EW6011

Page 1: ...ce dispositif veuillez lire entièrement ces instructions et rangez soigneusement ce manuel pour le consulter par la suite Prima di mettere in funzione questo apparecchio leggere completamente le presenti istruzioni e conservare questo manuale per líutilizzo futuro Antes de utilizar este dispositivo lea completamente estas instrucciones y conserve este manual para futura referencia ѕеред использова...

Page 2: ...ckerung verbessern die Durchblutung und bewirken deshalb in der Regel auch eine deutliche Schmerzlin derung Einfach die Panasonic Pflaster auf die Körperpartien kleben die Sie behandeln möchten Die Pflaster liegen flach auf der Haut und beeinträchtigen nicht Die Steuerung der Panasonic Therapiereize erfolgt ganz einfach mittels Handbedienung Stromversorgung 2 1 5V Alkali Batterien Typ LR03 AAA Bed...

Page 3: ...edeutet dass elektrische und elektronische Produkte am Ende ihrer Lebensdauer vom Hausmüll getrennt entsorgt werden müssen Bringen Sie bitte diese Produkte für die Behandlung Rohstoffrückgewinnung und Recycling zu den eingerich teten kommunalen Sammelstellen bzw Wertstoffsammelhöfen die diese Geräte kostenlos entgegennehmen Die ordnungsgemäße Entsorgung dieses Produkts dient dem Umweltschutz und v...

Page 4: ...ents of the package Main unit Replacement pads 2 Storage case LR03 AAA batteries 2 Pad storage plate 1 GB2 PARTS IDENTIFICATION Main unit Cord take up switch side Slide switch used when storing the cord Battery cover rear Power strength dial Program location selection button Manual operation selection button Stimulation mode switching button Cord opening Cord end line red Cord ...

Page 5: ...th batteries with two fresh batteries of the same type Battery life may shorten if the room temperature is low Discard used batteries properly Handling the batteries When the treatment stimulus feels weak or when the output stops before 15 minutes of use the batteries may have become exhausted Replace them with fresh batteries When to replace the batteries CAUTION Be sure to observe the precaution...

Page 6: ...ymmetrically to the left and right shoulders with your backbone in the middle Arms and legs Arm Attach the pads one above the other on the arm Waist Attach the pads symmetrically to the left and right waist with your backbone in the middle Leg Attach the pads one above the other on the calf Both knees at the same time Attach the pads below the knees Soles of the feet Emphasis on one side Attach th...

Page 7: ... with a physician before using this product and when undergoing treatment 1 Those with an acute illness 2 Those with malignant tumors 3 Those with an infectious disease 4 Those who are pregnant menstruating or who have recently given birth 5 Those with heart problems 6 Those having a body temperature fever of 38 C or higher Example when feeling weak or having severe symptoms of acute inflammation ...

Page 8: ... between O and 2 for around 3 minutes to allow your body to adjust to the sensation then increase the strength to the desired level Persons who have sensitive skin should shorten the time and start from a low setting The power will automatically turn off approximately 15 minutes after it is turned on The power will automatically turn off approximately 15 minutes after it is turned on even if the p...

Page 9: ...imultaneously at the pad positions Switching the stimulus mode Manual treatment GB12 Using the Low Frequency Muscle and Nerve Stimulator cont Neck Mainly rubs to gently loosen the neck Shoulder Firmly taps to loosen the shoulders Joint Relieves joint pain with fine vibrations Waist Loosens the large waist muscles with a grasping massage Arm Leg Taps and grasps to loosen muscles Sole Mainly taps to...

Page 10: ...3 Shake off any water place the pads with their adhesive surfaces facing up let the surfaces air dry and then attach the pads to the pad storage plate After washing the pads do not wipe the adhesive surfaces with a tissue paper or cloth Doing so may result in the tissue paper or cloth sticking to the adhesive surfaces If they become stuck to the adhesive surfaces by accident do not forcibly peel t...

Page 11: ...stimulation directly massages the muscles calms excited nerves and improves blood circulation Q1 How long should the massage be A1 The basic treatment time for one position is approximately 15 minutes If this time is exceeded the result may be detrimental Q2 How many places can be treated A2 As many places as you desire can be treated in one day However please observe the limit of 15 minutes for o...

Page 12: ...am 61 13 VMax 8 0 1 5 mAMax Joint program 55 11 VMax 8 0 1 5 mAMax Waist program 62 12 VMax 8 0 1 5 mAMax Calve program 61 13 VMax 8 0 1 5 mAMax Arches program 61 13 VMax 8 0 1 5 mAMax Length of impulse 300 µs Impulse polarity automatic alternation Infinitely adjustable stimulation frequency Tapping impulse 3 5Hz Pressing impulse 40Hz Kneading impulse 50Hz Rubbing impulse 100Hz The technical data ...

Page 13: ...such as a heart lung machine 3 Attached medical device such as an electrocardiograph Doing so may cause an accident or noticeable bodily impairment Never use the product while connected to a high frequency surgical appliance as this might lead to burns under the pads Never use a short wave or micro wave therapy appliance in the immediate vicinity as this might lead to the output fluctuation WARNIN...

Page 14: ...ating the model EW6011 b Over the frequency range 150 kHz to 80 MHz field strengths should be less than 3 V m GB22 The model EW6011 needs special precautions regarding EMC and needs to be used according to the following EMC information Portable and mobile RF communications equipment can affect the model EW6011 Accessories WARNING The use of accessories other than those specified may results in inc...

Page 15: ...2 80 MHz to 800 MHz d 1 2 P 0 12 0 38 1 2 3 8 12 800 MHz to 2 5 GHz d 2 3 P 0 23 0 73 2 3 7 3 23 Information on Disposal for Users of Waste Electrical Electronic Equipment private households This symbol on the products and or accompanying documents means that used electrical and electronic products should not be mixed with general household waste For proper treatment recovery and recycling please ...

Reviews: